Strona 1/2
User’s Manual for
CyberShield
CS24C12V2-E
CyberShield Battery Backup Power Supplies are designed to provide a
local power solution for cable telephony, wireless local loop (WLL), and
fiber to the home (FTTH) broadband equipment.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack , install or operate this device
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the
battery. No user serviceable parts inside, except for the battery.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before
servicing the battery or installing a computer component.
ENCLOSURE INSTALLATION
Carefully follow these instructions during installation of this device:
1.) Carry out the installation in a safe area that is free of excessive dust and has adequate airflow.
2.) Screws must be appropriate for total weight of the Battery Backup Power Supply and the
mounting surface material .
3.) Do not operate the Battery Backup Power Supply where the temperature and humidity are
outside the specified limits. (Refer to specifications in this manual.)
BATTERY REPLACEMENT
This battery is hot-swappable. As long as utility power is on , you may leave the Battery Backup
Power Supply and connected equipment on while replacing a new battery.
Once the battery is disconnected, the connected equipment is not protected from power
outages.
Deliver spent batteries to a recycling facility or ship to the manufacturer in the
replacement battery packing material.
WARNING INDICATOR
OPERATION
Connect: Equipment and Power
Step1. Plug the Battery Backup Power Supply power cord into the utility power cord inlet
Step2. Plug the Battery Backup Power Supply power cord into the wall outlet.
The Battery Backup Power Supply battery charges when it is connected to utility power.
The battery charges fully during the first of normal operation. Do not expect 24 hours
full battery run capability during this initial charge period.
COLD START
The cold start feature is for applying power to the Battery Backup Power Supply and connected
equipment when the Battery Backup Power Supply is off and there is no utility power. Before using
the cold start feature, please make sure the battery is charged. To enable the cold start feature,
press the recessed cold start button with a small pointed object.
Battery Backup Power Supply is on utility power.
Battery Backup Power Supply is on battery power.
DC output power is provided by the battery or
utility power.
The battery is not connected or the battery needs to be
replaced.
Green
Yellow
Green
Red
Indicator Color Condition
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Unstrap strap from battery.
b. Slide battery off of the
shelf.
c. Disconnect battery cable
connector at the chassis end.
Step 3:
a. Use the enclosed installation template to
mark an installation location for the unit.
b. Mount the unit on the wall with 3 mounting
screws into the keyhole slots.
c. Tighten the screws to secure the units.
d. Connect the battery connector and replace
the battery back.
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Loosen the battery strap.
b. Disconnect battery cable connector
to remove battery.
c. Replace with new battery and
re-connect the battery connector.
Step 3:
a. Tighten the battery strip
b. Close the battery cover and
lock the case screw.
Front Panel
CS24C12V2-E
INTELLIGENT BACK-UP POWER
INTELLIGENT BACK-UP POWER
INTELLIGENT BACK-UP POWER
INTELLIGENT BACK-UP POWER
INTELLIGENT BACK-UP POWER
TM
TM
TM
TM
TM
AC
OUTPUT
BATTERY
Installation Suggestion:
To prevent the unit from intrusion of foreign matter, we suggest that the unit should be mounted on
a piece of wood which should then be attached to a wall underneath eaves.
Power Cable Selection:
A power cable (4.5m max.) being identified as 18AWG, "OUTDOOR" or "WATERPROOF"
should be selected while necessary.
COMMUNICATION SIGNALS
The communication signals of this unit are isolated from the internal circuitry via open collector opto-
coupled transistors. The connection “SIG RTN” (Signal Return) is a common return point for all
communication signals. In the typical application, the attached equipment digital ground connects to
Signal Return, and pull-up resistors turn the open collector signals into logic levels.
SPECIFICATION
LIMITED WARRANTY
CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited
Warranty. This Limited Warranty gives you specific rights, and you may have other rights, which vary from State to State or Province to Province.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to three years. This provision shall NOT create any Implied Warranty or
Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty. Your sole and exclusive remedies are those provided by this
Limited Warranty. This exclusion of other express warranties applies to written and oral express warranties. CyberPower excludes any liability for personal injury. CyberPower excludes any liability for direct,
indirect, special, incidental, or consequential damages, whether for damage to or loss of property, loss of profits, business interruption, information or data. This exclusion applies even though damage or loss
is caused by negligence or other fault. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES.
CyberPower does not sell the PRODUCT for use in high-risk activities. The PRODUCT is not designed or intended for use in hazardous environments requiring fail-safe performance, including the operation
of nuclear facilities, aircraft navigation or communication systems, air traffic control, weapons systems, life support or medical applications or for use in any circumstance in which the failure of the PRODUCT
could lead directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical or life support device (collectively, "High Risk Activities").
CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities. CyberPower does not authorize use of any PRODUCT in any High Risk activities.
ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT.
The Limited Warranty is governed by the laws of the United States and the State of Minnesota, without reference to conflict of law principles. The application of the United Nations Convention of Contracts for
the International Sale of Goods is expressly excluded
FCC NOTICE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1)Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an
experienced radio/TV technician for help.
CAUTION: Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits.
CAUTION: Any changes or modifications not expressly approved by Cyber Power could void the authority granted by the FCC to operate this equipment.
For more information, please contact:
CyberPower Systems ( USA ), Inc. 4241 12th Avenue East, Suite 400, Shakopee, MN55379 Phone: (952)403-9500 Fax: (952)403-0009 www.cpsww.com
CyberPower Systems ( EUROPE ), Inc. Flight Forum 3545, 5657DW Eindhoven, The Netherlands E-mail: sales@cyberpower-eu.com eu.cyberpowersystems.com
Input
Voltage Range
Frequency Range
Output
On Battery Output Voltage
Continuous Power Capability
Output Power Max
Efficiency (at 75% Max Load)
Battery
Battery Type
Numbers of Battery
Typical Recharge Time
Replaceable
Surge Protection and Filtering
Lightning / Surge Protection
Warning Diagnostics
Indicators
Management
Auto-Charge
Communication Interface
Physical
Maximum Dimensions (L*W*D)
Weight (kg)
Environment
Operating Temperature
Operating Humidity
Max Operating Elevation
Max Storage Elevation
Storage Temperature
100Vac - 240Vac (Universal Input)
50 - 60 Hz
12Vdc
24W
24W
> 75 %
Sealed, Maintenance Free Lead-Acid Battery
7.2AH / 12V x 1
18Hours
Yes
Yes
AC, Output, Battery
Yes
On Battery, Replace Battery, Battery Missing,
Low Battery
27.5cm x 20.4cm x 9.9cm
3.51
5oF - 122o
F (-15oC - 50oC)
0 - 95% noncondensing within enclosure
10,000ft (3,000m)
50,000ft (15,000m)
5oF - 122o
F (-15oC - 50oC)
12V
12V RTN
SIG RTN
ON BATTERY
REPLACE
BATTERY
BATTERY
MISSING
LOW BATTERY
+ Voltage output
- Voltage output
Signal return
Low when operating from utility line.
Open when operating from battery.
Low when battery is charged.
Open when battery fails the Self Test.
Low when battery is present.
Open when battery is missing.
Low when battery is near full charge capacity.
Open when operating from a battery with < 20%
capacity.
CS24C12V2-E Message
K01-2412H10-03
Model CS24C12V2-E
Back Panel
CS24C12V2-E
CS24C12V2-E
12V 24W
RISK OF ELECTRICAL SHOC K. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SER VICING TO QUALIFIED
SERVICE PERSONNEL. FOR USE IN A CONTROLLED ENVIRONMEN T.
REFER TO MANUAL FOR ENVIR ONMENTAL CONDITIONS.
E235457
FCC CLASS B VERIFIED
Cont ains sealed nonspillab le lead acid b attery .
Mus t be properly recy cled o r dispos ed.
INPUT:
CAUTION:
/ CS24C12V2-E
100-240V~ 50-60Hz ; 0.75A OUTPUT:
Made In C hina
R
68FG
LISTED
US
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | zasilacz UPS |
Model: | CyberShield CS24C12V2-E |
Kolor produktu: | Biały |
Wysokość produktu: | 203.2 mm |
Szerokość produktu: | 273.05 mm |
Głębokość produktu: | 95.25 mm |
Waga produktu: | 3492.66 g |
Długość kabla: | 3 m |
Certyfikat środowiskowy (zrównoważonego rozwoju): | RoHS |
Czas ładowania: | 18 h |
Technologia baterii: | Ołowiany (VRLA) |
Wydajność: | 76 % |
Zakres temperatur (eksploatacja): | 0 - 40 °C |
Zakres wilgotności względnej: | 0 - 95 % |
Waga wraz z opakowaniem: | 4535.9 g |
Częstotliwość danych wejściowych: | 50/60 Hz |
Diody LED: | Wymiana baterii |
Zakres temperatur (przechowywanie): | -15 - 45 °C |
Wymiary opakowania (SxGxW): | 355.6 x 120.65 x 355.6 mm |
Dopuszczalna wysokość podczas eksploatacji (n.p.m.): | 0 - 3000 m |
Moc rzeczywista: | 24 W |
Maksymalna możliwa do konfiguracji moc: | - kVA |
Ilość gniazd sieciowych: | - x gniazdo sieciowe |
Zimny start: | Tak |
Dopuszczalna wysokość (n.p.m.): | 0 - 15000 m |
Wartość nominalna napięcia wyjściowego: | 87-264 V |
Wartość nominalna napięcia wejściowego: | - V |
Akumulatory wymieniane podczas pracy: | Tak |
Tryby alarmu dźwiękowego: | Wymiana baterii |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CyberShield CS24C12V2-E, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje zasilacz UPS CyberPower
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
Instrukcje zasilacz UPS
- zasilacz UPS APC
- zasilacz UPS Tripp Lite
- zasilacz UPS FSP
- zasilacz UPS Emerson
- zasilacz UPS Adj
- zasilacz UPS PowerWalker
- zasilacz UPS Ditek
- zasilacz UPS Murr Elektronik
Najnowsze instrukcje dla zasilacz UPS
19 Września 2024
9 Lipca 2024
9 Lipca 2024
17 Czerwca 2024
17 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
30 Maja 2024