K01- -02 0000638 EN
SMART APP SINEWAVE UPS SERIES
PR750RT2U PR750RTXL2U
PR1000RT2U PR1000RTXL2U
PR1500RT2U PR1500RTXL2U
PR2000RT2U PR2000RTXL2U
PR2200RT2U PR2200RTXL2U
PR3000RT2U PR3000RTXL2U
USER’S MANUAL
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at
www.cyberpowersystems.com/registration. Registration certifies your product's warranty, confirms your ownership in the event of a product
loss or theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.
The CyberPower Smart App Sinewave Uninterruptible Power Supply PR750RT2U/ PR1000RT2U/ PR1500RT2U/ PR2000RT2U/ PR2200RT2U/
PR3000RT2U/ PR750RTXL2U/ PR1000RTXL2U/ PR1500RTXL2U/ PR2000RTXL2U/ PR2200RTXL2U/ PR3000RTXL2U features 2430 Joules of surge
protection, provides battery backup during power outages and is Active PFC compatible for safeguarding mission-critical servers, telecom
equipment, VoIP and internetworking hardware that require seamless sine wave power. Its full Automatic Voltage Regulation (AVR) boost/buck
technology delivers a consistent and clean AC power, protecting connected equipment and preventing costly business interruptions. This UPS is
GreenPower UPS Bypass circuitry patented to save on energy costs by reducing energy consumption and heat buildup.
The UPS unit incorporates microprocessor-based full digital control and includes PowerPanel® Business software providing the user
unsurpassed flexibility and control. An optional SNMP/HTTP Remote Management adapter (RMCARD) supports remote management and
control of the machine through a standard web browser.
CyberPower GreenPower UPSTM Technology
CyberPowers patented GreenPower UPS with Bypass Technology are ENERGY STAR complainant ensuring lower power
consumption and energy costs compared to conventional UPS models. Even when utility power is normal, conventional
UPS models constantly pass power through a transformer. By contrast, under normal conditions the advanced circuitry
of a GreenPower UPS bypasses the transformer. As a result, the power efficiency is significantly increased while
decreasing waste heat, using less energy, and reducing energy costs.
When an abnormal power condition occurs, the GreenPower UPS automatically runs power through its transformer to
regulate voltage and provide “safe” power. Since utility power is normal over 88% of the time, the GreenPower UPS™
operates primarily in its efficient bypass mode.
The GreenPower UPS is also manufactured in accordance with the Restriction on Hazardous Substances (RoHS) directive making it one of the
most environmentally-friendly on the market today.
PRODUCT REGISTRATION
INTRODUCTIONS
AUTOMATIC VOLTAGE REGULATOR (AVR)
The incoming utility power may be damaging to important data and hardware, but with Automatic Voltage Regulation, the computer will not experience
damaging voltage levels. The AVR automatically increases low or decreases high voltage to a safe and consistent output voltag e.
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read
and follow all instructions thoroughly before and during the installation and operation of the product.
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection. DO NOT plug the UPS into an
outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS.
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive
contaminants. Please see specifications for acceptable temperature and humidity range.
CAUTION! For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. There are no serviceable parts inside,
except for the battery.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a
computer component.
CAUTION! When installing the equipment, ensure that the sum of the leakage current of the UPS and the connected equipment does not
exceed 3.5mA.
CAUTION! Do not unplug the unit from AC Power during operation, as this will invalidate the protective ground insulation.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in
accordance with the National Electric Code, ANSI/NFPA 70. (PR750RT2U/ PR1000RT2U/ PR1500RT2U/ PR2000RT2U/ PR750RTXL2U/
PR1000RTXL2U/ PR1500RTXL2U/ PR2000RTXL2U)
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 30 amperes maximum branch circuit overcurrent protection in
accordance with the National Electric Code, ANSI/NFPA 70. (PR2200RT2U/ PR3000RT / PR2200RTXL2U/ PR3000RTXL2U) 2U
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! DO NOT use in any circumstance that would affect operation or safety of
any life support equipment, with any medical applications, or patient care.
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near aquariums. Condensation from the
aquarium can come in contact with metal electrical contacts and cause the machine to short out.
CAUTION! DO NOT INSTALL THE UPS WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE!
CAUTION! DO NOT BLOCK OFF VENTILATION OPENINGS AROUND THE HOUSING!
CAUTION! DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any
transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit
to short out.
CAUTION! Dispose of or recycle the UPS after the end of its life, it should be in accordance with local regulations.
IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS)


Specyfikacje produktu

Marka: CyberPower
Kategoria: zasilacz UPS
Model: PR1500RTXL2U
Kolor produktu: Czarny
Typ wyświetlacza: LCD
Wysokość produktu: 86.5 mm
Szerokość produktu: 433 mm
Głębokość produktu: 412 mm
Waga produktu: 29300 g
Długość kabla: 2.54 m
Podręcznik użytkownika: Tak
Szerokość opakowania: 561.34 mm
Wysokość opakowania: 274.32 mm
Głębokość opakowania: 619.76 mm
Certyfikat środowiskowy (zrównoważonego rozwoju): RoHS, ENERGY STAR
Port USB: Tak
Napięcie operacyjne wejścia (maksymalne): 125 V
Pojemność baterii: 9 Ah
Technologia baterii: Ołowiany (VRLA)
Ilość portów Ethernet LAN (RJ-45): 2
Zakres temperatur (eksploatacja): 0 - 40 °C
Zakres wilgotności względnej: 0 - 95 %
Układ: Rackmount/Tower
Przewody: RS-232, USB cable
Waga wraz z opakowaniem: 36786.34 g
Rodzaj baterii: RB1290X4J
Częstotliwość danych wejściowych: 47/63 Hz
Diody LED: Tak
Zakres temperatur (przechowywanie): -15 - 45 °C
Dopuszczalna wilgotność względna: 0 - 95 %
Rodzaj chłodzenia: Aktywne
Port RS-232: 1
Liczba baterii: 4
Dopuszczalna wysokość podczas eksploatacji (n.p.m.): 0 - 3000 m
Bezpieczeństwo: UL1778, cUL107.1, FCC Class B
Napięcie baterii: 12 V
Dołączone śruby: Tak
Moc rzeczywista: 1500 W
Pojemność stelaża: 2U
Wbudowany wentylator: Tak
Maksymalna możliwa do konfiguracji moc: 1.5 kVA
Napięcie operacyjne wejścia (minimalne): 100 V
Napięcie operacyjne wyjścia (maksymalne): 100 V
Napięcie operacyjne wyjścia (minimalne): 125 V
Wartość znamionowa udaru energii: 2430 J
Słyszalny alarm: Tak
Ilość gniazd sieciowych: 8 x gniazdo sieciowe
Typy wyjść AC: NEMA 5–15R
Typowy czas podtrzymania przy połowie obciążenia: 17.9 min
Typowy czas podtrzymania przy pełnym obciążeniu: 6.5 min
Dopuszczalna wysokość (n.p.m.): 0 - 15000 m
Interfejs SCSI: RS-232
Ochrona przed nagłym wzrostem napięcia: Tak
Zestaw do montażu haków: Tak
Interfejs szeregowy: Tak
Przebieg falowy: Sinus
Automatyczna regulacja napięcia (AVR): Tak
Topologia UPS: Technologia line-interactive
Filtr EMI/RFI: Tak
Czas ładowania baterii (90%): 3 h
Akumulatory wymieniane podczas pracy: Tak
Tryby alarmu dźwiękowego: Alarm when on battery, Low battery alarm, Overload alarm
Typ PFC (Power Factor Correction) – korekcji współczynnika mocy: Aktywne
Czas transferu (Tryb Linii do Trybu Baterii): 4 ms