Instrukcja obsługi Suntec Wellness DryFix
Suntec Wellness
kontrola klimatu
DryFix
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Suntec Wellness DryFix (3 stron) w kategorii kontrola klimatu. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/3
SAFETY INFORMATION
1. Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe
place.
2. Never immerse the appliance in water or other liquids.
3. Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance
was dropped or otherwise damaged.
4. Electric appliance may only be repaired by qualified personal, improper repair work can be a source of considerable
danger for the users.
5. Children are not aware of the hazards of electric appliance. Therefore, never allow children to manipulate electric
appliance unless properly supervised.
6. Disconnect the appliance from mains power whenever it is not in use, before relocating it, and before cleaning,
7. Operate the appliance only at the voltage specified on the type plate.
8. Use the appliance only in the household, and only for the purpose it was designed for.
9. Do not place heavy objects on the appliance.
10. To prevent spillage, empty the water tank before relocating the appliance.
11. Do not tip the appliance to any side as escaping water could damage the appliance.
12. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
13. When the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
14. The devices should be installed at minimum distant of 50CM from the wall or other obstacle.
15. Unplug the appliance before cleaning.
OPERATION INSTRUCTIONS
1. Control panel
2. Air outlet
3. Handle
4. Front panel
5. Back panel
6. Water out hole
7. Water tank
CONTROL PLATE DESCRIPTION
OPERATION INSTRUCTIONS
Starting the unit
1. Firstly, turn the humidity control switch to the “OFF” position.
2. Plug in the dehumidifier.
3. Turn on the humidity control switch (to right side) and turn the same switch to the reading of the desired humidity (60% in
general as shown on position ”4”).
CONTROL SWITCH
POSITION NO. APPROXIMATE
HUMIDITY SETTING
8 20﹪
7 30﹪
6 40﹪
4 60﹪
2 80﹪
Turning off the unit
1. Turn the humidity control switch to the left side to the “OFF” position and the power supply is cut off and the unit stops in
operation.
2. If the dehumidifier is not in use for a long time, please disconnect the power cord plug from the outlet.
PRECAUTIONS
1. The dehumidifier shall not operate if the humidity setting is higher than the ambient humidity.
2. Drain the water in the water storage tank when the water in the tank is full and the water level indicator light illuminates.
And then install the empty water tank back to its position, so the unit can continue its operation.
3. When the unit stops, you have to wait for 3 minutes before you can restart the unit to protect the compressor from damage.
4. The humidify and its related position number on the humidity control switch:
5. The operational temperature range for this unit is 5-35 C°.
6. If the dehumidifier does not start (the operational light does not illuminate) or the dehumidifier makes intermediate stop on
unknown reasons, please check the plug and power supply for poor connection. If the plug and power supply are in normal
condition, wait for 10 minutes and restart the unit (because take about 10 minutes to reposition). If the unit still does not
start in 10 minutes, please contact your local distributor service station for repair.
7. When the dehumidifier is in operation, the running compressor will produce heat and make the room temperature higher.
This is normal condition.
DRAINAGE INSTRUCTION
The extracted water can be collected by water tank, or drained continuously
with a PVC hose (not available):
USE OF WATER TANK
When the water drain mouth is blocked by the plug, the water will automatically run to the water tank.
When the water full indicator illuminates, the tank is full, and the compressor and the fan will stop operation, please empty the
water tank:
1. Remove the water tank as Fig 01. and empty it.
2. Insert gently the water tank into the unit reach to its original position.
CONTINOUS DRAINAGE
1. When you want to use this function, please pull out the water tank, and plug the discharge water pipe in “Water out
hole” (See Fig.02). replace the water tank into the unit, then you can operate the unit.
Fig 02
FILTER REMOVAL
•The filter can be removed from its slot by gripping the filter handle and sliding it out from the back of the appliance.
• Every 2 weeks, remove the filter and clean it with warm water, below 40°C. Allow it to dry naturally and then replace.
Fig 01
MAINTENANCE INSTRUCTION
1. The unit is not allowed to be located on the floor of soft and uneven surface when the unit is in operation to avoid
occurrence of vibration and noise.
2. Never insert any slim rod and hard object into the unit body to avoid occurrence of hazard or unit failure.
3. During power off or when not in use for a long time, please pull out the power cord from the outlet.
4. For a better dehumidifying effect, the areas in front and rear of the unit should be clear and free from obstacles, which will
block the air flow for the unit.
5. Clean the filtering net once every two weeks (never use alcohol, gasoline, on or hot water with a temperature of 40°C.
SPECIFICATIONS
MODEL
SPECIFICATION
Dry Fix 1000 Dry Fix 1200 Dry Fix 1600
Dry Fix 2000
POWER SUPPLY 230V~50Hz
POWER INPUT 250W 260W 410W 480W
RUNNING CURRENT 1.2A 1.2A 2.0A 2.5A
NET WEIGHT 11,1 Kg 11,2 Kg 13,3 Kg 13,7 Kg
MOISTURE REMOVAL
liter/day 30 RH 80%℃) 10 liter/day 12 liter/day 16 liter/day 20 liter/day
CABINETDIMEMSION (W)365x(D)220 x(H)490
TEMP. RAHGE FOR USE 5°C~32°C
WATER TANK CAPACITY 2.3L
NOTE CONCERNING PROTECTION OF ENVIRONMENT
© 2012 KLIMATRONIC
®
DRY FIX
SUNTEC WELLNESS GMBH / HOLZSTRASSE 2 / 40 221 DÜSSELDORF / DEUTSCHLAND
Fig 03
This marking indicates that this product should not be disposed with other household wastes throughout the
EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle
it responsibly to promote the sustainable reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.
Specyfikacje produktu
Marka: | Suntec Wellness |
Kategoria: | kontrola klimatu |
Model: | DryFix |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Suntec Wellness DryFix, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje kontrola klimatu Suntec Wellness
25 Września 2024
23 Września 2024
20 Września 2024
19 Września 2024
18 Września 2024
17 Września 2024
17 Września 2024
10 Września 2024
6 Września 2024
3 Września 2024
Instrukcje kontrola klimatu
- kontrola klimatu AEG
- kontrola klimatu Sharp
- kontrola klimatu Nobo
- kontrola klimatu Domo
- kontrola klimatu Truma
- kontrola klimatu OneConcept
- kontrola klimatu Buderus
- kontrola klimatu Redmond
- kontrola klimatu Vaillant
- kontrola klimatu TriStar
- kontrola klimatu Solac
- kontrola klimatu Livington
- kontrola klimatu Rittal
- kontrola klimatu Alpina
- kontrola klimatu EXCELLENT Electrics
- kontrola klimatu Stiebel Eltron
- kontrola klimatu Elco
- kontrola klimatu Trebs
- kontrola klimatu Magnum
- kontrola klimatu Technoline
- kontrola klimatu Duux
- kontrola klimatu Bulex
- kontrola klimatu Faber
- kontrola klimatu Turmix
- kontrola klimatu Eufab
- kontrola klimatu Simplify
- kontrola klimatu Econo-Heat
- kontrola klimatu Finicompressors
- kontrola klimatu Sawo
- kontrola klimatu Webasto
- kontrola klimatu Mr Safe
Najnowsze instrukcje dla kontrola klimatu
9 Października 2024
3 Października 2024
2 Października 2024
29 Września 2024
29 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024
28 Września 2024