Instrukcja obsługi Viking K-1770-3-EWP


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Viking K-1770-3-EWP (8 stron) w kategorii System kontroli dostępu. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
Vandal Resistant Entry Phones with Built-In
Keypad and 125KHz Proximity Card Reader
The K-1770-3 Series entry phones provide a tough and
attractive handsfree phone for commercial, apartment, and
residential door entry or applications requiring a vandal
resistant speaker phone with built-in 125 KHz Proximity Card
Reader. The card reader outputs industry standard 26-bit
Wiegand data, allowing it to be used with a doorViking ES-1
controller or any controller compatible with 26-bit Wiegand
format. The K-1770-3 Series entry phones are available in
two attractive finishes: “brushed stainless steel” and oil
rubbed bronze”.
When the “Call” button is pressed, the returns dialK-1770-3
tone. The keypad may then be used to dial any number. If
no Touch Tone is entered within 8 seconds, CPC is detected,
a busy signal is detected, or the programmable maximum call
time has elapsed, the will automatically disconnect.K-1770-3
Alternatively, the may be disconnected by pressingK-1770-3
the “Call” button again. The comes complete withK-1770-3
a standard, flush mount, rough-in box. In addition, an optional
VE-6x7 weather resistant, surface mount box is available (see
DOD 424).
The K-1770-3-EWP K-1770 shares all of the features of the -3
in addition to Enhanced Weather Protection (EWP) for outdoor
installations where the unit is exposed to precipitation or
condensation. EWP products feature foam rubber gaskets
and boots, sealed connections, gel-filled butt connectors, as
well as urethane or thermal plastic potted circuit boards with
internally sealed, field-adjustable trim pots and DIP switches
for easy on-site programming. For more info, see . DOD 859
K-1770-3
“Brushed Stainless Steel”
(similar to brushed nickel)
K-1770-3-BN
“Oil Rubbed Bronze”
(satin dark brown powder paint
with fine copper metallic)
Features
Apartment entry phone when used with the Apartment Entry Dialer K-1900-3
or Apartment/Office Entry Controller or C-4000 C-3000 Apartment Entry
Controller
• Use with a to control 1 or 2 (expandable to 8) ( ) Viking C-500 DOD 177
K-1770’s and door/gate control on a single phone line
• Use with a to control 1 to 4 s and door/gate control Viking C-2000B K-177 0’
on a single phone line ( ) DOD 156
• Courtesy and customer assistance phone
Automated teller (ATM) phone
• Use with a for proximity card reader door control Viking ES-1
• Provide unique front and back door chimes and paging when use with a
Viking SLP-1 SLP-4 C-2000Bor and
• Kiosk phone with (100 number speed dialing) when used with the K-1900-9
Multi-Number Dialer ( ) DOD 321
• Use with Viking’s Proximity Cards: , , PRX-C PRX-C-ISO PRX-FOB (DOD 198)
Entry Phone Power: Telephone line powered 20V DC/20mA minimum
Proximity Card Reader Power: 5 to 14V DC @ 60mA maximum
Dimensions: Overall: 5.5” x 6.5” x 2.6” (140mm x 165mm x 66mm),
Rough-in box: 4.5” x 5.5” x 2.5” (114mm x 140mm x 64mm)
Shipping Weight: 3.5 lbs (1.6 kg)
Environmental: -30°F to 150°F (-34°C to 65°C)
Humidity - K-1770-3: 5% to 95% non-condensing
Humidity - K-1770-3-EWP: Up to 100% condensing
Speaker Volume: Approximately 70 db maximum @1m
CPC Disconnect Time: 500ms minimum
REN #: 0.5 A
Connections: Gel-filled tip and ring connectors
Applications
Specifications
• Built-in 125KHz 26-bit Wiegand proximity card reader with LED,
beep card read confirmation, and EWP board protection
• Compatible with the following Viking Proximity Cards and Fobs:
PRX-C PRX-C-ISO PRX-FOB (DOD 198), and
Vandal Resistant Features: 14 gauge louvered 316 stainless
steel faceplate with permanent laser etched graphics, stainless
steel “Call” button, heavy duty metal keypad and T-10 Torx
security mounting screws, scratch resistant powder coating
(K-1770-3-BN)
Marine grade 316 stainless steel Weather Resistant Features:
faceplate, screws and and push button switch. Switch internally
sealed per IP67. Mylar speaker. Self-draining mic mount.
Faceplate, mic and speaker gaskets. Weather Resisant powder
paint (K-1770-3-BN)
is designed to meet IP66 Ingress Protection K-1770 -3-EWP
Rating (see for more information) DOD 859
Available in 2 standard faceplate finishes: 316 brushed stainless
steel or oil rubbed bronze powder paint
• Blue “in use” LED
• Telephone line powered
• Volume adjustments for microphone and speaker
Advanced call progress detection: disconnects on busy signal,
return to dial tone, CPC, reorder tone, maximum call time out and
40 second silence time out
• Selectable auto-answer feature for monitoring
• Selectable push button disconnect
• Zinc plated steel rough-in box with (2) 3/4” conduit knockouts
• Optional Surface Mount Box available ( ) VE-6x7 DOD 424
Optional to illuminate the front panel at night (VE-LIGHT DOD 428)
DESIGNED, MANUFACTURED AND SUPPORTED IN THE USA
K-1770-3 Series
Entry Phones with Keypads
and Proximity Card Readers
September 29, 2023
PRODUCT
MANUAL
SECURITY & COMMUNICATION
VIKING
Optional Instruction Label (included):
Clean surface and adhere label when
using a K-1770-3 with a K-1900-3
Apartment Entry Dialer.
(4) 6-32 X 3/4”
Stainless steel,
flat head, T-10
Torx security
screws (included)
(1) .74”
diameter Rear View of
the Optional
VE-6x7 Surface
Mount Box
3.0” 3.3”
3.0”
2.25”
Condensation
Drain Hole
5.64”
6.72” 3.25”
(2) 0.2 x 0.43 slots
OR
Optional VE-6x7
Surface Mount Box
(not included)
The optional VE-6x7 Surface Mount Box (above) is designed
to be surface mounted to a single gang box, double gang box,
or VE-GNP Gooseneck Pedestal (shown right). For more
information on the VE-6x7 VE-GNPand , see DOD 424.
Peel paper liner and adhere gasket to back of
panel, centering over mounting holes. Caution:
For rough surfaces (ie: brick, stucco, etc.)
additional caulking may be required.
4.5”
2.5”
3/4” Conduit
Knockouts
5.5”
Rough-In
Box
(included)
(4) 0.38” diameter
K-1705-3-EWP
shown with VE-6x7
Surface Mount Box
and VE-GNP
Gooseneck
Pedestal
(not included)
Ca
ll
VIK IN G
©
12
AB
C
3
DE F
4
G
HI
5
JKL
6
MN O
7
PR
S
8
TUV
9
WXY
0
OPE R
#
P
ress "Ca
ll"b utt o
n
th en
en t er ten
an
t code
2
Features Overview
Push Button Switch: Push to
initiate call, push again to
disconnect. Solid 316 stainless
steel internally sealed per IP67.
Speaker Screen: Speaker screen
with 0.018" diameter holes to prevent
punctures from paperclips, etc.
Faceplate Material: 14 gauge 316
stainless steel. The SS model has
a #4 brushed finish, the BN models
have a powder painted finish.
Speaker: Mylar speaker with
rubber gasket to maintain
water-tight seal and eliminate water
deterioration.
Blue Call LED: Flashes during
dialing, then lights steady when
answered.
Microphone: Omni-directional
microphone with protective
water-resistant cloth.
Condensation Drain Hole
Mounting Screws: (4) 6-32 X 3/4”
Marine grade 316 stainless steel,
flat head, T-10 Torx security screws
and drive bit (included)
Laser Etched Graphics: For long
lasting easy to read graphics.
(copper metallic lettering on model
K-1770-BN-3)
Proximity Card Reader: 26-bit
Wiegand, 125KHz, red LED turns
off and transducer will beep during
card read. Fully potted EWP. Read
range 1.25" to 2.0". Impact resistant
polycarbonate lens with water-tight
gasket.
12
ABC
5
JKL
8
TUV
0
OPER
4
GHI
7
PRS
#
3
DEF
6
MNO
9
WXY
VIKING
VIKING
VIKING
VIKINGVIKING
©
Power: 5 to 14V DC @ 60mA maximum
Maximum Cable Length: 500 ft 24 Awg stranded shielded
(Belden 9537)
Frequency: 125KHz
Format: 26 bit Wiegand
Read Range: 1.25” to 2.0”
Technologies Supported: Viking , PRX-C PRX-C-ISO,
PRX-FOB, certain legacy HI proximity protocols* and
certain AWID 125Khz proximity protocols**
Transducer: Beeps during card read
LED: Red, turns off during card read
Humidity: Up to 100% (fully potted EWP)
Operating Temperature: -34° C to 65° C (-30° F to 150° F)
* HID and the HID logo are registered trademarks of HID
Global Corporation, an ASSA ABLOY company. All other
trademarks are the property of their respective owners.
** AWID is a trademark of Applied Wireless Identification Group.
Proximity Card Reader Specifications
Installation
A. Mounting
3
VIKING
Mode l:
XXXXXX
XXXXXX
Se rial No : XXXXX XXX
Viking Electronics , Inc. (715) 3 86- 88611531 Industrial St., Hudson, WI 54016
P/N: DEV: RoHS
5.5”
4.04”
6.5”
5.12”
OR
* C.O. Line or Analog
PABX/KSU Station
Spade
Terminal
(included)
*** Earth
Ground
(optional)
Red
(Ring)
Green
(Tip)
Rear View of
the K-1770-3
** Gel-Filled
Connectors
(included)
B. Wiring the K-1770-3 Phone
** Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge
wire with a maximum insulation of 0.082 inches. Cut off stripped wire ends prior to terminating.
*** Note: To increase surge protection, loosen the PCB
mounting screw labeled (shown right) and fasten a wire
with spade terminal (included) from the mounting screw to
Earth Ground (grounding rod, water pipe, etc.)
* Note: When installing a line powered phone on a low
voltage and/or low loop current phone system extension, a
TBB-1B Talk Battery Booster may be required ( .DOD 632)
Model DOD# Description
C-500 177 Advanced 2 Door Controller (see page 5)
C-2000B 156 Advanced 4 Door/Gate Controller (see page 6)
C-3000 162 Multi-Tenant Entry System (see page 7)
C-4000 164 Apartment/Office Entry Controller (page 7)
K-1900-3 312 Apartment Entry Dialer (see page 6)
To Optional Viking Entry Controllers (not included)
C. Wiring the K-1770-3 Proximity Card Reader
VIKING
Mod e l:
XXXXXX
XXXXXX
Ser ial No: XXXXXXXX
Viki ng Ele ctr oni cs, I nc. (715) 386-886 1
1531 In dus tr ial St ., Hud so n, WI 54016
P/N: DEV: R oHS
Back View of
the K-1770-3
White (Data 1)
Green (Date 0)
- Black (GND)
+ Red (5-14VD) * Up to 500 ft
3-Wire Gel-Filled Butt Connectors
included (3M Scotchlok UR2)
24 Awg Stranded
Shielded Cable
(Belden 9537)
White
Green
Black
Red
Black
Red
Green
White
To Viking model
ES-1 (shown)
or
C-4000 (page 7)
or equivalent 26-Bit
Wiegand Card
Reader Controller
Viking Model ES-1 (not included,
see DOD 193 for more information)
Touch Tone
Programming Phone
(not included)
RAD-1A Remote Access
Device (not included,
see DOD 410)
Remote Touch Tone
Programming Phone
(not included)
OR
VIKING
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND ALONE
DOOR CONTROLLER
ENTRY SYSTEM
POWER 12V DC
MODEL ES-1
1
POWER
PROGRAM
PHONE
LOG
BUS
2 3 4 5
GANG
PROG
6789
WI EGAND
DEVICE
10 11
DOOR
STRIKE
N.O.
2
1
L
H
COM
N.C.
BLK
RED
GRN
WHT
Doorstrike
Power Supply
12-24V AC or DC
Doorstrike
12V DC
Adapter
(included
with ES-1)
OR
Share power with
12-24V AC/DC door
strike with 200mA
available current or use
the included 12V DC
adapter.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from
both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect
against such surges.


Specyfikacje produktu

Marka: Viking
Kategoria: System kontroli dostępu
Model: K-1770-3-EWP

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Viking K-1770-3-EWP, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje System kontroli dostępu Viking

Viking

Viking K-1200 Instrukcja

9 Października 2024
Viking

Viking K-1275-IP-EWP Instrukcja

9 Października 2024
Viking

Viking K-1770-IP Instrukcja

9 Października 2024
Viking

Viking K-1270-EWP Instrukcja

9 Października 2024
Viking

Viking K-1770-3-EWP Instrukcja

9 Października 2024
Viking

Viking K-1200-IP Instrukcja

9 Października 2024
Viking

Viking K-1705-IP-EWP Instrukcja

9 Października 2024
Viking

Viking K-1770-3 Instrukcja

9 Października 2024
Viking

Viking K-1275-IP Instrukcja

9 Października 2024
Viking

Viking W-3005-EWP Instrukcja

9 Października 2024

Instrukcje System kontroli dostępu

Najnowsze instrukcje dla System kontroli dostępu

Panduit

Panduit ACF05 Instrukcja

9 Października 2024
Hikvision

Hikvision DS-TMG035 Instrukcja

4 Października 2024
Hikvision

Hikvision DS-TMT202-D Instrukcja

4 Października 2024
Hikvision

Hikvision DS-TMT201-D Instrukcja

4 Października 2024
ZKTeco

ZKTeco KR613-OSDP Instrukcja

4 Października 2024
ZKTeco

ZKTeco KR614-OSDP Instrukcja

4 Października 2024
Provision ISR

Provision ISR EC-001 Instrukcja

3 Października 2024
Indexa

Indexa EW01R Instrukcja

3 Października 2024