Instrukcja obsługi Haws 7501
Haws
system prysznicowy
7501
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Haws 7501 (8 stron) w kategorii system prysznicowy. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/8
03 20/ Model 7501/7501T/7501T240 of 1 Page 8
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E- mail: haws@hawsco.com website: www.hawsco.com
No. 0002080045 (1 ) 8
Model 7501/7501T/7501T240
Portable Eyewash/Portable Eyewash with Heater
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any
goods, or part thereof, which shall appear to the Company upon inspection to be of
defective material or not of first class workmanship, provided that claim is made in writing
to Haws within a reasonable period after receipt of the product. Where claims for defects
are made, the defective part or parts shall be delivered to the Company, prepaid, for
inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or
for any expense connected therewith made by the owner or his agents, except upon
written authority fr m HAWS, Sparks, Nevada. HAWS will not be liable for any damages o
caused by defective materials or poor workmanship, except for replacements
, as
provided above. Buyer agrees that Haws has made no other warranties either expressed
or implied in addition to those above stated, except that of title with respect to any of the
products or equipment sold hereunder and that HAWS shall not be liable for general,
special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for
the purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF
THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1- - - 800 766 5612
FOR CUSTOMER SERVICE: 1- - - 888 640 4297
03 20/ Model 7501/7501T/7501T240 of 2 Page 8
CAUTION : A GROUND FAULT DEVICE MUST BE USED WITH THIS HEATING DEVICE.
ATTENTION : CE PRODUIT DOIT ÊTRE UTILISÉ AVEC UNE PROTECTION DE MISE À LA
TERRE.
RECOMMENDED TOOLS: Three 1/4" diameter anchors suitable for supporting filled eyewash
(approximately 80 pounds), and tools needed to install these anchors.
LOCATION OF UNIT: The Model 7501/7501T/7501T240 eyewash units should be installed in
close proximity to potential accident areas. It should be clearly identified, free from obstructions
and easily accessible. IMPORTANT: Model 7501 eyewash units shall be (non-insulated)
protected from freezing. Models 7 7501/7501T/ 501T240 shall not have internal
temperatures exceeding 38 ⁰C (100⁰F) and shall not be exposed to ambient temperatures
exceeding 38°C (100°F). Be careful of direct sunlight.
ELECTRICAL CONNECTIONS: (reference manual supplied with heating blanket)
Model 7501T – 120VAC, 60 Hz, 1.38A three. Requires a -prong outlet and is supplied with a
heavy-duty 8 foot power cord with GFCI plug. Unit is suitable for installation and use in
NEMA/TYPE 3R areas. Must be used with NEMA/TYPE 3R certified covered outlet (not
supplied). DURING POTENTIAL FREEZING PERIODS INSURE THAT UNIT IS CONNECTED
TO A CONTINUOUS POWER SUPPLY.
Model 7501T240 – VAC, 240 50/60 Hz, 0.64A. Requires a 240VAC outlet and is not supplied
with a power cord which must be installed by the user. Unit is suitable for installation and use in
NEMA/TYPE 4 areas. Power connection to be per local code using f ible conduit orlex cable
rated NEMA/TYPE 4 – no rigid connection permitted. A MUST BE PROTECTED BY Class A
GROUND FAULT CIRCUIT INTERRUPTER (GFCI). DURING POTENTIAL FREEZING
PERIODS INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS POWER SUPPLY.
AMBIENT TEMPERATURE RATINGS:
MODEL 7501: 60°F (16°C) TO 100° (38°C)
MODEL 7501T: -22°F (- C 30° ) TO 100°F (38°C)
MODEL 7501T240: - - 30°F ( 35°C) TO 100°F (38°C)
03/20 Model 7501/7501T/7501T240 of 3 Page 8
INSTALLATION INSTRUCTIONS
NOTE: Instructions apply to all models unless otherwise specified.
STEP 1: Models 7501T/7501T240: Install the blanket and connect to power source per the
Installation Manual provided with the heating blanket.
CAUTION – DO NOT ENGERIZE THE HEATING BLANKET POWER SOURCE
UNTIL THE EYEWASH IS FILLED WITH FLUSHING FLUID (UP TO FILL LINE).
NOTICE: MODEL 7501T240 REQUIRES MINIMUM NEMA/TYPE 4 COMPLIANT
EQUIPMENT. ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO
NEC / CEC CODE USING FLEXIBLE CONDU CABLE RATED IT OR FOR
NEMA/TYPE 4 – NO RIGID CONNECTION PERMITTED.
STEP 2: Model 7501: Mount unit to wall utilizing “J” bracket (supplied). Note: ¼” mounting
hardware not supplied. See Installation Drawing on Page 7 of 8.
Model 7501T/7501T240: Mount eyewash unit to wall utilizing “J” bracket and three
aluminum spacers (supplied). Locate one aluminum spacer behind each bolt hole in
“J” bracket. Note: ¼” mounting hardware is not supplied. See Installation Drawing on
Page 8 of 8.
STEP 3: Make sure portable eyewash unit is nt to back and left to right before level from fro
securing bracket to wall. Eyewash nozzles should be between 33 inches (83.8 cm)
and 53 inches (164.6 cm) above the floor when eyewash arm is in the active
(lowered) position (See Installation es 7 and 8 of 8Drawings, pag ).
Filled eyewash unit is heavy (approximately 80 pounds). Wall bracket anchors
(Quantity 3 not supplied) must be strong enough to support the filled eyewash and -
the weight of a worker leaning on eyewash.
STEP 4: Fill up to fill line (see important note above). Requires 8.75 gallons (max) of water,
(make sure that no debris or contaminants of any kind are present in the flushing
fluid). Make sure unit is level from front to back and left to right. If installed as
i -ndicated, eyewash unit will provide 15 minute duration of flow. Add Antimicrobial
Preservative Haws Model 9082 as directed (see step 2 under Maintenance Section).
IMPORTANT – DO NOT FILL PAST WATER FILL LINE AS LEAKAGE WILL
OCCUR AT THE EYEWASH HEADS.
STEP 5: : Model 7501T/7501T240 Energize power source and verify operation of heating
blanket. et Ope (Refer to heating blank ration Manual)
STEP 6: Take proper precautions to help prevent the growth of potentially harmful bacteria in
eyewash tanks. (Refer to Maintenance Instructions)
IMPORTANT SAFETY NOTICE
THE NATIONAL ELECTRICAL CODE REQUIRES GROUND PROTECTION ON EACH -FAULT EQUIPMENT
HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER
INSTALLATION, CIRCUIT BREAKERS SUCH AS ARE D QO SQU -EPD AND QOB-EPD OR EQUIVALENT, WITH A
30mA TRIP LEVEL, SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER REFERENCE
IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTERNATIVE DESIGNS PROVIDING
COMPARABLE LEVELS OF GROUND N MAY ALSO BE ACCEPTABLE. -FAULT PROTECTIO
Specyfikacje produktu
Marka: | Haws |
Kategoria: | system prysznicowy |
Model: | 7501 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Haws 7501, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje system prysznicowy Haws
25 Września 2024
25 Września 2024
25 Września 2024
25 Września 2024
25 Września 2024
25 Września 2024
25 Września 2024
Instrukcje system prysznicowy
- system prysznicowy Ikea
- system prysznicowy Hozelock
- system prysznicowy Dimplex
- system prysznicowy Delta
- system prysznicowy Fieldmann
- system prysznicowy Hansgrohe
- system prysznicowy Miomare
- system prysznicowy Juno
- system prysznicowy Schütte
- system prysznicowy Omnires
- system prysznicowy Sani-Lav
- system prysznicowy Fala
- system prysznicowy Pulse ShowerSpas
- system prysznicowy BMI
- system prysznicowy ECOstyle
- system prysznicowy Curaqua
- system prysznicowy Belanger
Najnowsze instrukcje dla system prysznicowy
8 Października 2024
8 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
7 Października 2024
2 Października 2024