DC and AC voltage measurement
Connect the black connector to
“COM”, the red connector to the
“VΩHz” socket. Set the function
selector switch to the position. “V”
Normally, the automatic metering
range switch is active, which is
indicated by on the display. “AUTO”
Press the “RANGE“ button to manually
set the measurement range and the
“SELECT“ DC button to select the
and AC modes. Connect the testers in
parallel with the power source for the
measurement time.
DC and AC current measurement
Connect the black wire to “COM” and
the red wire to the or “mA” “10A”
socket, max. 600 mA or for max 10A
measurements. Set the function switch
to the appropriate measuring range,
uA, mA or 10A. Normally, the automatic
metering range switch is active, which
is indicated by on the display. “AUTO”
Press the button to manually “RANGE“
set the measurement range and the
“SELECT“ button to select the DC
and AC modes. Connect the testers in
series to the circuit to be measured.
Frequency and fill factor
measurement
Connect the black connector to
“COM”, the red connector to the
“VΩHz” socket. Frequency and ll
factor measurement available for the
following functions: “V”, “uA”, “mA”,
“10A”, rotate the function selector
switch. Press the button to “SELECT“
set the alternating waveform rst, then
use the button to select the “HZ/%“
measurement. Connect the testers in
parallel with the power source for the
measurement time.
Non-contact frequency measure-
ment
Connect the red connector to the
“VΩHz” socket. Turn the function
selector switch to the NCF mode
and then approach the front of
the instrument (NCV/NCF) to 1-2
centimeters to the wire to be
measured. The measured value can be
read from the display.
Non-contact AC voltage detection
Turn the function selector switch to
NCV mode and then approach the
front of the instrument (NCV/NCF)
to 1-2 centimeters to the wire to be
measured. In the case of detection,
the display of the instrument ashes
red and beeps intermittently. The more
often there is a sound and light signal
the better the result. The display shows
4 horizontal lines indicating the hit,
the higher the value being the more
secure.
Resistance, tear and diode, capacity
measurement
Connect the black connector
to “COM”, the red connector
EN USER MANUAL
to the “VΩHz” socket. Turn
the function selector switch to
„ ”. Use the button “SELECT“
to set the measurement type. For
diode measurement, the instrument
shows the opening voltage of the
diode or in the closing direction. “OL”
In case of a break test, the instrument
outputs a beeping sound if the
measured value is less than 50 ohms.
For resistance measurements, wait
for a few seconds for measurements
of mega ohm while the measured
value is stabilized on the display. By
pressing the button you can “RANGE“
manually select the measuring range,
press and hold to return to automatic
mode. Before capacitor measurement,
discharge the capacitors in any case,
otherwise the voltage stored inside
them can damage the instrument. For
larger capacities, the measurement
may take several seconds.
Display maximum and minimum
values
After nishing measurements, you
have the option of calling the largest,
smallest, and dierent values. Press
the “MAX/MIN“ button to display the
desired value. MAX - maximum, MIN -
minimum, MAX-MIN - dierence value
Relative measurement method
During measurement, press the
“REL“ button to activate the relative
measurement, the instrument from
there uses the previous measurement
as a starting point.
Data hold
During measurement, press the
“HOLD“ button so that the measured
value remains on the display even after
removing the measuring testers. Press
again to reset the measurement.
Backlight
To turn on the backlight, press the
“HOLD“ button for a long time. It will
switch o approx. after 15 seconds, it is
automatically turns o.
Automatic switch off
The instrument automatically switches
o for approx. after 5 minutes. Press
“SELECT“ repeatedly to switch on.
Smart mode, wireless Bluetooth
connection
The instrument is suitable for storing
and displaying measurements on an
external device. In any mode of the
instrument, press and hold the “TX“
button for a long time. The Tx display
on the display indicates the activation
of the wireless Bluetooth connection.
An app for Android and iOS can
be downloaded from Play Market
and AppStore: „MAXWELL
MULTIMETERS”
Specyfikacje produktu
Marka: | Maxwell |
Kategoria: | multimetr |
Model: | MX-25521 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Maxwell MX-25521, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Maxwell
6 Października 2024
16 Września 2024
6 Sierpnia 2024
4 Lipca 2024
2 Lipca 2024
Instrukcje multimetr
- multimetr PeakTech
- multimetr Joy-It
- multimetr Voltcraft
- multimetr Milwaukee
- multimetr GW Instek
- multimetr Stanley
- multimetr Silverline
- multimetr Testo
- multimetr Aim TTi
- multimetr TFA
- multimetr Chauvin Arnoux
- multimetr Gembird
- multimetr Uni-T
- multimetr Owon
- multimetr Digitus
- multimetr Vimar
- multimetr Emos
- multimetr Sonel
- multimetr Trotec
- multimetr Velleman
- multimetr Pyle
- multimetr Gossen Metrawatt
- multimetr Fluke
- multimetr Megger
- multimetr Weidmüller
- multimetr BENNING
- multimetr Brandson
- multimetr Metrix
- multimetr Rigol
- multimetr Ferm
- multimetr Extech
- multimetr Testboy
- multimetr Kyoritsu
- multimetr Klein Tools
- multimetr Powerfix
- multimetr Workzone
- multimetr Alecto
- multimetr Monacor
- multimetr Etekcity
- multimetr HT Instruments
- multimetr Qian
- multimetr Beha-Amprobe
- multimetr Laserliner
- multimetr Ideal
- multimetr Profile
- multimetr Appa
- multimetr Amprobe
- multimetr Tacklife
- multimetr Somogyi
- multimetr Steren
- multimetr Flir
- multimetr Topcraft
- multimetr Altai
- multimetr Plieger
- multimetr Cablexpert
- multimetr Greenlee
- multimetr Högert
- multimetr Wago
- multimetr REV
- multimetr Bruder Mannesmann
- multimetr Keithley
- multimetr Bearware
- multimetr Metrel
- multimetr Multimetrix
- multimetr Digi-tool
- multimetr Skandia
- multimetr Elma
- multimetr Kewtech
- multimetr Strex
- multimetr Mastech
- multimetr MBS
- multimetr MGL Avionics
- multimetr PCE Instruments
- multimetr Micronta
- multimetr CEM
- multimetr Horex
- multimetr Cosinus
- multimetr Kurth Electronic
- multimetr Weltron
- multimetr Sanwa
- multimetr Rohde & Schwarz
- multimetr EEVBlog
- multimetr Kingcraft
- multimetr Caltek
- multimetr Elworks
- multimetr Noyafa
Najnowsze instrukcje dla multimetr
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
8 Października 2024
7 Października 2024
5 Października 2024
5 Października 2024