Instrukcja obsługi Pulsar PSC12015


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Pulsar PSC12015 (2 stron) w kategorii Nie skategoryzowane. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
1
PSC12015
PSC 12V/1,5A/62MM power supply
Edition: 7 from 22.01.2018
Supers edition: 6 from . .2017 edes 16 08
EN
Features of the power supply:
power output 1,5A/12VDC*
universal AC input voltage range 90÷264V
high eciency 81%
standby power <0,3W
eciency level: V
IP 67 case
protections:
SCP short-circuit protection
overvoltage protection (AC input)
overload (OLP)
warranty 2 year from the production date
1. Technical description.
1.1. General description.
Stabilized DC power supply is intended for supply CCTV cameras that require stabilised voltage of 12V DC.
The unit is protected against short-circuit and overload.
1.2.Technical parameters.
Supply voltage
90 ÷ 264V AC 50÷60Hz
Current consumption
0,16A@230V AC max.
Supply power
18W max.
Eciency
81%
Output voltage
12V DC
Output current tAMB<30°C
1 A instantaneous current - refer to graph 1. ,5
Output current tAMB=40°C
1A - refer to graph 1.
Ripple voltage
100mV p-p max.
Short-circuit protection SCP
electronic, automatic recovery
Overload protection OLP
105-150% of power supply, automatic recovery
IP protection class
IP67
Operation conditions
temperature 0 oC÷40 oC
relative humidity 20%...90%
Dimensions (LxWxH)
58 x 58 x 28 [mm]
Net/gross weight
0,16 19kg / 0, kg
Protection class PN-EN 60950-1:2007
II (second)
Lenght of DC cable
0,5m + plug DC5,5/2,1 female
Lenght of cable AC
0,3 m
Storage temperature
- 20ºC...+60ºC
* In order to extend the life of the power supply, the load current of 1A is recommended.
Graph 1.
Relation between output current and ambient
temperature (instantaneous load).
F .1. Dimensions of power supply.ig
* Refer to graph 1
2
1.3. Accessories.
For the power supplies are available accessories - fuse blocks and cable adapter. For details visit . www.pulsar.pl
2. Installation.
2.1. Requirements.
The power supply shall be mounted by the qualied installer having appropriate (required and necessary for a given country)
permissions and qualications for connecting (operating) low-voltage installations. The power supply shall be mounted in closed rooms,
according to the environment class II, of the normal air humidity (RH=90% max.) and the temperature within the range from 0°C to
+40°C.
In order to fulll LVD and EMC requirements the rules for power supplies, encasing and shielding shall be observed according
to application.
2.2. Installation procedure.
1. Fit the power supply inside the box or other device.
2. Connect the DC output to the load or to the terminal block.
3. Connect the power supply to the AC line.
4. After tests and operation control are performed, close installation box, case etc. and switch on
the power (230V AC).
3. Maintenance.
Any and all maintenance operations may be performed following the disconnection of the power supply from the power
network. The power supply does not require any specic maintenance procedures, however, in the case of signicant level of dust, it
should be cleaned with the compressed air.
WEEE MARK
According to the EU WEE Directive It is required not to dispose of electric or electronic waste
as unsorted municipal waste and to collect such WEEE separately.
Pulsar
Siedlec 150, 32- Poland 744 Łapczyca,
Tel. (+48) 14-610- -40, Fax. (+48) 14-610- - 19 19 50
e-mail:
biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl