Instrukcja obsługi HQ -INV4000-24

HQ Niesklasyfikowane -INV4000-24

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla HQ -INV4000-24 (76 stron) w kategorii Niesklasyfikowane. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/76
MANUAL (p. 2)
DC to AC power inverter
MODE D’EMPLOI (p. 12)
Convertisseur de puissance CC vers CA
MANUALE (p. 23)
Inverter da DC a AC
BRUKSANVISNING (s. 44)
DC till AC strömomvandlare
MANUAL DE UTILIZARE (p. 54)
Invertor de tensiune CC în CA
BRUGERVEJLEDNING (p. 65)
DC til AC vekselretter
HASZNÁLATI ÚTMUTATÓ (o. 34.)
Egyenfeszültség-váltakozófeszültségű
teljesítnyinverter
YTTÖOHJE (s. 39)
DC - AC Invertteri
GEBRUIKSAANWIJZING (p. 18)
DC - AC stroomomvormer
ANLEITUNG (s. 7)
Wechselrichter
MANUAL DE USO (p. 29)
Conversor de corriente CC a CA
VOD K POUŽITÍ (s. 49)
Měn stejnosrného proudu na
střídavý proud
ΕΓΧΕΙΡΙΔΙΟ XPHΣHΣ (σελ. 59)
Inverter ισχύος από DC σε AC
VEILEDNING (p. 70)
Likestrøm til vekselstrøm-inverter
HQ-INV4000-12, HQ-INV4000-12F
HQ-INV4000-24, HQ-INV4000-24F
2
ENGLISH
12 V DC to 230 V AC Soft Start Power Inverter
24 V DC to 230 V AC Soft Start Power Inverter
4000 WATT CONTINUOUS OUTPUT POWER
SPECIFICATION
Specs. DC 12 V DC 24 V
Output power 4000 W continue 4000 W continue
8000 W surge output 8000 W surge output
Input voltage DC 10 ~ 16 V DC 20 ~ 30 V
Output voltage AC 230 V AC 230 V
Output waveform Modied sine wave Modied sine wave
Output frequency 50 or 60 Hz 50 or 60 Hz
Standby current < 1 A < 0.8 A
Efciency 85% ~ 90% 85% ~ 90%
High voltage input shutdown DC 16 V +/- 0.5 V DC 31 V +/- 0.8 V
Battery low alarm DC 10.5 V +/- 0.5 V DC 21 +/- 0.8 V
Battery low shutdown DC 10 +/- 0.5 V DC 20 +/- 0.8 V
Thermal protection 60 +/- 5°C 60 +/- 5°C
Cooling Temperature controlled fan Temperature controlled fan
Protection * Output short
* Input polarity reverse (by fuse)
* High DC input voltage
* Battery low alarm
* Battery low shutdown
* Overload
* Over temperature
Fuse 30 A * 18 pcs 15 A * 18 pcs
AC outlet Two Two
Size ( LxWxH ) 580x210x159 mm 580x210x159 mm
Weight 11.2 kg 11.2 kg
INSTALLATION
Mount the inverter horizontally or vertically on a at surface.
CAUTION!
Ensure these instructions are followed when installing the inverter:
1. Make sure the inverter stays dry.
2. The inverter should be installed in a cool place, ambient temperature between 0°C and 25°C.
3. To avoid re hazard and overheating, do not cover or obstruct the ventilation openings of the
inverter. Regularly check the ventilation openings as they collect dust and dirt. Also keep at
least 2.5 cm space around the inverter for air ow.
4. To avoid risk of re and explosion, please do not install the inverter close or next to ammable
substances or batteries.
5. Install the inverter out of reach of children.
3
OPERATION OUTPUT PANEL INSTRUCTIONS
POWER
indicator
ON/OFF
switch
OVER LOAD
indicator
VOLTS indicator AMPS indicator
Remote
ON/OFF
jack
OVER TEMP
indicator AC outlet
ON/OFF switch
For turning the inverter on/off.
Remote ON/OFF jack
Allows you to mount the inverter out of sight and turn ON or OFF with the remote control (included).
Battery voltage (VOLTS) indicator
The battery voltage indicator displays the voltage at the input terminal of the inverter.
Battery current (AMPS) indicator
The battery current indicator displays the current drawn from the battery by the inverter. Current should
be in the green zone for continuous operation. In the yellow zone the inverter will work for several
minutes, in the red zone the inverter protection will shut down the inverter.
POWER indicator
When connected to a battery and switched on, the power indicator is illuminated in green: ready for
use.
OVER TEMPERATURE indicator
The over temperature indicator is illuminated in yellow when the inverter is overheated. An alarm will
also sound and the inverter will shutdown.
Overheating is caused by operating the inverter with power levels above 4000 W continuous output. It
will also occur when it is installed somewhere where it cannot lose its heat properly. The inverter will
automatically restart when cooled down.
OVERLOAD indicator
The indicator is illuminated in red when an overload occurs. The problem can be solved by switching
the inverter off and reducing the load before switching it on again.
AUDIBLE ALARM
Alarm will sound in the case of:
a. Over temperature
b. Low battery (<10.5 V for 12 V inverter, <21 V for 24 V inverter)
c. Low battery shutdown (<10 V for 12 V inverter, <20 V for 24 V inverter)


Specyfikacje produktu

Marka: HQ
Kategoria: Niesklasyfikowane
Model: -INV4000-24

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z HQ -INV4000-24, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane HQ

HQ

HQ -INV2500\/12 Instrukcja

27 Września 2024
HQ

HQ P.SUP.EU27W Instrukcja

23 Września 2024
HQ

HQ -INV4000-24 Instrukcja

17 Września 2024
HQ

HQ P.SUP.EU1000 Instrukcja

11 Września 2024
HQ

HQ -INV300WU-12 Instrukcja

30 Sierpnia 2024
HQ

HQ W9-20196 Instrukcja

28 Sierpnia 2024
HQ

HQ -INV100U-24 Instrukcja

25 Sierpnia 2024
HQ

HQ P.SUP.SMP36- Instrukcja

25 Sierpnia 2024
HQ

HQ -INV300WU12F Instrukcja

25 Sierpnia 2024
HQ

HQ P.SUP.EU36W Instrukcja

19 Sierpnia 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024