Instrukcja obsługi Dormakaba TS93 GSR


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Dormakaba TS93 GSR (12 stron) w kategorii samozamykacz. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
TS93 GSR/EMF PT2
Surface Applied Closer
Push side track mount and coordinator system
Installation instructions
08281031 – 08-2019
| | EN
2TS93 GSR Surface Applied Closers 08-201908281031
dormakaba TS93 GSR/EMF PT2 Installation Instructions
Table of Contents
Table of contents
1  Technical specifications 3
1.1 Overview 3
1.2 Size selection chart 3
1.3 Tools recommended 3
1.4 Surface closer system 4
1.5 Handing the door 4
2 Installation instructions 5
2.1 Installing the back plate 5
2.2 Installing the surface closer 5
2.3 Installing the slide channel 6
2.4 Installing the main arm 6
2.5 Secure main arm 7
2.6 Installing the coordinator system 8
2.7 Installing conduit for EMF 8
2.8 Installing coordinator system (continued) 9
2.9 Wiring the EMF 9
3 Adjustments 10
3.1 Adjust closing speeds: sweep, latch, backcheck,
delayed action 10
3.2 Adjust optional hold open 10
3.3 Adjust spring force 11
4 Install covers 11
dormakaba TS93 GSR/EMF PT2 Installation Instructions
08281031 08-2019TS93 GSR Surface Applied Closers 3
Technical specifications
1  Technical specifications
. Overview
Door Width
Closer Interior/
Exterior
1'-3"
min.
2’-6"
max.
3’-0”
max.
3’-6”
max.
4’-0”
max.
4’-6”
max.
5’-0”
max.
TS9315 Interior • NA NA
TS9356 Interior NA NA NA NA •
Caution: sex nuts are required for attachment of
components to unreinforced doors and to wood
or plastic faced composite type fire doors, unless
an alternative method is identified in the
individual door manufacturer’s listings.
Maximum door opening degree is 175°.
Minimum door width is 23”.
Hold open range is from 80° to 130° with optional
hold open kit.
Arrows on closer mounting plate point upward.
A carry bar should be installed to insure that the
active door is opened enough for the inactive
door to close.
Recommended carry bars:
DORMA carry bar MK-397 (up to 3’-6” wide door)
DORMA carry bar MK-398 (3’-6” and wider door)
Installation instructions are included with carry
bar.
Follow included template to properly prepare
door and frame for all accessories of the closer
installation.
Know the swing of the door which is being
installed prior to installation.
Make sure door efficiently operates prior to
installing closer.
Verify closer spring size prior to installation.
Table 
Table 
Drill bits: Pozidriv PZ-2 2.5mm, 3mm, 5mm hex key
Metal: No. 21 & 10-32 tap #2 Phillips screwdriver 1/2” box wrench
Wood: 1/8” 3/16” flat head screwdriver 10” adjustable wrench
. Size selection chart
. Tools recommended
GSR/EMF PT 2 (Active door hold open only or inactive &
active hold open together)
The GSR/EMF T 2 incorporates an electric hold open
mechanism in both door leaves. This enables both
leaves to be held open when the inactive door is placed
in the preselected hold open position and also enables
the active door to be held open independently when the
inactive door is in the closed position. Both doors will
close in sequence (inactive first) from any point upon
signal from the fire alarm system or when electrical
current is interrupted.


Specyfikacje produktu

Marka: Dormakaba
Kategoria: samozamykacz
Model: TS93 GSR

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Dormakaba TS93 GSR, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje samozamykacz Dormakaba

Inne instrukcje Dormakaba