Instrukcja obsługi Maxwell MX-25201
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Maxwell MX-25201 (9 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/9

U Mser anUal
Használati Utasítás
ManUal de Utilizare
Užívateľská prírUčka
DIGITAL MULTIMETER
DIGITÁLIS MULTIMÉTER
MULTIMETRU DIGITAL
DIGITÁLNY MULTIMETER
Product code / Termékkód / Cod produs / Kód produkta:
25201
EN
HU
RO
SK
i
VC890C+

EN User Manual
sUMMary
This broad-spectrum measurement device
enables you to measure DCV, ACV, DCA, ACA,
resistance, capacity, diode, transistor, continuity
and temperature. Ideal for using in laboratories,
factories and even at home.
s afety reMarks
This device complies to the IEC10101 standards.
Read the manual carefully before use.
• Do not measure a higher value than the set
range.
• To avoid electric shock make sure that the
measuring wires are intact.
• Disconnect the measuring wires while
changing function.
• Select the proper function and range, avoid
incorrect usage.
• Do not use the device if the battery holder lid
and back cover are not in their places.
• Do not measure voltage while in resistance
measuring mode.
• Remove the wires and turn the device o
before replacing the battery or fuse.
• Safety signs:
Dangerous voltage
Grounding
Double insulation
Low battery power
CHaraCteristiCs
Display LCD display
Max. value display: 4 digit automatic
polarity display
Low battery power
display
Operating
environment (0-40) °C, R. H. 80%.
Battery
9V X 1 (NEDA
1604/6F22 or same
type)
Dimensions 175 X 93 X 55 mm
Weight 400g (with battery)
t eCHniCal data
DCV
Range Accuracy Resolution
200mV
±0.5%
100μV
2V 1mV
20V 10mV
200V 100mV
1000V ±0.8% 1V
Input resistance: 5m Ω at mV range , other
ranges: 10 mΩ
ACV
Range Accuracy Resolution
2V
±0.8%
1mV
20V 10mV
200V 100mV
750V ±1.2% 1V
Input resistance: 10MΩ
Overload protection: 1000V DC or AC peak value
Frequency response : (40~200)Hz
DCA
Range Accuracy Resolution
200μA ±0.8% 100nA
20mA 10μA
200mA ±1.2% 100μA
20A ±2.0% 10mA
Max. inward current
20A (testing time
should be 10 sec
max)
Fuse 0,2A/250V and 20A /
250 V fast fuse

EN User Manual
DCV measuring
• Connect the black measuring wire to the
„COM” connector, and the red one to the „V/Ω”
connector.
• Set the function switch to the proper DCV
setting, and connect the wires to the circuit.
Note:
• If you are unsure about the measured voltage range, set
the function switch to a high range.
• If the LCD shows „1” it means overload, and the range
should be set to a higher value.
ACV measuring
• Connect the black measuring wire to the
„COM” connector, and the red one to the „V/Ω”
connector.
• Set the function switch to the proper ACV
setting and connect the wires to the circuit.
Note:
• If you are unsure about the measured voltage range, set
the function switch to a high range.
• If the LCD shows „1” it means overload, and the range
should be set to a higher value.
DCA measuring
• Connect the black measuring wire to the
„COM” connector, and the red one to the „mA”
connector (max. 200mA), or connect the red
wire to the „20A” connector (max. 20A).
• Set the function switch to the proper DCA
setting and connect the wires to the circuit.
Note:
• If you are unsure about the measured voltage range, set
the function switch to a high range.
• If the LCD shows „1” it means overload, and the range
should be set to a higher value.
• Max inward current 200mA or 20A (depending on the
placement of the red wire), in case of an exceeding
current the fuse will melt.
ACA measuring
• Connect the black measuring wire to the
„COM” connector, and the red one to the „V/Ω”
connector.
• Set the function switch to the proper ACA
setting, and connect the wires to the circuit.
Note:
• If you are unsure about the measured voltage range, set
the function switch to a high range.
• If the LCD shows „1” it means overload, and the range
should be set to a higher value.
• Max inward current 1000V.
Resistance measuring
• Connect the black measuring wire to the
„COM” connector and the red one to the V/Ω
connector.
• Set the function switch to the proper
resistance setting and connect the wires to the
measured resistor.
Note:
• If the measured resistance value is over the chosen max
value the LCD will show „1” and the function switch
needs to be set to a higher range. It may take a few
seconds for the device to stabilize when measuring
above 1MΩ
Capacity measuring
• Connect the wire to the „V/Ω „ connector and
the red one to the „COM” connector.
• Set the function switch to a proper capacity
setting and connect the wires to the measured
capacitor.
Note:
• If you are unsure about the measured capacity set the
function switch to a high range.
• If the LCD shows „1” it means overload and the function
switch needs to be set to a higher range.
• To be safe, discharge the measured capacitor before
measuring.
Diode and continuity test
• Connect the black measuring wire to the
„COM” connector, and the red one to the „V/Ω”
connector (Note: the red wire's polarity is „+”)
• Set the function switch to the „ ” position,
connect the wires to the measured diode.
• Connect the wires to the diode's measuring
points, if the device beeps, the resistance is
lower than appr. (70±20)Ω
Temperature measuring
• Connect the red wire to the mA, and the black
one to the "COM" connector. Touch the end
of the thermometer to the measured object
and the temperature value is displayed on the
screen in degrees Celsius.
hFE
• Set the function switch to hFE.
• Place the part into the transistor connector
depending on whether it is NPN or PNP type.
Automatic turn-o
• If the device is not used for 15 minutes it turns
o automatically. To use it again, turn the
function switch.
Specyfikacje produktu
Marka: | Maxwell |
Kategoria: | multimetr |
Model: | MX-25201 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Maxwell MX-25201, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Maxwell

6 Października 2024

16 Września 2024

31 Sierpnia 2024

30 Sierpnia 2024

24 Sierpnia 2024

23 Sierpnia 2024

20 Sierpnia 2024

15 Sierpnia 2024

14 Sierpnia 2024

13 Sierpnia 2024
Instrukcje multimetr
- multimetr PeakTech
- multimetr Joy-It
- multimetr Voltcraft
- multimetr Milwaukee
- multimetr Yato
- multimetr Parkside
- multimetr GW Instek
- multimetr Stanley
- multimetr Silverline
- multimetr Testo
- multimetr Aim TTi
- multimetr TFA
- multimetr Chauvin Arnoux
- multimetr Gembird
- multimetr Uni-T
- multimetr Owon
- multimetr Biltema
- multimetr Digitus
- multimetr Vimar
- multimetr Schneider
- multimetr Emos
- multimetr Sonel
- multimetr BaseTech
- multimetr Perel
- multimetr Trotec
- multimetr Velleman
- multimetr Pyle
- multimetr Gossen Metrawatt
- multimetr Fluke
- multimetr Megger
- multimetr Weidmüller
- multimetr BENNING
- multimetr Brandson
- multimetr Metrix
- multimetr Rigol
- multimetr Abus
- multimetr Elro
- multimetr Ferm
- multimetr Hager
- multimetr Extech
- multimetr Testboy
- multimetr Kyoritsu
- multimetr Klein Tools
- multimetr Powerfix
- multimetr Workzone
- multimetr Alecto
- multimetr JUNG
- multimetr Monacor
- multimetr Etekcity
- multimetr Wiha
- multimetr HT Instruments
- multimetr Qian
- multimetr Beha-Amprobe
- multimetr Clas Ohlson
- multimetr Laserliner
- multimetr Ideal
- multimetr Profile
- multimetr Aldi
- multimetr Appa
- multimetr Amprobe
- multimetr Amiko
- multimetr Brennenstuhl
- multimetr Tacklife
- multimetr Somogyi
- multimetr Steren
- multimetr Flir
- multimetr Topcraft
- multimetr Altai
- multimetr Plieger
- multimetr Projecta
- multimetr Cablexpert
- multimetr Greenlee
- multimetr Högert
- multimetr Wago
- multimetr REV
- multimetr Bruder Mannesmann
- multimetr Keithley
- multimetr Bearware
- multimetr Metrel
- multimetr Multimetrix
- multimetr Digi-tool
- multimetr Skandia
- multimetr Elma
- multimetr Testec
- multimetr Hubinont
- multimetr Kewtech
- multimetr Strex
- multimetr Mastech
- multimetr MBS
- multimetr MGL Avionics
- multimetr PCE Instruments
- multimetr Micronta
- multimetr CEM
- multimetr Horex
- multimetr Cosinus
- multimetr Kurth Electronic
- multimetr IWH
- multimetr Weltron
- multimetr Sanwa
- multimetr Rohde & Schwarz
- multimetr EEVBlog
- multimetr Kingcraft
- multimetr Caltek
- multimetr Elworks
- multimetr Noyafa
Najnowsze instrukcje dla multimetr

14 Marca 2025

14 Marca 2025

14 Stycznia 2025

12 Stycznia 2025

10 Stycznia 2025

10 Stycznia 2025

10 Stycznia 2025

10 Stycznia 2025

10 Stycznia 2025

8 Stycznia 2025