Filter
Cartridge
O-Ring
Filter Base
O-Ring MO U N TA I N SA F E T Y E S E A RC H R
INSTRUCTION
MANUAL
GUARDIAN™ PURIFIER
MO U N TA I N SA F E T Y E S E A R C H R
Fo r product info rmati on and ser vice co ntact
C a s c a d e Desi g ns, I nc.
40 00 F ir s t A v e n u e S o u t h , S ea t t le , WA 9 8 1 34 U S A
1 - 8 00 - 5 31 - 9 53 1 o r 2 06 - 5 05 - 9 5 0 0
w w w. m s r g e a r. c o m
i n f o@ c a s ca d e d es ig n s . c o m
Cascade Designs, Inc.
4000 First Avenue South, Seattle, WA 98134 USA
1-800-531-9531 or 206-505-9500
Cascade Designs, Ltd.
Dwyer Road, Midleton, County Cork, Ireland
(+353) 21-4621400
www.msrgear.com
Printed on recycled paper containing 30% post-consumer waste. 33-787_EN
TROUBLESHOOTING
SPECIFICATIONS
RECYCLED | RECYCLABLE
IMPORTANT
Read and understand this entire manual carefully before assembling or using this
water purifier. Keep this manual for future reference. If you do not understand this
manual or have any questions, please call Cascade Designs at
1-800-531-9531.
WARNING
BIOLOGICAL HAZARD
There are hazards associated with backcountry or international travel and
the use of water purifiers. Drinking untreated water can result in exposure to
harmful microorganisms and an increased risk of gastrointestinal illness.
Using this purifier improperly increases your risk of exposure to harmful
microorganisms and increases your risk of gastrointestinal illness. Reduce your
chances of becoming sick by following the warnings and instructions in this
manual and educating yourself on backcountry and international water safety.
YOU ARE RESPONSIBLE FOR YOUR OWN SAFETY AND THE SAFETY
OF THOSE IN YOUR GROUP. PLEASE USE GOOD JUDGMENT.
Never use the Guardian purifier to filter seawater or chemically contaminated
water, such as water from mining tailing ponds or near agricultural operations.
The Guardian purifier does not make potable water from these sources
and does not remove chemicals and radioactive materials,
or particles smaller than 0.02 microns.
Keep the Inlet Hose and other potentially contaminated parts away
from purified water to prevent cross contamination.
READ, UNDERSTAND, AND FOLLOW ALL instructions and warnings
in this manual before using this purifier. Failure to follow warnings and
instructions may result in gastrointestinal illness.
LIMITED WARRANTY/LIMITATIONS
OF REMEDIES AND LIABILITY
Limited Warranty. Cascade Designs, Inc. (“Cascade”), to the original owner
(“Owner”), under intended use and maintenance, warrants the enclosed
product (“Product”) to be free from defects in materials and workmanship.
No warranty against defects in materials and workmanship applies if Product is: (i) altered
in any way; (ii) used for purposes inconsistent with Product’s intended purpose or design;
or (iii) improperly maintained. Warranty is furthermore voided where Owner: (i) fails to
follow Product instructions or warnings; or (ii) subjects Product to misuse, abuse, or neglect.
Product parts determined by Cascade to be defective in materials or workmanship will be
repaired or replaced as Owner’s sole remedy. Cascade reserves the right to replace any
discontinued product with a new product of comparable value and function. A returned
product deemed irreparable becomes the property of Cascade and will not be returned.
EXCLUDING THE LIMITED WARRANTY PROVIDED ABOVE, CASCADE, ITS AFFILIATES
AND THEIR SUPPLIERS, TO THE MAXIMUM EXTENT PERMITTED BY LAW, MAKE NO
WARRANTIES, EXPRESSED OR IMPLIED, AND DISCLAIM ALL WARRANTIES, DUTIES
AND CONDITIONS, WHETHER EXPRESSED, IMPLIED, OR STATUTORY, WITH RESPECT
TO THE PRODUCT, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, AGAINST LATENT DEFECTS, FITNESS FOR A PARTICULAR PURPOSE,
OR CORRESPONDENCE TO DESCRIPTION.
Warranty Service. To obtain service under this warranty, the warranty-eligible Product
must be presented to a Cascade authorized dealer. In the United States and Canada,
warranty service may also be obtained by calling 1.800.531.9531 [M-F, 8:00-4:30,
PDT]. Owner is responsible for all costs associated with returning Product to Cascade for
service. Where, at its sole discretion, Cascade deems Product eligible for warranty repair
or replacement, Cascade will pay the shipping and handling associated with returning
repaired or replaced Product to Owner. In instances where Cascade deems a returned
product ineligible for warranty service, Cascade will, if possible, repair product for a
reasonable charge that includes return shipping and handling.
Limitation of Remedies. Should a court of competent jurisdiction find the limited warranty
breached, Cascade’s only obligation will be to, at its option, either repair or replace
Product. Should the aforementioned remedy fail of its essential purpose, Cascade will, in
exchange for return of Product, refund to Owner Product’s original purchase price. THE
FOREGOING REMEDY IS THE SOLE AND EXCLUSIVE REMEDY OF THE PURCHASER
AGAINST CASCADE, ITS AFFILIATES, AND THEIR SUPPLIERS, REGARDLESS OF LEGAL
THEORY.
Limitation of Liability. Cascade’s, its affiliates’, and their suppliers’ maximum liability is
limited to incidental damages not to exceed the original purchase price of the Product.
CASCADE, ITS AFFILIATES AND THEIR SUPPLIERS HEREBY DISCLAIM AND EXCLUDE
ANY LIABILITY FOR ANY CONSEQUENTIAL OR OTHER DAMAGES RESULTING FROM
ANY REASON WHATSOEVER. THIS EXCLUSION AND LIMITATION APPLIES TO ALL
LEGAL THEORIES UNDER WHICH DAMAGES MAY BE SOUGHT, AND WILL APPLY EVEN
IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE.
This limited warranty gives you specific legal rights; you may have additional rights which
vary state to state.
Always completely follow safety, use, operation, and maintenance instructions for this or
any other Cascade product.
European Union customer statutory rights are not affected.
To keep your Guardian Purifier performing reliably for many years, service
your purifier using the Annual Maintenance Kit, available at msrgear.com.
STORAGE
Before storage, pump out any excess water and attach the Clean Side Cover.
DO NOT A dry cartridge will not disassemble and dry the Filter Cartridge.
work properly. (Please contact MSR customer service if you suspect your filter
has dried out.)
Towel dry the outside of the pump. Gently rub off any debris from the Prefilter
and rinse it with fresh water.
Before or after long-term storage, sterilize the purifier to ensure fresh-tasting
water (see “Sterilizing the Purifier”).
STERILIZING THE PURIFIER
When to sterilize: Sterilize the Purifier before and/or after long-term storage to
ensure long life and fresh-tasting water. Also sterilize it before any disassembly.
1. Mix a solution of 2 mL (~1/2 tsp) of household bleach (free of dyes or perfumes)
with 2 L of water, or dissolve 12 MSR Aquatabs® tablets in 2 L of water.
2. Pump most of this solution through the purifier, stopping before air can
enter the pump.
3. Wait 30 minutes.
4. Pump 1-2 liters of clean water to clear any remaining solution from pump.
5. Pump the Handle to purge excess water from the Purifier.
PURIFIER CARE AND MAINTENANCE HOW IT WORKS
The Guardian Purifier’s Hollow Fiber Filter removes pathogens and other
particles through . This is the most reliable means size exclusion purification
of purification because the fibers’ pores physically block pathogens,
including viruses. Pressure forces clean water through the walls of these
fibers. The microbes and dirt left behind are pumped out through the
Dirty Water Outlet Hose.
Other purifiers rely on chemicals or UV light to kill pathogens, or adsorption
(such as carbon) to attract them. While these methods can be effective in clear
water, the Guardian Purifier is reliably effective in all water types – clear,
turbid, tea colored or muddy.
The Guardian Purifier also uses a patent-pending system to self-clean with
every stroke. It does not require in-field cleaning to maintain flow.
REPLACING THE FILTER
CARTRIDGE
The Guardian Purifier’s Hollow Fiber Filter
has been tested to over 10,000 liters.
When to replace: The Filter Cartridge
should be replaced when the flow rate
drops to less than 1L /min. when pumping
70 strokes per minute. The filter is still
purifying water, but more wear occurs on
internal parts as the flow rate drops.
DISASSEMBLY
1. Unthread the Filter Base from Pump
Housing.
ASSEMBLY
1. Lightly lubricate the Filter Cartridge
O-ring and Filter Base O-ring.
3. Thread the Filter Base into the Pump
Housing. Don’t over tighten.
The Filter Base is designed to stop
rotating when it’s fully threaded.
Disassembling the Purifier can expose you to contaminated parts, resulting
in sickness. MSR recommends sterilizing the Purifier before any disassembly.
If you cannot sterilize the Purifier, wash your hands after disassembly. thoroughly
WARNING
ENG
Problem Cause Solution
Decreased/no water flow,
or hard to pump
Clogged Prefilter Rinse/Clean Prefilter
Clogged Filter Replace Filter Cartridge (See
Replacing Filter)
Hose kinked Straighten hose
Limp Handle ( PULL stroke) Damaged Cup Seal Inspect and lube Cup Seal;
replace if necessary. (See
Pump Head Maintenance)
Limp Handle ( PUSH stroke) Piston End Nut leaks Clean Piston End Nut, End Nut
O-ring and Piston O-ring. (See
Pump Head Maintenance)
Damaged or loose
Umbrella Valve
Clean Umbrella Valve; replace
if necessary. (See Pump Head
Maintenance)
Lots of water exiting Dirty
Water Outlet Hose with little
water exiting Clean Water Port
Pressure Relief Valve (PRV)
is contaminated
Clean Relief Valve Assembly;
replace O-ring if necessary.
(See Relief Valve Area
Maintenance)
Clogged Filter Replace Filter Cartridge
Kit Contents Guardian™ Purifier
Instruction Manual
Storage Sack
Weight 17.3 oz. / 490 g
Dimensions 8.2 x 4.7 in. / 21 x 12 cm
Flow Rate 2.5 liters per minute
Hollow Fiber
Filter Up to 10,000+ liters (depends on water conditions)
Patents U.S. patent pending
PRESSURE RELIEF VALVE AREA MAINTENANCE
Dual
Hose
Inlet Hose
Dirty Water
Outlet Hose
Inlet Barb
Prefilter
Dirty Water
Outlet Barb
Clean Side Cover
Clean
Water Port
Handle Float
Step 5
Step 4 Step 6
Step 7
Pump
Housing
Pump Head
Assembly
Pressure
Relief Valve
Relief Valve O-Ring
Umbrella Valve
Handle Pin
Sleeve
Handle Pin
Cup Seal
End Nut O-Ring
Piston End Nut
Pin & Pin Clip
Piston
O-Ring
Piston
Filter
Cartridge
Hollow
Fibers
Filter Base
Cup Seal
Orientation
KNOW YOUR MSR
®
GUARDIAN™ PURIFIER
PURIFIER INTEGRITY TEST FIELD MAINTENANCE
The Guardian Purifier withstands freeze- and drop-testing (6 ft. to concrete),
but if you believe the Filter may have been compromised, an integrity test should
be performed, and can be done in the field. A CLEAR, THREADED WIDE-MOUTH
BOTTLE MUST BE CARRIED TO PERFORM THE TEST. Read all steps first.
The MSR Guardian Purifier is designed to be serviceable in the field.
Please purchase the Annual Maintenance Kit for replacement parts,
available at msrgear.com.
1. Attach threaded container to threaded bottom of purifier.
Or, a hose may be attached to the Clean Water Port.
2. Pump to purify water (~60-80 strokes/min. is optimal).
PURIFY WATER PACK AND STORE PURIFIER
GUARDIAN™ PURIFIER
OPERATING INSTRUCTIONS
PREPARE PURIFIER
1. Uncoil the Dual Hose and place Prefilter in water.
2. Remove RED Clean Side Cover and pump 5-10 strokes
to ensure clean-tasting water.
1. Detach container and remove Prefilter from water.
2. Pump the Handle to purge excess water from purifier.
3. Replace Clean Side Cover & wrap Dual Hose.
WARNING – DO NOT disassemble and attempt to dry out the Filter
Cartridge. See “Replacing the Filter” for more information.
WARNING – DO NOT pump water over 160˚F (71˚C). DO NOT pump
if purifier is frozen. These actions could damage the purifier.
DISASSEMBLY:
1. By hand or using a coin, push and rotate
Relief Valve Assembly 1/3 rotation.
2. Carefully slide Relief Valve Assembly
from cavity.
3. Remove Relief Valve O-ring.
4. Rinse Relief Valve Assembly with clean
water to remove debris.
5. Flush Relief Valve Cavity with clean
water. DO NOT place objects in the
Relief Valve Cavity.
ASSEMBLY:
1. Replace Relief Valve O-ring and apply a
thin layer of Lubricant to it.
2. Verify that the rubber end surface of the
Relief Valve Assembly is clean of debris.
3. Reinstall Relief Valve Assembly by pushing
while rotating it until its arrow aligns
with the arrow and lock symbol on the
Pump Housing.
INSTRUCTIONS:
1. Uncoil Dual Hose and place Prefilter in a
water source.
2. Remove Clean Side Cover and attach clear,
threaded bottle to bottom of purifier.
3. Pump Handle to fill about 1/3 of the bottle
with water.
4. Remove the Prefilter from the water source
and disconnect Dual Hose.
STOP. READ STEPS 5-7 BEFORE PROCEEDING.
5. With threaded container attached,
orient pump upside down, and face
Inlet/Outlet Barbs away from you;
water will be exiting them. Pump
Handle 5-10 strokes until only air
exits the Outlet Barb. (A little water
will drip from the bottle.)
6. Plug Outlet Barb (the smaller hole)
by securely placing a finger over it.
Pump 5-10 complete strokes (one
stroke = complete pump in and out).
7. Keeping Outlet Barb plugged,
observe water in bottle for 30
seconds: If a steady stream of air
bubbles exits the Clean Water Port,
the purifier is NOT SAFE to use.
If a few bubbles escape, pump
the Handle 5 more strokes and
observe another 30 seconds.
If no subsequent bubbles escape,
the pump is safe.
If your Filter Cartridge has been
compromised, please purchase a
replacement at msrgear.com.
TIPS
WATER COLLECTION AND PREPARATION
Use the cleanest, clearest water available.
STORAGE
DO NOT disassemble and attempt to dry out Filter Cartridge. A dry cartridge
will not work properly.
Pump out any excess water from the Purifier prior to storing it.
PREFILTER
The Prefilter is designed to draw water from just below the surface,
where it’s cleanest. Position the Dual Hose and Float such that the
Prefilter’s mesh cage floats vertically under the Float.
In some cases, the mesh cage may rotate partially out of the
water. This is OK. The cage is designed to draw water even when
it’s partially submerged.
If the mesh becomes clogged with debris, swirl it in water and brush the dirt
off. If dirt becomes trapped inside the mesh, remove the Prefilter by gently
twisting and pulling it from the Inlet Hose. Then, rinse the dirt out.
IN FREEZING TEMPERATURES
DO NOT pump the Purifier if its Filter Cartridge is frozen.
The cartridge MUST be fully thawed before pumping.
WARNING WARNING
NOT SAFE
Disassembling the Purifier can expose you to contaminated parts, resulting
in sickness. MSR recommends sterilizing the Purifier before any disassembly.
If you cannot sterilize the Purifier, wash your hands after disassembly. thoroughly
WARNING
PUMP HEAD MAINTENANCE
DISASSEMBLY:
1. Remove Handle Pin (pinch, then push) and Handle Pin Sleeve.
2. Remove Pin & Pin Clip. Set Handle aside.
3. Unthread Piston End Nut and remove Piston assembly.
4. Separate Piston from Piston End Nut.
5. Remove Umbrella Valve by lifting it out with your finger.
6. Note orientation of Cup Seal. Remove all seals
(Cup Seal, Piston O-ring, End Nut O-ring).
7. Rinse all parts with clean water.
ASSEMBLY:
1. Using finger, firmly insert stub end of
Umbrella Valve into center hole of Piston Cavity.
2. Install new End Nut O-ring and Piston
O-ring. Apply a thin layer of MSR Silicone
Lubricant to each.
3. Install new Cup Seal onto Piston in the
same orientation as old Cup Seal.
Apply a thin layer of Lubricant to Cup
Seal and the inside walls of Piston Cavity.
4. Slide Piston End Nut onto Piston.
5. Thread Piston End Nut into Piston Cavity
until rotation stops completely.
6. Reattach Handle with Handle Pin Sleeve
and Handle Pin.
7. Align Piston to Handle and reinstall
Pin & Pin Clip. Confirm that end of
Pin Clip is clipped onto Pin.
Specyfikacje produktu
Marka: | MSR |
Kategoria: | Filtr wody |
Model: | Guardian Purifier |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z MSR Guardian Purifier, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Filtr wody MSR
17 Września 2024
Instrukcje Filtr wody
- Filtr wody Smeg
- Filtr wody Philips
- Filtr wody JBL
- Filtr wody Waterco
- Filtr wody Midea
- Filtr wody Jura
- Filtr wody GE
- Filtr wody BRITA
- Filtr wody Haier
- Filtr wody Fiap
- Filtr wody Grohe
- Filtr wody Juwel
- Filtr wody Ecowater
- Filtr wody Eden
- Filtr wody Oliveri
- Filtr wody Fluval
- Filtr wody Solac
- Filtr wody Verbatim
- Filtr wody Oase
- Filtr wody Terraillon
- Filtr wody Sera
- Filtr wody Consul
- Filtr wody AstralPool
- Filtr wody Jata
- Filtr wody Eldom
- Filtr wody Kent
- Filtr wody Laica
- Filtr wody Imetec
- Filtr wody Zodiac
- Filtr wody T.I.P.
- Filtr wody Everpure
- Filtr wody BWT
- Filtr wody Billi
- Filtr wody LifeStraw
- Filtr wody Baracuda
- Filtr wody Aarke
- Filtr wody Zip
- Filtr wody Aquasure
- Filtr wody ZeroWater
- Filtr wody Beemur
- Filtr wody Tunze
- Filtr wody Aqua Medic
- Filtr wody PUR
- Filtr wody Hydor
- Filtr wody Aquael
Najnowsze instrukcje dla Filtr wody
15 Października 2024
15 Października 2024
15 Października 2024
15 Października 2024
13 Października 2024
11 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024