Instrukcja obsługi Mikrotik CRS328-4C-20S-4S

Mikrotik przełącznik CRS328-4C-20S-4S

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Mikrotik CRS328-4C-20S-4S (11 stron) w kategorii przełącznik. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/11
CRS328-4C-20S-4S+RM
Quick start
Mount unit in a rackmount cabinet or place on the flat surface (see “ ”).
Mounting
Connect two powering units to the AC source using power cords.
The Initial connection has to be done via the Ethernet cable, using the MikroTik Winbox utility.
Use Winbox to connect to the default IP address of 192.168.88.1 from any port, with the username admin
and no password.
We recommend clicking the “Check for updates” button and updating your RouterOS software to the latest
version to ensure the best performance and stability.
Set up your password to secure the device.
Powering
The device accepts powering from two IEC connectors. AC input range 100-240 V .
The power consumption under maximum load can reach 43 W.
Booting process
The device supports booting RouterOS (for routing and switching configuration) or SwOS (for only using as a
switch). By default, the device will boot RouterOS, but you can reboot into the other operating system in the
following ways:
From SwOS: In the System menu, click the “Boot RouterOS” button on the bottom of the page.
From RouterOS: in the System, RouterBOARD menu, click “Settings” and there select “Boot OS”.
It is also possible to select the OS and configure other boot settings via the serial console menu.
Configuration
Full RouterOS and SwOS documentation is located here: http://mt.lv/help
This device is not preconfigured other than an IP address on the bridge interface. You can connect from any port,
as all ports are switched together by default. Another configuration has to be applied according to the
documentation manual linked above.
The Initial connection has to be done via the Ethernet cable, using the MikroTik WinBox utility. WinBox should be
used to connect to the default IP address of 192.168.88.1 from any port, with the username admin and no
password.
For recovery purposes, it is possible to boot the device for reinstallation, see Buttons and jumpers.
In case the IP connection is not available, the WinBox utility can also be used to connect to the MAC address of the
the device. Applies only when device has booted RouterOS.
The device is equipped with an RJ45 serial port, set by default to 115200 bit/s, 8 data bits, 1 stop bit, no parity.
Standard RJ45 to COM cable can be used, pinout can be found here: http://mt.lv/console
Extension slots and ports
20 SFP ports.
4 SFP+ ports, which accept both 1.25 Gb SFP and 10 Gb SFP+ modules.
4 combo ports, consisting of four twisted pair (T) sockets and four SFP sockets (F).
RJ45 serial port.
Please visit wiki pages for MikroTik SFP module compatibility table:
https://wiki.mikrotik.com/wiki/MikroTik_SFP_module_compatibility_table
See mikrotik.com/products for the latest version of this document. Page 1, Document #52503 Modified on: 07.OKT.2019
Combo ports
The four combo interfaces each have two physical connectors of which the only one can be used at the same time.
The ports will be automatically represented as combo1-4 in the RouterOS. It is possible to select which physical
port will be used in RouterOS software Ethernet menu. If left to default “auto”, and both F/T have cables plugged in,
SFP will take priority. For example, if you have plugged an Ethernet cable into the 1T port and an SFP module in
the 1F port, you will have to choose in RouterOS which one to use. Double click the respective combo interface in
RouterOS GUI to see which socket is used.
Mounting
The device is designed to use indoors and it can be mounted in a rackmount enclosure using provided rack
mounts, or it can be placed on the desktop. Please attach rubber pegs on the bottom of the router if the desired
placement is on the flat surface or use a Phillips screwdriver to attach rackmount ears on both sides of the device if
designated use is for rackmount enclosure:
1. Attach rack ears to both sides of the device and tighten four screws to secure them in place, as
shown in the picture.
2. Place the device in a rackmount enclosure and align with the holes so that the device fits
conveniently.
3. Tighten screws to secure it in place.
The IP rating scale for this device is IPX0. The device has no protection from water contamination, please ensure
the placement of the device in a dry and ventilated environment.
Mounting and configuration of this device should be done by a qualified person. We recommend using Cat6 cables
for our devices.
See mikrotik.com/products for the latest version of this document. Page 2, Document #52503 Modified on: 07.OKT.2019
Buttons and jumpers
Reset button
Hold this button during boot time until LED light starts flashing, release the button to reset RouterOS
configuration (total 5 seconds).
Keep holding the button for 5 more seconds until LED turns off, then release it to make the RouterBOARD
look for Netinstall servers (total 15 seconds). The first Ethernet port is used for the Netinstall process. See
RouterOS documentation about using the Netinstall recovery utility.
Regardless of the above option used, the system will load the backup RouterBOOT loader if the button is pressed
before power is applied to the device. Useful for RouterBOOT debugging and recovery.
Mode button
The action of the mode button can be configured from RouterOS software to execute any user-supplied RouterOS
script. For configuration, use the menu /system routerboard mode-button
Specifications
For more information about this product, specifications, pictures, downloads and test results please visit our web
page: https://mikrotik.com/product/crs328_4c_20s_4s_rm
Operating system support
The device supports dual boot SwOS software version 2.9 and RouterOS v6. The specific factory installed version
number is indicated in the RouterOS menu /system resource. Other operating systems have not been tested.
See mikrotik.com/products for the latest version of this document. Page 3, Document #52503 Modified on: 07.OKT.2019


Specyfikacje produktu

Marka: Mikrotik
Kategoria: przełącznik
Model: CRS328-4C-20S-4S
Kolor produktu: Biały
Napięcie wejściowe AC: 100 - 240 V
Wysokość produktu: 200 mm
Szerokość produktu: 443 mm
Głębokość produktu: 44 mm
Maksymalne zużycie mocy: 43 W
Wielkość pamięci flash: 16 MB
Pojemność pamięci wewnętrznej: 512 MB
Procesor wbudowany: Tak
Standardy komunikacyjne: IEEE 802.1Q, IEEE 802.3ad
Obsługa PoE: Nie
Zakres temperatur (eksploatacja): -20 - 60 °C
Układ: 1U
Taktowanie procesora: 800 MHz
Przewody: Prąd przemienny
Diody LED: Tak
Ilość jednostek zasilania: 1
Obsługa sieci VLAN: Tak
Możliwości montowania w stelażu: Tak
Typ przełącznika: Zarządzany
Obsługa 10G: Tak
Wielkość tabeli adresów: 16000 wejścia
Przepustowość rutowania/przełączania: 128 Gbit/s
Lista kontrolna dostępu (ACL): Tak
Przełącznik wielowarstwowy: L2/L3
Prędkość przekazywania: 95.2 Mpps
Zgodny z Jumbo Frames: Tak
Rozszerzenie Jumbo Frames: 10218
IGMP snooping: Tak
Zasilacz dołączony: Tak
Ilość slotów Modułu SFP+: 4
Port konsoli: RJ-45
Agregator połączenia: Tak
Zestaw do montażu haków: Tak
Dublowanie portów: Tak
Kontrola wzrostu natężenia ruchu: Tak
Liczba portów SFP Combo: 4
Ilość slotów Modułu SFP: 20

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mikrotik CRS328-4C-20S-4S, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje przełącznik Mikrotik

Instrukcje przełącznik

Najnowsze instrukcje dla przełącznik

INOGENI

INOGENI CAM230 Instrukcja

14 Stycznia 2025
Luxul

Luxul XMS-5248P Instrukcja

14 Stycznia 2025
Luxul

Luxul AMS-2624P Instrukcja

14 Stycznia 2025
Luxul

Luxul XGS-1005 Instrukcja

14 Stycznia 2025
Luxul

Luxul AGS-1008M Instrukcja

14 Stycznia 2025
Luxul

Luxul XMS-1208P Instrukcja

14 Stycznia 2025
Luxul

Luxul XMS-7048P Instrukcja

14 Stycznia 2025
Luxul

Luxul AMS-2600 Instrukcja

14 Stycznia 2025