WARNING
!
CENTRIFUGAL FILTER
Installation and
Operation Manual
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
Notice to Installer
This manual contains important information about the installation, operation
& safe use of this product. Once the product has been installe this manual
must be given to the owner / operator of this equipment.
SAFETY INFORMATION
1. The Waterco MultiCyclone Plus/Ultra lters are designed to work with water at a temperature
> than 0ºC and < than 45ºC. The lter should never be operated outside of these temperatures
or damage may occur.
2. The installation should be carried out in accordance to local safety standards and bylaws.
3. Any modication of the lter requires the prior consent from Waterco. Original replacement
parts and accessories authorised by the manufacturer ensure a high level of safety. Waterco
assumes no liability for the damage and injuries caused by unauthorised replacement parts
and accessories.
4. The user should make sure that the installation is carried out by qualied authorised persons
and that these persons have rst carefully read the following instructions.
5. The operating safety of the lter is only guaranteed if the installation and operation
instructions are correctly followed.
6. In the event of defective operation or fault, contact Waterco or its nearest authorised service
agent.
7. To reduce the risk of injury, do not permit children to use this product.
8. Incorrectly installed equipment may fail, causing severe injury or property damage.
9. Chemical spills and fumes can weaken Swimming Pool/Spa equipment. Corrosion can
cause lters and other equipment to fail, resulting in severe injury or property damage. Do
not store pool chemicals near your equipment.
SAFTEY INFORMATION ------------------------------------------ 01
MULTICYCLONE PLUS/ULTRA ---------------------------------- 02
MULTICYCLONE TOTAL HEAD LOSS CURVE ------------------ 04
INSTALLATION ---------------------------------------------------- 04
START UP PROCEDURES ---------------------------------------- 06
MULTICYCLONE PLUS/ULTRA FILTER MAINTENANCE ------ 07
INSUFFICIENT WATER PRESSURE ------------------------------ 07
FILTER CARTRIDGE MAINTENANCE ---------------------------- 08
GENERAL MAINTENANCE GUIDE ------------------------------ 09
WINTERISING ----------------------------------------------------- 09
TROUBLESHOOTING GUIDE ------------------------------------ 10
WARRANTY ------------------------------------------------------- 10
I pg 02
MultiCyclone Plus/Ultra
MULTICYCLONE PLUS/ULTRA
MultiCyclone Plus/Ultra combines centrifugal and cartridge ltration into one streamlined
housing, creating an ultra compact ltration system.
• Dual stage ltration.
• Minimal maintenance.
• Save water and energy.
• 12/16 hydrocyclones.
• Plus 40ft2 & 75ft2 Ultra pleated lter cartridge.
Dual stage filtration
Incoming water tangentially enters its multiple
hydrocyclones, generating a strong centrifugal effect.
Approximately 80% of the incoming dirt load is spiralled
down to its clear sediment chamber. The outgoing water
is nally polished via its inbuilt cartridge lter, producing
crystal clear water.
Simple maintenance
MultiCyclone Plus/Ultra’s sediment chamber is easily
cleaned by opening its purge valve. Only 15 litres of water
is discharged.
Ultra compact filtration
MultiCyclone Plus/Ultra’s streamlined design means the
entire ltration system can be installed vertically, reducing
the footprint of the equipment pad. Additionally, minimal
pipework reduces ltration system’s overall head loss.
Extended filter capacity
The MultiCyclone Plus/Ultra’s centrifugal section lter
pre-lters up to 80% of the incoming dirt load before it
reaches the lter cartridge, magnifying the capacity of its
lter cartridge by up to 5 times. MultiCyclone Plus has
a ltration capacity equivalent to a 200 ft
2 & Ultra 375ft2
cartridge lter.

Specyfikacje produktu

Marka: Waterco
Kategoria: Waterfilter
Model: MultiCyclone Ultra MC16

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Waterco MultiCyclone Ultra MC16, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Waterfilter Waterco

Instrukcje Waterfilter

Najnowsze instrukcje dla Waterfilter

PUR

PUR PPT710W Instrukcja

2 Października 2024
PUR

PUR PPT700W Instrukcja

2 Października 2024
Oliveri

Oliveri FS7025 Instrukcja

2 Października 2024
Hydor

Hydor Filter Instrukcja

2 Października 2024
Oliveri

Oliveri FS7075 Instrukcja

2 Października 2024
T.I.P.

T.I.P. TFP 5000 UV 9 Instrukcja

1 Października 2024
Haier

Haier HRO100C1-SU1 Instrukcja

22 Września 2024
Baracuda

Baracuda BSCF150 Instrukcja

19 Września 2024