• Smoke entering the room from the firebox when the door is open may be caused by
Insufficient length of flue (Flue to be 4500mm minimum from underneath base of heater to underside of cowl)
– Increase height of flue.
• Flue downdraught
– Consult dealer or increase height of flue.
• Creosote build up in flue
– Remove cowl and clean flue as per cleaning instructions. Check moisture content of wood.
• Excessive ash build up
Some woods will give large amounts of ash despite how you run the heater. Others will give you very little. Use the
wood which is most convenient for you as long as it is dry. After a period of time you will get to know when to
empty your unit. Always leave 12mm of ash in the bottom of your heater. Bark will give you excessive ash. Try not to
burn it.
If you are burning wood that gives you charcoal, you may find that after running the heater say for 8 hours at
maximum burn rate, the charcoal builds up excessively. Overnight burn will reduce this charcoal back to a fine ash. If
you are not ready to shutdown for overnight burn when you next fuel the stove, load the stove with only one piece
of wood and lay it across the firebox on top of the charcoal. Open the air control wide open and you will find the
charcoal will burn down with the one piece of wood. Repeat the process until the ash level is significantly reduced.
Sturt Mk2 Freestanding
8
Troubleshooting (Continued)
1. Subject to clauses 2 & 3 of this warranty, A.F. Gason Pty Ltd ACN 004 667 556 (Gason) warrants the following components of its heaters against defects in workmanship
and/or materials for the following periods from the date of purchase:
(a) the firebox for ten years;
(b) the paint finish for a period of twelve months if the purchaser has followed the instructions provided by Gason in this Operation and Installation Instructions manual; and
(c) all other components for twelve months except the glass, fire brick lining or baffle plate if, in the opinion of Gason, these items have been damaged by impact.
2. This extended warranty does not apply:
(a) if the heater is purchased from a person who has not been authorised by Gason to sell its products;
(b) if, in the opinion of Gason, the heater or any component has been subjected to abuse, misuse, alteration, modification or has not been installed, operated or maintained in
accordance with the instructions provided by Gason; or
(c) to owners other than the original purchaser.
3. If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this warranty, please contact an authorised Gason service
centre to arrange for an assessment.
4. If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretion:
(a) replace the heater;
(b) repair or replace specific components of the heater; or
(c) provide a full refund.
5. Parts replaced under this warranty are warranted for the balance of their original warranty period.
6. If, at the discretion of Gason the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this
warranty must pay all costs associated with:
(a) returning the heater; and
(b) the delivery or collection of any new or repaired heater.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and
the failure does not amount to a major failure.
Any benefits you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under a law in relation to the heater to which
these warranties relate.
These warranties are given by:
A.F. Gason Pty Ltd
Blake Street
Ararat VIC 3377
Please contact us if you have any queries on:
Phone: 03 5352 2151;
or email us via the “Contact Us” section of our website: www.gason.com.au.
Jindara Heating reserves the right to modify or alter specifications, materials, etc. in the interest of product improvement.
WARRANTY
Sturt Mk2 Freestanding
7
Troubleshooting
Air Control Jamming
Remove air control cover plate by removing the two screws which hold it onto the face of the heater. There are two bolts
holding the air slide in place. Undo them and remove the air slide. Wipe any ash or dust that may have accumulated on the
back of the air slide or on the face of the heater. If any burrs have developed on the back of the air slide or on the face of the
heater, rub them off with fine wet and dry sand paper till you have a smooth surface and edges. Replace the air slide and
make sure the washers and spacers are on the bolts when you screw the bolts back into the face of the heater. Do not apply
any type of lubricant to the air slide whatsoever as this will attract dust and make the slide stick.
No Overnight Burn
Remove the air slide as per air control jamming and check that the air slide is hard against the face of the heater. If it is loose,
tighten up the bolts holding the air slide to the face of the heater. Do not overtighten.
Check that the door rope has an even indentation from the sealing strip, which is on the face of the firebox. If it is uneven and
it appears as though air could leak through the seal, adjust the thickness of the door rope to suit. Stretch the rope to make it
thinner where the indentation is the heaviest and bunch up the excess where the indentation is smaller.
Check the four bolts that hold the glass retainer in position. If loose tighten. Do not overtighten.
The door may become loose through the door seal shrinking. To tighten the door, open the door and look at the inside of the
door catch. Undo the nut which is holding the latch plate. Remove the latch plate. Remove one thick washer and the star
washer. Refit the latch plate. The latch plate is concave to provide a lead in edge so that there is smooth connection between
the door latch and the catch. Make sure that the face of the latch that is curved outward is facing towards the door.
Replace the nut. When closing the door you should now feel firm resistance when the latch comes into contact with the catch.
Noisy Fan (when optional Fan fitted)
Turn the power off and remove the three pin plug from the power point.
At the lower rear of the heater, removed the four screws which attach the fan assembly to the heater and remove fan.
Clean any dust with a dry paint brush and vacuum the fan blades. Clean around the motor. After completion place two or
three drops of sewing machine oil on the shafts at the bearings. Replace the fan in reverse to the removal.
Fan not working (when optional Fan fitted)
Check the power connection with another appliance. If the power point is okay assume the fan or the switch is defective.
Isolate the power as above. Check that the terminals on the loom and switch are firmly connected. If the fan then fails to
function, remove the fan as per above instruction and convey the same to authorized Jindara/Eureka dealer from whom you
purchased you unit for service. Replace in the reverse order.
!
WARNING
NEVER OPERATE THE HEATER WITH THE DOOR LOOSE AND NOT AIR TIGHT.
OVERFIRING COULD RESULT IN DETRIMENTAL WEAR AND TEAR ON THE
FIREBOX.
Overfiring
!
WARNING
Leaving Door Open
As stated previously in relation to leaving door open 25mm to encourage the fire
to pick up at a faster rate. Your heater has been tested to ensure that no
structural damage can take place if the door is inadvertently left open. However
your paint finish can be damaged if the door is left open for a long period with a
full firebox of fuel. Closely supervise your heater while the door is left open.
Closing the Door
Always ensure that before you close your door there is no wood protruding
beyond the front of the firebox opening. Do not use the door glass as a ’battering
ram’ to push the wood back into the firebox. Damage to the glass by such
impact is not covered by your warranty.
The Door
Sturt Mk2 Freestanding
2
!
WARNING
Read and follow these instructions carefully before installing and using
this appliance.
SAVE THESE INSTRUCTIONS
Paint Curing and Care
!
WARNING
A flue fire with resulting damage may occur if this appliance is not installed,
operated and maintained as per this booklet.
Never place combustible material such as wood, paper or furniture near the
appliance.
This appliance is designed to burn dry wood. Do not burn rubbish, driftwood,
flammable liquids or any substance containing salts or corrosives.
This appliance must not be installed and operated in an area where kerosene,
petrol, paint thinner or other flammable liquid is used or stored.
The flue system must be inspected and cleaned annually or sooner if required.
Failure to do so could result in an excessive build up of creosote which may
result in a flue fire which may damage the flue or cause damage to your
home.
The surface of the appliance becomes hot during operation. Do not touch the
surface of this appliance. Keep children away from the appliance during
operation. Do not allow anyone to operate this appliance who is not familiar
with the instructions in this booklet.
!
WARNING
Your heater is coated with the best available heat resistant paint. Even though
the paint has been baked after application, it may require further temperature
curing. It may, if you overfire the heater on its first fire, discolour. For your first
two or three firings, never exceed medium air setting. Do not wipe the heater
while the paint is curing. After the paint has cured the only maintenance required
to maintain the heaters finish is to wipe it with a soft cloth. Do not use any
commercial cleaners or solvents on the paint finish.
We are proud of the presentation of our products. If at any time you need to
freshen up the paint finish, your local dealer has touch up paint available for
purchase. You may even change the colour of your heater if you wish.
If you have any enquires, please contact the dealer from whom you purchased your heater:
PLEASE COMPLETE:
Dealer Name
Dealer Address
Phone
Please attach your original purchase dockets to this booklet for future reference.
Safety Warnings
Sturt Mk2 Freestanding
3
Installation
The Jindara Sturt Mk2 conforms to AS/NZS 2918:2001 Appendix B when placed in the above position on a minimum
hearth or floor protector of 910mm deep x 770mm wide x 9mm thickness. The floor protector should extend mm 350
in front of the appliance base.
Hearth Requirements
Rear Wall
170mm
170mm
Side Wall
Rear Wall
50mm
550mm
Corner installation
flue protection not required
Side Wall
Clearances to combustibles & flue requirements
It is recommended that you either use the flue kit that was tested in the test report number shown below, or an
approved Australian Standard flue kit, (that incorporates a decorative surround which is unperforated for 180 degrees
of its circumference) in conjunction with an additional 180 degree x 900mm stainless steel flue shield between
decromesh casing and active flue (supplied with wood heater).
The Jindara Sturt Mk2 Freestanding has been tested to the AS/NZS 2918:2001 Appendix B Test Report Number HCMG-
15-062.
The Jindara Sturt Mk2 Freestanding heater conforms to the Australian Standard in the following placement of the
appliance in relation to combustible surfaces.
Floor Protector Floor Protector
!
WARNING
THE INSTALLATION OF THIS APPLIANCE MUST BE CARRIED OUT AS PER THIS
MANUAL AND THE FLUE MANUFACTURER’S SPECIFICATIONS.
WE RECOMMEND THAT YOU USE A QUALIFIED INSTALLER TO CARRY OUT
THE INSTALLATION.
If you have any other enquiries, please contact the dealer from whom you
purchased your heater.
THIS APPLIANCE WEIGHS IN EXCESS OF 120 KILOGRAMS. EXTREME CARE
SHOULD BE TAKEN WHEN HANDLING THE APPLIANCE.
Installation
Sturt Mk2 Freestanding
6
Operating your Jindara (Continued)
Overnight burn
Approximately 30 minutes before turning the heater down to overnight burn it is recommended to load the heater with
fuel for the overnight burn. Leave the air control in the medium to high position. Let the heater run for about thirty
minutes. This will reduce the moisture content in the fuel before shut down. (This will help reduce the creosote formation
in the firebox and flue.) Set the air control to the setting you have found best for your requirements which is normally
about 8mm to the right of full shut down. The aim when overnight burning is to have only a few hot embers left in the
bottom of the firebox in the morning, not huge lumps of wood.
Cleaning your flue
Carefully remove baffle plate and put it to one side. Close the heater door. Obtain a 150mm flue brush from your local
Jindara Dealer and proceed up onto your roof. Remove the cowl. Slowly push the flue brush down the chimney until it
stops. Pull the brush back out and repeat the process. Each time you do this you will notice that the brush will go further
down the chimney till it reaches the bottom. The soot and creosote will fall down the chimney and into the firebox. Clean
residue from firebox. Replace the baffle plate. Make sure you do the job well. The cleaner the flue the less chance there
will be of the creosote sticking again. After you have replaced the cowl, inspect the roof flashing for any damage that
may have been incurred whilst you were cleaning the flue. Reseal the seal on the roof with roof and gutter silicone if
required.
Using your Jindara as a cooking appliance
COOKING
The front section on the top of the heater is the external surface of the firebox. When you require a fast increase in
temperature or continuous high heat, place your cooking vessel or kettle there. If you want to simmer, place the cooking
vessel or the kettle on the shelf at the rear of the heater.
CLEANING
If spillage occurs wipe the heater with a soft cloth. If something sticks to the heater, leave it and it will eventually burn
off.
It is recommended to use a stove mat to protect the top of the heater. An ideal stove mat is a 150mm x 150mm quarry
tile. Buy a quarry tile that suits your application. You will find that the bottom of the tile will have an uneven surface.
Grind them off so that you have a flat surface and then place the tile onto the firebox top. You can now place your kettle
onto the tile.
If you mark or damage the paint finish, you can easily renew the heater’s appearance by using touch up paint available
from your authorized Jindara Dealer.
The Fan (when optional Fan fitted)
It is recommended to run the fan while the heater is operating above Low burn on Low speed. For extended periods
when the heater is running above Medium fire, fan speed High or Boost is recommended for short bursts where a quick
temperature rise is desired in conjunction with a high fire setting. The fan should be cleaned on a regular basis. (refer
Troubleshooting for fan removal and cleaning.)


Specyfikacje produktu

Marka: Jindara
Kategoria: Podgrzewacz
Model: Sturt

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Jindara Sturt, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Podgrzewacz Jindara

Jindara

Jindara Tilga Instrukcja

20 Września 2024
Jindara

Jindara Riverina Instrukcja

16 Września 2024
Jindara

Jindara Mallee Instrukcja

14 Września 2024
Jindara

Jindara Spectre Instrukcja

14 Września 2024
Jindara

Jindara Grange Instrukcja

13 Września 2024
Jindara

Jindara Gawler Instrukcja

11 Września 2024
Jindara

Jindara Sturt Instrukcja

11 Września 2024

Instrukcje Podgrzewacz

Najnowsze instrukcje dla Podgrzewacz