U ser manUal
Használati Utasítás
manUal de Utilizare
Užívateľská prírUčka
DIGITAL MULTIMETER
DIGITÁLIS MULTIMÉTER
MULTIMETRU DIGITAL
DIGITÁLNY MULTIMETER
Product code / Termékkód / Cod produs / Kód produkta:
25304
HU
RO
SK
i
VC9808+
EN
EN User Manual
G eneral description
Display
4 digit liquid crystal
display max. value
9999
Polarity Automatic negative
polarity display
Nullication automatic
Measurement
process A/D converter
Overload display
only OL
is displayed
Low battery power The( ) symbol
appears on the screen
Safety
prescriptions
CE EMC/LVD. Device
complies to IEC1010
standard
Protection
category II, double insulation
Operating
environment
temperature: 0…40
°C, relative humidity:
< 80%
Storage
environment
temperature: -20…60°C,
relative humidity:
< 80%
Battery 1 x 9V IEC 6F22 Battery
Dimensions 190 mm x 88,5 mm
x 27,5 mm
Weight 422 g (with battery)
Accesories
Instructions,
connection cable (red
and black, 1 pair),
hitting pocket
protector, K-type
thermometer probe
e lectrical
cHaracteristics
Accuracy +/- (% of displayed value + number of
digits) at 23 +/-5 °C, < 75% relative humidity
DCV
Range Accuracy Resolution
200 mV
+/- (0,5% + 3)
0,1 mV
2 V 1 mV
20 V 10 mV
200 V 100 mV
1000 V 1 V+/- (0,8% + 10)
Input
Impedance 10 MΩ
Overload
protection
(Range: 200 mV)
1000 VDC or AC peak
value
250 VDC or AC peak value
ACV
Range Accuracy Resolution
200 mV
+/- (0,8% + 5)
0,1 mV
2 V 1 mV
20 V 10 mV
200 V 100 mV
750 V 1 V+/- (1,2% + 10)
Input Impedance 10 MΩ
Frequency response
40 Hz - 1 KHz
(sine wave and
triangular wave)
40 Hz - 200 Hz
(other waves)
DCA
Range Accuracy Resolution
2 mA
+/- (0,8% +10)
1 μA
20 mA 10 μA
200 mA 100 μA
20 A +/- (2% + 5) 10 mA
Overload
protection
20 A / 250 V fuse with
"F" mark
200 mA / 250 V fuse with
"F" mark
User Manual EN
ACA
Range Accuracy Resolution
2 mA
+/- (0,8% + 10)
1 μA
20 mA 10 μA
200 mA 100 μA
20 A +/- (2% + 5) 10 mA
Overload
protection
20 A / 250 V fuse with
"F" mark
200 mA / 250 V fuse with
"F" mark
Frequency response
40 Hz - 1 KHz
(sine wave and
triangular wave)
40 Hz - 200 Hz
(other waves)
Capacitance
Range Accuracy Resolution
20 nF
+/- (3,5% + 20)
10 pF
200 nF 100 pF
2 μF 1 nF
20 μF 10 nF
200 μF +/- (5% + 10) 100 nF
2000 μF 1 μF
Overload protection DC 250V or AC peak
value
Transistor hFE-Test
Function Description Test state
hFE
The amplication
factor of the transis-
tor is measured
(0-1000)
(NPN or PNP)
Base current
appr. 10 μA
VCE appr.
3 V
Resistance
Range Accuracy Resolution
200 Ω +/- (0,8% + 5) 0,1 Ω
2 kΩ
+/- (0,8% + 3)
1 Ω
20 kΩ 10 Ω
200 kΩ 100 Ω
2 MΩ 1 kΩ
20 MΩ
+/- (1,0% + 25)
10 kΩ
Overload protection 250 V DC or AC peak
value
The reading be displayed slowly when the
measurement is more than 1 MΩ. Please wait it to be
stable.
Temperature (with a K type temperature
sensor)
Range Accuracy Resolution
-20 °C - 1000 °C +/- (1,5%+15) 1°C
0 °F - 1832 °F 1 °F
Diode and Continuity Testing
Function Reading Condition
Forward voltage
drop of diode
Forward DCA is
approx. 1 mA,
the backward
voltage is
approx. 3 V
Buzzer makes a
long sound while
resistance is less
than
70 Ω +/- 20 Ω
Opening volta-
ge appr. 3 V
Overload protection 250 V DC or AC peak
value


Specyfikacje produktu

Marka: Maxwell
Kategoria: multimetr
Model: MX-25304

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Maxwell MX-25304, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje multimetr Maxwell

Instrukcje multimetr

Najnowsze instrukcje dla multimetr

Voltcraft

Voltcraft PMM 3005-20 Instrukcja

9 Października 2024
Bearware

Bearware 306998 Instrukcja

9 Października 2024
Bearware

Bearware 307001 Instrukcja

9 Października 2024
Fluke

Fluke 283 FC Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5330C Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5310B Instrukcja

9 Października 2024
Emos

Emos M3216 Instrukcja

8 Października 2024
Uni-T

Uni-T UT121B Instrukcja

7 Października 2024
Velleman

Velleman DVM840 Instrukcja

5 Października 2024
Velleman

Velleman DVM852 Instrukcja

5 Października 2024