TECHNICAL DATA
MODEL VT-80360
SKU 23165
INPUT POWER AC: 220-240V, 50/60 Hz
RATED LOAD Max. 1200W
300W +LED
TIME DELAY Min. 10sec ±3sec
Max. 12min ±1min
DETECTION
RANGE 36
DETECTION
DISTANCE 1-8m (Radius), Adjustable
DETECTION
MOVING SPEED 0.6-1.5m/s
WORKING
TEMPERATURE -20°C to +40°C
POWER
CONSUMPTION Approx, 0.5W
AMBIENT LIGHT <3-2000 LUX (Adjustable)
INSTALLATION
HEIGHT 1.5-3.5m
POWER
CONSUMPTION approx w0.9
DETECTION
MOTION SPEED 0.6-1.5 m/s
IP RATING IP20
HF SYSTEM 5.8Ghz CW Radar, ISM
Band
DIMENSION Ø80x66.6 mm
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions
carefully before starting the installation and keep this manual handy for future reference. If you have any another
query, please contact our dealer or local vendor from whom you have purchased the product. They are trained
and ready to serve you at the best. The warranty is valid for 5 years from the date of purchase. The warranty
does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no
warranty against damage to any surface due to incorrect removal and installation of the product.
V-TAC LED
RANGE (UPTO 400W)
COMPATIBLE WITH
This marking indicates that this prod-
uct should not be disposed of with
other household wastes.
Caution, risk of electric shock.
FUNCTION
WARNING
1. Please make sure to turn o the power before starting the installation.
2. Installation must be performed by a qualified electrician.
3. For Indoor use only
1. Can identify day and night: It can work in the daytime and at night when it is adjusted on the
sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the
“3” position (min). As for the adjustment pattern, please refer to the testing pattern.
2. SENS adjustable: It can be adjusted according to using location. The detection distance of low
sensitivity could be only 2m and high sensitivity could be 16m which fits for large room.
3. Time-Delay is added continually: When it receives the second induction signals within the first
induction, it will restart to time from the moment.
4. Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum time
is 10sec±3sec. The maximum is 12min±1min.
NOTE: the high-frequency output of the HF sensor is
<0.2Mw- that is just one 5000th of the transmission power
of a mobile phone or the output of a microwave oven, the
baby can not touch it
INSTALLATION
1. Swing the plastic cover a little and adjust time and LUX knob.
2. Unload the transparent vinyl cover, loose the screws in the connection terminal, and then
connect the power to connection terminal of sensor according to connection-wire diagram.
3. Fold the metal spring of the sensor upwards, until they are in “I” position with sensor, and
then put the sensor into the hole or installation box which is on the ceiling and has the similar
size with the sensor. Releasing the spring, the sensor will be set in this installation position.
4. Aer finishing installing, turn on the power and then test it
STEP 1
STEP 2 STEP 3
Turn the LUX knob clockwise on the maximum (sun). Turn the SENS knob clockwise on
the maximum (+). Turn the TIME knob anti-clockwise on the minimum (10s).
When you switch on the power, the light will be on at once. And 10sec±3sec later the
light will be o automatically. Then if the sensor receives induction signal again, it can
work normally.
When the sensor receives the second induction signals within the first induction, it will
restart to time from the moment.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
CONNECTION-WIRE DIAGRAM
TEST
Note: When testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor could not work!

Specyfikacje produktu

Marka: V-TAC
Kategoria: Bewegingsdetector
Model: VT-80360

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z V-TAC VT-80360, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Bewegingsdetector V-TAC

V-TAC

V-TAC VT-8092 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-8091 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81014 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81013 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81012 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81011 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81010 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81009 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-81007 Instrukcja

8 Października 2024
V-TAC

V-TAC VT-80360 Instrukcja

8 Października 2024

Instrukcje Bewegingsdetector

Najnowsze instrukcje dla Bewegingsdetector

Maxsa

Maxsa 40234 Instrukcja

9 Października 2024
Maxsa

Maxsa 43218 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-233 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-219 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-232 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-231 Instrukcja

9 Października 2024
JUNG

JUNG BTLC17181244 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182250 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17181255 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182259 Instrukcja

8 Października 2024