Instrukcja obsługi Optex SIP-5030-IP-BOX

Optex Niesklasyfikowane SIP-5030-IP-BOX

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Optex SIP-5030-IP-BOX (22 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 4 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/22
- 1 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
2.3-4.0 m
(7.6-13 ft.)
INSTALLATION AND MAINTENANCE NOTES
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
No.59-1545-1 0905-01
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Detection of ambient temperature and illuminance for automatic
sensitivity management
- Advanced detection algorithm
- Double Dual/One Quad pryo-elements with patented Double
Conductive Shielding for main area
* Built-in creep zone detector (Double dual pyro-elements)
* Anti-vandalism functions
- Anti-rotation function with 3-axis accelerometer
- Anti-masking function with photo-beam
- Reinforced polycarbonate housing
- Max. 4 m (13 ft.) installation height
* Independent sensitivity selector for creep/near/far areas
* Independent N.C. and N.O. output for main area SIP-5030
* 2 x N.C. and N.O. independent output for main areas (Near and
Far areas ) SIP-100
* Adjustable alarm interval time
REDWALL-V
: Synthesized Intelligent PIR with creep zone
SIP-5030
SIP-100
Mount the detector so that the majority of trafc ow is across the detection pattern.
*1: Not used for the SIP-100.
2-1
INSTALLATION HINTS
Base
Fixing screw
for the base Main unit
Masking plate for
near area (*1)
Fixing rubber
form (*1)
Window
Fixing screw
for the cover
Cover
Far area mirror
Adjustment screws
(two facing each other)
Angle adjustment guide
Near area mirror
Arrow marking
Fixing screw
Nylon wire
loop
When servicing, the sensor
can be hooked onto the
base using the nylon wire
loop.
Creep unit
Synthesized Intelligent PIR
REDWALL-V series
- 2 -
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 60 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
*2: FAR AREA ALARM OUTPUT, when the NUMBER OF OUTPUTS select switch is
ON(3) (see Step 5-3).
*3: Both FAR AREA and NEAR AREA ALARM OUTPUT, when the NUMBER OF
OUTPUTS select switch is OFF(2).
And Only NEAR AREA ALARM OUTPUT, when the NUMBER OF OUTPUTS
select switch is ON(3) (see Step 5-3).
Name Function
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal. When
an object is placed close to the lens surface, for a
period of more than 20 seconds (approx.), the IR
anti-masking circuit will activate and generate a
trouble signal.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
When the system power switch is turned on while
the cover is closed, the mounting position of the
main unit itself will be determined and stored in
memory after approximately 10 seconds. Then,
if the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected. However, if you remove the
cover while keeping the system power turned on,
and if you close the cover again after correcting
the position of the main unit, the new position
of the main unit will be stored in memory after
approximately 10 seconds.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole
Open wiring cap
Main unit connector
Wall mounting hole
Wiring terminals
(SIP-100 ONLY)
Wall mounting hole
Bushing of wiring
hole
Wiring terminals
1 Loosen the
xing screw
for the
base.
2 Open.
3 Unplug
the cable
connector.
4 Pull out.
POWER INPUT
TAMPER OUTPUT *1
FAR AREA AND NEAR AREA *3
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE
OUTPUT
SPARE
4 Tighten and
secure the
xing screw
for the base.
2 Connect the
connector.
3 Close.
1 Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
CREEP
ALARM OUTPUT
(N.C.)
ALARM OUTPUT
(N.O.)
FAR AREA *2
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
(SIP-100 only)
- 3 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
DETECTION AREA SETTING
You can adjust the detection area by 90 degrees in a horizontal
direction and by 10 degrees in a vertical direction.
Correct the vertical detection angle according to the mounting
height of the sensor unit.
Applicable
models
SIP-5030 SIP-100
10°
10°
85° 85°
Cautions>>
To rotate the main unit counterclockwise, loosen the
RHside adjustment screw. To rotate the main unit
clockwise, loosen the LH-side adjustment screw.
Otherwise, you may find it difficult to tighten or you may
find that you cannot tighten the adjustment screw when
you are securing the main unit.
To rotate the unit counterclockwise
To rotate the unit clockwise
4-1
Main Detection Area Setting
Adjust the angle of the main unit in a horizontal direction so
that you can cover the desired detection area.
4
Power wires should not exceed the following lengths.
WIRE SIZE SIP-5030 SIP-100
12V DC 14V DC 24V AC 12V DC 14V DC 24V AC
0.33 mm2
(AWG22)
480
(1570)
640
(2100)
1370
(4490)
410
(1350)
550
(1800)
1280
(4200)
0.52 mm2
(AWG20)
760
(2490)
1010
(3310)
2160
(7090)
650
(2130)
860
(2820)
2020
(6630)
0.83 mm2
(AWG18)
1210
(3970)
1610
(5280)
3450
(11320)
1030
(3380)
1380
(4530)
3220
(10560)
m (ft.)
Adjust the angle of the main unit in a vertical direction so
that you can cover the desired detection area.
Cautions>>
If the mounting wall is at an angle, the arrow of the
main unit may exceed the top or bottom limit of “Angle
adjustment guide”. Always check this using the area
viewfinder or the walk tester. If the detection area is too
high or too low, an object outside the detection area may
be detected or incorrect object detection may occur.
Remove the cover.
Cautions>>
The cover is linked to the main unit by nylon wire loop so
that the cover does not fall. Do not pull the cover using
excessive force.
Mount the area viewfinder.
F2 F3 F4 F5
E2 E3 E4 E5
D1 D2
D3D 4
D5 D6
C1 C2 C3 C4 C5 C6
B1
B2 B3B4
B5
78910
123456
F1 F6
E1 E6
B6
50 30 (521 20 6)
(2)
(3)
(4)
(1)
Hooks
3 Slide the cover downward
and release the hooks.
1 Loosen two xing screws for
the cover and pull out the
cover until it stops.
Cover
2 Hold the heads of both cover xing screws
with your hands, and pull down and remove
the bottom section of the cover from the
main unit.
Adjustment
screw
3 Rotate the main unit.
2 Loosen the adjustment screw.
4 Tighten the adjustment screw slightly.
1 Loosen the xing
screw for the base.
Area plate
(an accessory)
Determine the
detection direction
(see Step 5- ).1
Put the red string
round the main unit.
Insert and
mount to
the main
unit.
Red string to
hold the main unit
Center circle
of the lens
Area viewnder AVF-1 (optional)
Inspection window
Insert the area
plate into the slot.
* Peel off the
protection
seal from
both faces
of the area
plate.
1
2
3
4
When mounted at a height of
2.3 meters (7.6ft.)
When mounted at a height of
4.0 meters (13ft.)
Align the arrow of the main
unit with the “Angle adjustment
g u i d e o f t he ad j u s t m e n t
screw. The main unit is usually
adjusted within the width of this
guide.


Specyfikacje produktu

Marka: Optex
Kategoria: Niesklasyfikowane
Model: SIP-5030-IP-BOX

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Optex SIP-5030-IP-BOX, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Optex

Optex

Optex WXI-R Instrukcja

6 Grudnia 2024
Optex

Optex VXS-AM Instrukcja

6 Grudnia 2024
Optex

Optex FTN-AM Instrukcja

6 Grudnia 2024
Optex

Optex AP2-20N Instrukcja

9 Października 2024
Optex

Optex CW-G2 Instrukcja

7 Października 2024
Optex

Optex WXS-RDAM Instrukcja

5 Października 2024
Optex

Optex OAM-DUAL T Instrukcja

5 Października 2024
Optex

Optex OM-105C Instrukcja

5 Października 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane