Instrukcja obsługi CyberPower OL6000E
CyberPower
zasilacz UPS
OL6000E
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower OL6000E (3 stron) w kategorii zasilacz UPS. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/3
® CyberPower Systems Inc. All Rights Reserved. www.cpsww.eu
Applications
- Home and Home Office
- Small Office
- Medium Business
- Corporate Data Center
- Networking, Servers & Workstations
- Industrial Equipment
Series Features
- Pure Sine Wave Output
- Online (Double Conversion) UPS Topology
- Rack/Tower Convertible Configurations
- EMI, RFI, Surge and Spike Protection
- Critical Load Outlets
- Phone/Fax/Modem/DSL/Network Protection
- Auto-Restart/Auto-Charge
- Emergency Power Off (EPO) Port
- Multifunction LCD Readout
- Rotatable LCD Indicator
- USB & Serial Connectivity Ports
- Extended Runtime (XL) Models
- Hot-Swappable Battery Packs
- SNMP/HTTP Remote Management Capability (Optional)
- PowerPanel® Business Edition Software
LCD Display
Dual Input Pure Sine Wave
SNMP /HTTP RM/T Form
Online Topology
Smart App Online Series
OL6000/8000/10000ERT3UD
OL6000/8000/10000E
The Best Quality Online Double
Conversion UPS That Offers The Highest
Level of Power Protection
Featuring Online Double Conversion UPS topology, the Online Series provides the
highest level of power protection and a guaranteed quality power supply to
demanding businesses who value versatility, flexibility, manageability and
performance. The numerous engineering excellences in the Online Series include an
Economy Mode Setting, Hot-Standby and a Detachable PDU. All to further enhance
its overall capability.
With its zero transfer time, the Online Series ensures continuous, consistent and
clean Pure Sine Wave power to all mission-critical equipment.
OLD0012EU-01
Pure Sine Wave Output
For applications that require Pure Sine Wave
power, CyberPower provides UPS models with
True Sine Wave output, also known as Pure
Sine Wave. They are designed for electronic
devices that have Power Factor Correction
(PFC) Power Supplies as well as for small AC
motors and other devices that need true sine-
wave power in order to function properly.
Online Double Conversion Topology
Online (Double Conversion) topology provides an extra layer of
insulation from power problems. This is achieved by continuously
operating off battery power and having zero transfer time during
power outages. Online topology also stabilizes output frequency
and voltage, and eliminates any line noise that may be apparent
in industrial settings or when operating off generator power.
PowerPanel® Business Edition Management S/W
AUTO-SHUTDOWN SOFTWARE
CyberPower PowerPanel®
Business Edition Management
Software, is compatible with
Windows7, Vista, XP, 2000 Pro.,
ME, 98, Windows Server 2008,
2003, Mac and Linux.
*Soware funcons may vary due to rmware version and/or hardware constraints.
® CyberPower Systems Inc. All Rights Reserved. www.cpsww.eu
Technical Specification
#All specicaons are subject to change without noce. © 2012 Cyber Power Systems. All Trademarks are the property of their ners. ow
Smart App Online Series
OL6000/8000/10000ERT3UD
OL6000/8000/10000E
Model OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD OL6000E OL8000E OL10000E
Conguraon
Capacity (VA / Watts) 6000 / 5400 8000 / 7200 10000 / 9000 6000 / 5400 8000 / 7200 10000 / 9000
Form Factor Rackmount / Tower (Converble) Tower
Topology Online (Double Conversion)
Energy-Saving Technology Yes
Input
Input Voltage Range 120 Vac - 139 Vac for 0~ 25% Load / 140 Vac- 159 Vac for 0~ 50% Load /
160 Vac - 179 Vac for 0~ 75% Load / 180 Vac - 280 Vac for 0~100% Load
Input Frequency Range 40 Hz - 70 Hz
Input Plug Type (1) Hard Wire 3-wire
Output
UPS Outlets (Numbers) (2) IEC C13, (1) IEC C19, (1) Hard Wire 3-wire (8) IEC C13, (2) IEC C19, (1) Hard Wire 3-wire
Output Frequency 50 Hz / 60 Hz (Auto-Sensing or Congurable) ± 0.25 Hz
Typical Transfer Time 0ms
Overload Protecon Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec
Baery Mode : 105~130% Load for 10 sec, 131~150% Load for 2 sec
Surge Protection and Filtering
Surge Protection IEC 61000-4-5 Level 3
DSL / Phone /FAX / Modem
Protecon RJ11 / RJ45 (One In / One Out)
Physical
Dimensions (H x W x D) (mm) –
Power Module 132 x 433 x 660
616 x 265 x 660 (Baery included)
Dimensions (H x W x D) (mm) -
Baery Module 132 x 433 x 660
Weight (kg) - Power Module 25 95 (Baery
included) 97 (Baery included)
Weight (kg) - Baery Module 76 78
Baery
Sealed Maintenance Free
Lead Acid Baery (20) 12V / 7.2AH (20) 12V / 9AH (20) 12V / 7.2AH (20) 12V / 9AH
Typical Recharge Time (Hours) 4 5 4 5
Hot-Swappable Yes
Runmes
Half-load / Full-load (mins) 15.8 / 5.3 22 / 8.5 15 / 5 15.8 / 5.3 22 / 8.5 15 / 5
Status Indicators
Indicators Power On, Line Mode, Baery Mode, Bypass Mode, Fault, Replace Baery
Audible Alarms Baery Mode, Battery Low, Overload, UPS Fault, Replace Baery
Mul-funcon LCD Readout Yes
Communicaon
PowerPanel® Business Edion Windows 7 / Vista / XP / 2000, Server 2008 / 2003, Linux
Management
Self Test Yes
Auto-Charge / Auto-Restart Yes
Auto-Overload Recovery Yes
Cold Start (DC Start) Yes
Connecvity Ports (1) Serial Port (RS232), (1) USB Port, (1) Remote Control Port, (1) Relay Out, (1) EPO, (1) Backfeed
SNMP/HTTP Capable Oponal
® CyberPower Systems Inc. All Rights Reserved. www.cpsww.eu
DISTRIBUTED BY: CyberPower’s
Manufacturing
Facilities are
ISO 9001:2000,
ISO 14000, and
QC080000
Approved
Rackmount Form Factor
Tower Form Factor
Model
BPE240V30ART3U
BPE240V50ART3U
BPE240V30A
BPE240V50A
Voltage
240VDC
Amperage
30A
50A
30A
50A
Physical
Dimensions (H x W x D) (mm)
132 x 433 x 660
600 x 265 x 660
Weight (kg)
76
78
135
139
Baery
Sealed Maintenance Free
Lead Acid Baery
(20) 12V / 7.2AH
(20) 12V / 9AH
(40) 12V / 7.2AH
(40) 12V / 9AH
Interface
PP45
Typical Recharge Time
4 Hours
5 Hours
4 Hours
5 Hours
Built-in Charger
Yes
Environment
Operang Temperature
32~104℉ (0~40℃)
Humidity
0~90% Non-Condensing
Battery
Smart App Online Series
OL6000/8000/10000ERT3UD
OL6000/8000/10000E
OL6000ERT3UD OL8000ERT3UD
OL10000ERT3UD
OL6000E
OL8000E
OL10000E
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | zasilacz UPS |
Model: | OL6000E |
Kolor produktu: | Czarny |
Wysokość produktu: | 600 mm |
Szerokość produktu: | 265 mm |
Głębokość produktu: | 660 mm |
Waga produktu: | 95 g |
Napięcie operacyjne wejścia (maksymalne): | 280 V |
Wydajność: | 95 % |
Ilość portów Ethernet LAN (RJ-45): | 1 |
Układ: | Mini Tower |
Liczba portów USB 2.0: | 1 |
Częstotliwość danych wejściowych: | 40/70 Hz |
Rodzaj chłodzenia: | Aktywne |
Port RS-232: | 1 |
Moc rzeczywista: | 5400 W |
Wbudowany wentylator: | Tak |
Szeregowe porty komunikacyjne: | 1 |
Maksymalna możliwa do konfiguracji moc: | 6 kVA |
Napięcie operacyjne wejścia (minimalne): | 120 V |
Napięcie operacyjne wyjścia (maksymalne): | - V |
Napięcie operacyjne wyjścia (minimalne): | - V |
Ilość gniazd sieciowych: | 11 x gniazdo sieciowe |
Typy wyjść AC: | C13 coupler, C19 coupler, Terminal |
Porty modemu rj-11: | 1 |
Typowy czas podtrzymania przy połowie obciążenia: | - min |
Typowy czas podtrzymania przy pełnym obciążeniu: | - min |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower OL6000E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje zasilacz UPS CyberPower
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
Instrukcje zasilacz UPS
- zasilacz UPS APC
- zasilacz UPS Tripp Lite
- zasilacz UPS FSP
- zasilacz UPS Emerson
- zasilacz UPS Adj
- zasilacz UPS PowerWalker
- zasilacz UPS Ditek
- zasilacz UPS Murr Elektronik
Najnowsze instrukcje dla zasilacz UPS
19 Września 2024
9 Lipca 2024
9 Lipca 2024
17 Czerwca 2024
17 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
30 Maja 2024