For your convenience, write down the following
information. If you call our Consumer Hotline,
these are the first questions you will be asked.
Lithium (non-replaceable sealed in) Battery-Operated
Smoke Alarm with Alarm Memory and SMART HUSHTM
Control to temporarily silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important
part of your family’s home safety plan. You can trust this
product to provide the highest quality safety protection. We
know you expect nothing less when the lives of your family
are at stake.
Smoke Alarm User Guide
Date Code (located on back of alarm):
The National Fire Protection Association
(NFPA) and the manufacturer
recommend replacing this alarm
ten years from the date code.
Date of Purchase:
Where Purchased:
User Guide P/N 21008311-EN Rev.C
0910-7216-04
i9010 For model: i9010
This alarm detects products of combustion using the ionization
technique. It contains 0.9 microcurie of Americium 241, a
radioactive material (see Section 9). Distributed under U.S. NRC
License No. 32-23858-01E. Manufactured in compliance with U.S.
NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from
any regulatory requirements. Do not try to repair the smoke alarm
yourself. Refer to the instructions in Section 12 for service.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE
INSTALLATION AND KEEP THIS USER GUIDE NEAR THE
ALARM FOR FUTURE REFERENCE.
CONTENTS OF THIS USER GUIDE
1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- BATTERY
7 -- PERMANENTLY DISABLE ALARM / DISCHARGE BATTERY
8 -- MAINTENANCE
9 -- LIMITATIONS OF SMOKE ALARMS
10 -- GOOD SAFETY HABITS
11 -- NRC INFORMATION
12 -- NFPA PROTECTION STANDARD 72
13 --
CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION
14 -- FCC
15 -- SERVICE AND WARRANTY
1. RECOMMENDED LOCATIONS FOR ALARMS
Locate the first alarm in the immediate area of the bedrooms.
Try to monitor the exit path as the bedrooms are usually farthest
from the exit. If more than one sleeping area exists, locate
additional alarms in each sleeping area.
Locate additional alarms to monitor any stairway as stairways act
like chimneys for smoke and heat.
Locate at least one alarm on every floor level.
Locate an alarm in every bedroom.
Locate an alarm in every room where electrical appliances are
operated (i.e. portable heaters or humidifiers).
Locate an alarm in every room where someone sleeps with the
door closed.
The closed door may prevent an alarm not located in that room
from waking the sleeper.
Smoke, heat, and combustion products rise to the ceiling and
spread horizontally. Mounting the smoke alarm on the ceiling in
the center of the room places it closest to all points in the room.
Ceiling mounting is preferred in ordinary residential
construction.
For mobile home installation, select locations carefully to avoid
thermal barriers that may form at the ceiling. For more details, see
MOBILE HOME INSTALLATION below.
When mounting an alarm on the ceiling, locate it at a minimum of
4” (10 cm) from the side wall (see figure 1).
When mounting the alarm on the wall, use an inside wall with
the top edge of the alarm at a minimum of 4” (10 cm) and a
maximum of 12” (30.5 cm) below the ceiling (see figure 1).
Put smoke alarms at both ends of a bedroom hallway or large
room if the hallway or room is more than 30 feet (9.1 m) long.
(10 cm)
4"
MINIMUM
(10 cm)
4"
CEILING
DEAD AIR
SPACE
SIDE
WALL
MINIMUM
(30.5 cm)
12"
MAXIMUM
BEST
HERE NEVER
HERE
ACCEPTABLE
HERE
FIGURE 2 FIGURE 3
FIGURE 1
(0.9 m)
3'
(102 mm)
4"
NOT
IN THIS
AREA
ANYWHER E
IN THIS AREA
(0.9 m)
3'
(0.9 m)
3'
(102 mm)
4"
NOT
IN THIS
AREA
ANYWHERE
IN THIS
AREA
ANYWHERE ALONG
THIS BOLD SURFACE
30.5 cm
Locations permitted for smoke
alarms and smoke detectors
on tray-shaped ceilings.


Specyfikacje produktu

Marka: Kidde
Kategoria: Detektor dymu
Model: i9010

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kidde i9010, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Detektor dymu Kidde

Kidde

Kidde 3SFWR Instrukcja

9 Października 2024
Kidde

Kidde KF30R Instrukcja

9 Października 2024
Kidde

Kidde P4010ACS-WCA Instrukcja

9 Października 2024
Kidde

Kidde P4010DCSCO-WCA Instrukcja

9 Października 2024
Kidde

Kidde i12020CA Instrukcja

9 Października 2024
Kidde

Kidde i12040CA Instrukcja

9 Października 2024
Kidde

Kidde KF20R Instrukcja

9 Października 2024
Kidde

Kidde CP9000CA Instrukcja

9 Października 2024
Kidde

Kidde Pi2010CA Instrukcja

9 Października 2024
Kidde

Kidde KN-COSM-B-RF-CA Instrukcja

9 Października 2024

Instrukcje Detektor dymu

Najnowsze instrukcje dla Detektor dymu

First Alert

First Alert HD6135FB Instrukcja

14 Października 2024
Qolsys

Qolsys QS5210-840 Instrukcja

9 Października 2024
Elro

Elro FS151021M Instrukcja

9 Października 2024
Nedis

Nedis WIFIDS21WT Instrukcja

8 Października 2024
SAVS

SAVS S10 Instrukcja

8 Października 2024
Emos

Emos P56400S Instrukcja

8 Października 2024
TFA

TFA AirCo2ntrol Life Instrukcja

8 Października 2024
Kogan

Kogan KASMKALMRFA Instrukcja

7 Października 2024
Kogan

Kogan KASMKALMRMA Instrukcja

7 Października 2024