Instrukcja obsługi Ruckus Wireless ZoneFlex T610
Ruckus Wireless
Punkt dostępu
ZoneFlex T610
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Ruckus Wireless ZoneFlex T610 (4 stron) w kategorii Punkt dostępu. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/4
Copyright © 2016 Ruckus Wireless, Inc.
Published June 2016, Part Number 800-71230-001 Rev A
Page 1 of 4
T610 Access Point
Quick Setup Guide
This Quick Setup Guide provides step-by-step instructions on how to
field-install the Ruckus Wireless T610 access point (AP).
For detailed information on planning the installation, performing a site
survey, and operating the T610, refer to the ZoneFlex Outdoor Access
Point User Guide, available at https://support.ruckuswireless.com.
WARNING: Only trained and qualified personnel should be allowed to
install, replace, or service this equipment.
WARNING: Installation of this equipment must comply with local and
national electrical codes.
CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip
loop in any cable that is attached to the AP or the building. This will
prevent water from running along the cable and entering the AP or the
building where the cable terminates.
CAUTION: Be sure that grounding is available and that it meets local
and national electrical codes. For additional lightning protection, use
lightning rods and lightning arrestors.
CAUTION: Make sure that proper lightning surge protection
precautions are taken according to local electrical code.
WARNING: Ruckus Wireless strongly recommends that you wear eye
protection before mounting the T610.
T HIS GUIDE IN O LTHER ANGUAGES
请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com.
Vous trouverez la version française de ce guide à l'adresse suivante
https://support.ruckuswireless.com.
こ の ガ イ ド の⽇本語版は https://support.ruckuswireless.com
で ご 覧 く だ さ い 。
이 가이드의 버전은 웹 사이트 한국어
( ) .https://support.ruckuswireless.com 에서 확인하시기 바랍니다
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en
https://support.ruckuswireless.com.
BEFORE YOU BEGIN
Before deploying your Ruckus Wireless T610, verify that all items listed
in Package Contents are included in the package. If any item is
damaged or missing, notify your authorized Ruckus Wireless sales
representative. Also, make sure that you have the required hardware
and tools.
REQUIRED HARDWARE AND TOOLS
• Customer-supplied outdoor-rated three-wire (1-2mm2 or 14-
18AWG) AC cable
• 1/2” (13mm) flat-blade screwdriver or equivalent
• No. 2 Phillips screwdriver
• Small flat-blade screwdriver
• Torque wrench or torque screwdriver with sockets
• Long-nose pliers
• Electrical wire stripping and terminal crimping pliers
• Pipe or pole --OR-- a sturdy flat surface
• Electric drill with drill bits and customer-supplied wall anchors, flat
washers, and hex nuts for flat-surface mount
• Four factory-supplied 1/2” (12.7mm) wide stainless steel
adjustable clamps, 2.5” (63.5mm) diameter, for main mounting
bracket on smaller poles
• Ruler
PACKAGE CONTENTS
A complete T610 field installation package includes all of the items
listed below (see Figure 1for illustrations):
• T610 Access Point (A)
• Two M25 data cable glands (B)
• Ground wire with lug (C)
• Service Level Agreement/Limited Warranty Statement
• Declaration of Conformity
• Regulatory Statement
• Ruckus Wireless AP Getting Started Guide
• This Quick Setup Guide
Figure 1: Package Contents
NOTE: The outdoor AP Mounting Bracket and security cable are
optional accessories that must be purchased separately.
CAUTION! The minimum software revision for the T610
is ZoneDirector (ZD) 9.13.1 or later, or SmartZone (SZ) 3.4
or later, or standalone AP firmware 104.0 or later.
DO NOT CONNECT THE T610 TO A RUCKUS
WIRELESS ZONEDIRECTOR RUNNING 9.13 OR
EARLIER.
Copyright © 2016 Ruckus Wireless, Inc.
Published June 2016, Part Number 800-71230-001 Rev A
Page 2 of 4
S TEP 1: CONNECTING AND SEALING THE RJ-45
CABLES
Connect and seal the RJ-45 cable(s) using the M25 data cable gland
as shown in Figure 3.
WARNING: Do not use any PoE injector not tested and approved by
Ruckus Wireless to power the T610 Access Point.
WARNING: Do NOT plug PoE in power into the non-PoE Port (see
Figure 2).
Figure 2: T610 bottom view
1Feed the end of the cable through the sealing nut, rubber O-ring,
clamping ring assembly and cable gland base as shown in Figure
3.
Figure 3: RJ-45 cable and cable gland assembly
2Use a wide flat-blade screwdriver to remove the required (PoE IN)
blanking cap from the T610.
3Connect the cable to the Ethernet port on the T610.
4Tighten the cable gland base into the T610 chassis to 7 N.m or
62 in-lbs.
5Wrap the clamping ring assembly around the rubber O-ring. Make
sure that the clamping ring assembly fully encloses the rubber O-
ring.
6Seat the clamping ring assembly and rubber O-ring in the cable
gland base.
7Hand-tighten the sealing nut.
S TEP 2: ATTACHING THE U-JOINT BRACKET TO THE
MOUNTING BRACKET
NOTE: The following mounting instructions require purchase of
optional accessories that are not included in the standard T610
package. The outdoor AP Mounting Bracket and safety cable are
optional accessories that must be purchased separately.
1Position the U-joint bracket on the mounting bracket.
Figure 4: U-joint bracket attached horizontally to the mounting bracket
NOTE: Mount the U-joint bracket in any direction on the mounting
bracket, preferably to allow AP azimuth adjustments. Then the AP
bracket allows AP elevation adjustments.
2Use four 1/4-28 bolt and washer sets (A) to mount the U-joint
bracket (B) to the mounting bracket (C). Tighten the bolts to 9.5
N.m (7 ft-lbs).
3Continue with Step 3a: Attaching the Mounting Bracket to a
Flat Surface or Step 3b: Attaching the Mounting Bracket to a
Metal Pole.
S TEP 3A: ATTACHING THE MOUNTING BRACKET TO A
FLAT SURFACE
1Place the mounting bracket at the location on the flat surface
where you want to mount the AP. Use the holes on the mounting
bracket as a template to mark the locations of the mounting
holes.
Figure 5: Mounting bracket flat surface holes
2Remove the mounting bracket from the flat surface.
3Drill holes required for the mounting hardware.
NOTE: The hardware required for mounting to a wall are not included
in the mounting kit.
4Attach the mounting bracket to the flat surface using the
mounting hardware.
5Using the mounting hardware instructions, tighten the hardware to
secure the mounting bracket.
6Continue with Step 4: Mounting the Linkage Bracket to the U-
Joint Bracket.
S TEP 3B: ATTACHING THE MOUNTING BRACKET TO A
METAL POLE
1Insert the open end of one steel clamp into the upper two slots on
the mounting bracket.
2Take the other steel clamp and insert it into the lower two slots on
the mounting bracket.
NOTE: The clamps can be daisy-chained together to accommodate
larger poles.
3Use the clamps to attach the mounting bracket to the pole.
Tighten the clamps to 3 N.m or 27 in-lbs, or per manufacturer’s
specifications.
Figure 6: Attaching the mounting bracket to a vertical pole
4Continue with Step 4: Mounting the Linkage Bracket to the U-
Joint Bracket.
S TEP 4: MOUNTING THE L BINKAGE RACKET TO THE
U-JOINT BRACKET
The linkage bracket attaches to the U-joint bracket using an M8 bolt
and washer set. The linkage bracket is symmetrical, and either end
can be attached to the U-joint bracket.
NOTE: Make sure that linkage bracket is installed with its serrated
external-tooth lock washer on the inside of the U-joint bracket
flanges. This ensures that the azimuth adjustment does not
change.
1Loosely assemble the linkage bracket (A), the U-joint bracket (C),
one serrated external-tooth lock washer (B), and one M8 bolt
and washer set (D).
Cable gland base
Clamping ring assembly
Rubber O-ring
Sealing nut
C
B
A
Copyright © 2016 Ruckus Wireless, Inc.
Published June 2016, Part Number 800-71230-001 Rev A
Page 3 of 4
Figure 7: Attaching the linkage bracket to the U-joint bracket
2Set the azimuth required by the AP.
3Tighten the M8 bolt to 13.6 N-m (10 ft-lbs).
4Continue with Step 5: Attach the AP bracket to the linkage
bracket.
S TEP 5: ATTACH THE AP BRACKET TO THE LINKAGE
BRACKET
Attach the AP bracket to the linkage bracket using the included bolt,
nut, lock washer, flat washer, serrated external-tooth washer shown in
Figure 8.
The AP bracket attaches to the linkage bracket using an M8 bolt and
washer set. The linkage bracket is symmetrical, and either end can be
attached to the AP bracket.
NOTE: Make sure that linkage bracket is installed with its serrated
external-tooth lock washer on the inside of the AP bracket flanges.
This ensures that the elevation adjustment does not change.
1As described in Step 4: Mounting the Linkage Bracket to the
U-Joint Bracket, loosely assemble the AP bracket (shown in
Figure 9), the linkage bracket (A in Figure 7), the second
serrated external-tooth lock washer (B in Figure 7), and the
second M8 bolt and washer set (D in Figure 7).
Figure 8: Attach the linkage bracket to the AP bracket
S TEP 6: ATTACHING THE AP BRACKET TO THE
ACCESS POINT
1Place the AP bracket onto the back side of the AP so that the four
larger screw holes on the bracket align with the four screw holes
on the AP. Make sure that the end of the AP bracket with the
hoisting loop is on the same side as the AP PoE IN port.
Figure 9: Attaching the AP bracket to the AP
2Use four 0.5-inch x 0.250-28 hex bolts with split lock and flat
washer sets to mount the AP bracket to the AP. Tighten the bolts
to 2.5-3.0 N.m or 22-27 in-lbs.
CAUTION: Make sure that the screws are no longer than 0.5 inch.
If a screw is longer than 0.5 inch, it can damage the AP chassis.
3If required, suspend the AP by attaching a carabiner to the
hoisting loop on the AP bracket.
NOTE: This kit may include extra screws, nuts and washers. You
may use the extras wherever required.
4Continue with Step 7: Set the Elevation and Tighten Elevation
Bolt.
S -TEP 7: SET THE ELEVATION AND T EIGHTEN LEVA
TION BOLT
1Set the elevation required by the AP.
2Tighten the M8 bolt to 13.6 N-m (10 ft-lbs).
S TEP 8: EARTH GROUNDING THE AP
CAUTION: Make sure that earth grounding is available and that it
meets local and national electrical codes. For additional lightning
protection, use lightning rods and lightning arrestors.
NOTE: The color coding of ground wires varies by region. Before
completing this step, check your local wiring standards for
guidance.
• Using the factory-supplied ground wire and ground screw/
washer set, connect a good earth ground to the AP chassis
ground point (Figure 10).
CAUTION: The T610 AP includes one 12mm stainless steel M6x1
earth ground screw with split lock and flat washers. Make sure
that any replacement screw is no longer than 12mm. If a screw is
longer than 12mm, it can damage the AP chassis.
Figure 10: Connect good earth ground to AP here
S TEP 9: INSTALLING THE S CECURITY ABLE
NOTE: The security cable is an optional accessory that must be
purchased separately.
1Thread the security cable through the mounting bracket (A) and
through the eye on the cable itself (B), as shown in Figure 11.
2Attach the safety cable to the AP (C) in Figure 11.
Figure 11: Attaching the security cable
Congratulations! You have mounted your T610 access point.
A
C
B
D
Specyfikacje produktu
Marka: | Ruckus Wireless |
Kategoria: | Punkt dostępu |
Model: | ZoneFlex T610 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Ruckus Wireless ZoneFlex T610, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Punkt dostępu Ruckus Wireless
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
30 Września 2024
Instrukcje Punkt dostępu
- Punkt dostępu Tenda
- Punkt dostępu TP-Link
- Punkt dostępu Bosch
- Punkt dostępu StarTech.com
- Punkt dostępu TRENDnet
- Punkt dostępu D-Link
- Punkt dostępu HP
- Punkt dostępu Mikrotik
- Punkt dostępu Cisco
- Punkt dostępu Moxa
- Punkt dostępu Lindy
- Punkt dostępu ZyXEL
- Punkt dostępu V7
- Punkt dostępu Dell
- Punkt dostępu Linksys
- Punkt dostępu Dahua Technology
- Punkt dostępu Renkforce
- Punkt dostępu Netgear
- Punkt dostępu AVM
- Punkt dostępu Homematic IP
- Punkt dostępu Totolink
- Punkt dostępu Black Box
- Punkt dostępu Lancom
- Punkt dostępu Intellinet
- Punkt dostępu Devolo
- Punkt dostępu Kingston
- Punkt dostępu Speco Technologies
- Punkt dostępu Mercusys
- Punkt dostępu Draytek
- Punkt dostępu Edimax
- Punkt dostępu AirLive
- Punkt dostępu EnGenius
- Punkt dostępu Planet
- Punkt dostępu LevelOne
- Punkt dostępu Ubiquiti Networks
- Punkt dostępu Juniper
- Punkt dostępu Cudy
- Punkt dostępu Netis
- Punkt dostępu Allnet
- Punkt dostępu Media-Tech
- Punkt dostępu Grandstream
- Punkt dostępu Allied Telesis
- Punkt dostępu Sitecom
- Punkt dostępu Fortinet
- Punkt dostępu Techly
- Punkt dostępu Steren
- Punkt dostępu Buffalo
- Punkt dostępu Macally
- Punkt dostępu Aruba
- Punkt dostępu Hawking Technologies
- Punkt dostępu INCA
- Punkt dostępu Moog
- Punkt dostępu Advantech
- Punkt dostępu Hercules
- Punkt dostępu SMC
- Punkt dostępu CradlePoint
- Punkt dostępu Silex
- Punkt dostępu Aerohive
- Punkt dostępu WatchGuard
- Punkt dostępu NUVO
- Punkt dostępu IP-COM
- Punkt dostępu Syscom
- Punkt dostępu Meru
- Punkt dostępu Amped Wireless
- Punkt dostępu Cambium Networks
- Punkt dostępu 3Com
- Punkt dostępu Bintec-elmeg
- Punkt dostępu Mach Power
- Punkt dostępu Brocade
- Punkt dostępu Insteon
- Punkt dostępu Comtrend
- Punkt dostępu Premiertek
- Punkt dostępu Extreme Networks
- Punkt dostępu Atlantis Land
- Punkt dostępu Mojo
- Punkt dostępu FlyingVoice
- Punkt dostępu Luxul
Najnowsze instrukcje dla Punkt dostępu
14 Października 2024
13 Października 2024
12 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024