PRO 18.000 Inverter
Instruction Manual
VERY IMPORTANT!
Do not install or use your portable air conditioning unit before carefully reading this instruction
manual. Please retain this manual for product warranty and future reference
SPECIFICATIONS (approximations)
CAUTION!
!!
!
1. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
2." DO NOT BLOCK VENTILATION "! Please ensure the inlet and outlet ventilation is not
blocked.
3. Always operate this unit on a horizontal surface to avoid water leakage.
4. Do not operate this unit in a corrosive environment.
5. Operate this unit in an ambient temperature of 32°C or less when the unit is in the cooling
function. Therefore it might be necessary to start the unit early in the morning on warm days
to start with a cool room temperature below 32°C.
Contrarily, when the unit is in the heating function, the ambient temperature should be less
than 25°C.
6. Clean the air filter periodically to enjoy the most efficient cooling.
7. If you have turned the unit off, please wait at least 3 minutes before restarting. This
is to prevent any damage to the compressor.
8. This unit needs to be plugged into a more than 10 Amp power point. Please do not
use extension cords with this unit.
9. This unit is for indoor operation only.
10. Please ensure the adjustable air vent is open whilst in operation. The exhaust hose and
drain pipe must be extended to the closest window prior to use.
11. If the supply cord is damaged, it must be replaced by the manufacturer, service
agent or similarly qualified person.
12. The batteries from the remote control must be removed from the appliance before it
is scrapped and disposed of safely.
13. Please do not turn off the unit at the power point when the unit is running. Use the power
button to turn unit off before turning off at power point.
14. If the unit was turned off at the power point please wait at least 3 minutes before
restarting the unit.
Model No. PRO 18.000 Inverter
Power Source 230V~50Hz AC
Power Consumption(EN14511)
Rated Power(EN60335) 2200W
2300W
Cooling Capacity 5300W
Heating Capacity 5300W
Air Flow 600 M
3
/H
Dehumidification 70 L/DAY
Refrigerant R410A
Dimensions (mm) 476W x 358D x 840H
Net Weight 36KG
Important.
The air conditioning unit must always be stored and
transported upright.
In case of doubt we suggest to wait for at least 24
hours before you start the air-conditioning unit.
PORTABLE AIR CONDITIONER
Your Air Conditioner has been designed and manufactured to the highest standards of
modern engineering. This unit has been specifically designed to provide comfort in any room,
particularly in warmer conditions and larger rooms than suitable for standard air conditioners.
Features include:
- Easy glide castors – can be moved easily from room to room
- Simple DIY installation – no electrician required – just plug into a standard 10 amp power
point!
- Powerful dehumidification process and filtered air cycle for improved breathing conditions
- Remote control and soft touch control panel
- 24 hour programmable timer that can be used with either the air conditioning or
dehumidification setting
- Unique sleep control function
- Inverter technology for fast and efficient cooling
- Self evaporative system ensuring no drip tray or hose is required
- 220-240 Volt 50Hz operation
- 1.8 meter cord with plug
NAMES OF THE PARTS
1. Power
2. Display screen
3. Adjustable air vent
4. Window kit adaptor
5. Joint tube
6. Exhaust tube
7. Drain hose
8. Cool inlet
9. Cool air filter
10. Hot inlet
11. Drain plug
12. Hot air filter
Note: Please ensure drain plug is fitted before use.
PUSH BUTTON SWITCHES & DESCRIPTION OF FUNCTION
Specyfikacje produktu
Marka: | Suntec Wellness |
Kategoria: | kontrola klimatu |
Model: | PRO 18000 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Suntec Wellness PRO 18000, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje kontrola klimatu Suntec Wellness
25 Września 2024
23 Września 2024
20 Września 2024
19 Września 2024
18 Września 2024
17 Września 2024
17 Września 2024
10 Września 2024
7 Września 2024
6 Września 2024
Instrukcje kontrola klimatu
- kontrola klimatu AEG
- kontrola klimatu Sharp
- kontrola klimatu Nobo
- kontrola klimatu Domo
- kontrola klimatu Eberle
- kontrola klimatu Truma
- kontrola klimatu IFM
- kontrola klimatu Techno Line
- kontrola klimatu OneConcept
- kontrola klimatu Buderus
- kontrola klimatu Viessmann
- kontrola klimatu Perel
- kontrola klimatu Redmond
- kontrola klimatu Vaillant
- kontrola klimatu TriStar
- kontrola klimatu Inventum
- kontrola klimatu Solac
- kontrola klimatu Eheim
- kontrola klimatu Livington
- kontrola klimatu Tectro
- kontrola klimatu Rittal
- kontrola klimatu Alpina
- kontrola klimatu EXCELLENT Electrics
- kontrola klimatu EWT
- kontrola klimatu Stiebel Eltron
- kontrola klimatu Elco
- kontrola klimatu Trebs
- kontrola klimatu Magnum
- kontrola klimatu Technoline
- kontrola klimatu Duux
- kontrola klimatu Bulex
- kontrola klimatu Faber
- kontrola klimatu Turmix
- kontrola klimatu Eufab
- kontrola klimatu Simplify
- kontrola klimatu Econo-Heat
- kontrola klimatu Finicompressors
- kontrola klimatu Sawo
- kontrola klimatu Webasto
- kontrola klimatu Mr Safe
Najnowsze instrukcje dla kontrola klimatu
14 Stycznia 2025
7 Stycznia 2025
27 Grudnia 2024
27 Grudnia 2024
27 Grudnia 2024
14 Grudnia 2024
14 Grudnia 2024
5 Grudnia 2024
9 Października 2024
3 Października 2024