Instrukcja obsługi CyberPower CP1500PFCLCD
CyberPower
zasilacz UPS
CP1500PFCLCD
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla CyberPower CP1500PFCLCD (10 stron) w kategorii zasilacz UPS. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/10
PFC SINEWAVE UPS SERIES
CP1350PFCLCD/1500PFCLCD
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com
FEATURES
1. Power Switch
2. Power On Indicator
3. LCD Module Display
4. Down/Display Button
5. Up/Mute Button
6. Enter/Setup Button
7. USB charge ports
(Except for CP1350PFCLCD)
8. Battery and Surge Protected Outlets
9. Full-Time Surge Protection Outlets
10. Circuit Breaker
11. DB9/USB Ports to PC
12. Wiring Fault Indicator (red)
13. Communication Protection Ports (RJ45)
14. SNMP/HTTP Network Slot
(Except for CP1350PFCLCD)
15. Widely-Spaced Outlets Designed
for AC Adapters
Thank you for purchasing a CyberPower product. This UPS is designed to provide unsurpassed
power protection, operation, and performance during the lifetime of the product. Please take a
few minutes to register your product at: www.CyberPowerSystems.com/registration.
Registration certifies your product’s warranty, confirms your ownership in the event of a product
loss or theft, and entitles you to free technical support. Register your product now to receive the
benefits of CyberPower ownership.
CAUTION! To prevent the risk of fire or
electric shock, install in a temperature and
humidity controlled indoor area free of
conductive contaminants. (Please see
specifications for acceptable temperature
and humidity range.)
CAUTION! To reduce the risk of electric shock,
do not remove the cover except to service the
battery. Turn o and unplug the unit before
servicing the batteries. There are no user ser-
viceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be
energized by the battery even when the AC
input power is disconnected.
CAUTION! The UPS must be connected to an
AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is
not grounded. If you need to de-energize this
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the
unit and unplug it from the AC power source
before installing a computer component.
CAUTION! To reduce the risk of fire, connect
only to a circuit provided with 20 amperes
maximum branch circuit over current protec-
tion in accordance with the National Electric
Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as
defined in the Standard for the Protection of
Electronic Computer/Data Processing Equip-
ment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a fire.
The batteries may explode.
CAUTION! Do not open or mutilate batteries.
Released electrolyte is harmful to the skin and
eyes. It may be toxic.
DO NOT USE FOR MEDICAL
OR LIFE SUPPORT EQUIPMENT!
CyberPower Systems does not sell products
for life support or medical applications. DO
NOT use in any circumstance that would aect
operation and safety of life support equip-
ment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!
To reduce the risk of fire or electric shock, do
not use with or near an aquarium. Condensa-
tion from the aquarium can cause the unit to
short out.
DO NOT USE THE UPS
ON ANY TRANSPORTATION!
To reduce the risk of fire or electric shock, do
not use the unit on any transportation such
as airplanes or ships. The eect of shock or
vibration caused during transit and the damp
environment can cause the unit to short out.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to
unpack, install, or operate your UPS.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt.
The box should contain the following:
(a) UPS unit
(b) User’s manual
(c) USB A+B Type cable
(d) Function Setup Guide
PowerPanel® software is available on our
website. Please visit www.cyberpowersystems.
com and go to the Software Section for a free
download.
SUPPORTS Active PFC POWER SUPPLIES
This CyberPower UPS system supports High
Eciency power supplies with Active Power
Factor Correction (Active PFC). Active PFC is
used to improve the eciency of power delivery.
The current US Energy Star® Program Require-
ments for Computers (version 7.1) mandates
Active PFC for all power supplies over 100
watts. Additionally, programs such as 80 Plus®
are often used to identify high eciency power
supplies with Active PFC.
OVERVIEW
The CP1350PFCLCD/CP1500PFCLCD provides
complete power protection from utility power
that is not always consistent and features 1445
Joules of surge protection. All units provide long
lasting battery backup during power outages with
maintenance free batteries. The CP1350PFCLCD/
CP1500PFCLCD ensures consistent power to your
computer system and includes software that will
automatically save your open files and shutdown
your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CP1350PFCLCD/CP1500PFCLCD stabilizes
inconsistent utility power voltage to nominal
levels that are safe for equipment. Inconsistent
incoming utility power may be damaging to
important data files and hardware, but with
Automatic Voltage Regulation (AVR), damaging
voltage levels are corrected to safe levels.
AVR automatically increases low utility power
to a consistent and safe
110/120 volts. If incoming
utility voltage drops
below 90 volts, or exceeds
140 volts the units auto-
matically switch to battery
back-up power.
DETERMINE THE POWER REQUIREMENTS
OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into
the UPS does not exceed the UPS unit’s
rated capacity. If the rated capacities of the
unit are exceeded, an overload condition
may occur and cause the UPS unit to shut
down or the circuit breaker to trip.
2. There are many factors that can aect
the amount of power that your electronic
equipment will require. For optimal system
performance keep the load below 80% of
the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately
upon receipt. However, after receiving a
new UPS, to ensure the battery’s maximum
charge capacity, it is recommended that
you charge the battery for at least 8 hours.
Your UPS is equipped with an auto-charge
feature. When the UPS is plugged into an
AC outlet, the battery will automatically
charge whether the UPS is turned on or
turned o.
Note: This UPS is designed with a safety
feature to keep the system from being
turned on during shipment. The first time
you turn the UPS on, you will need to have
it connected to AC power or it will not
power up.
2. With the UPS unit turned o and unplugged,
connect your computer, monitor, and any
other peripherals requiring battery backup
into the battery power supplied outlets.
Plug the other peripheral equipment (eg.
printer, scanner, speakers, etc.) into the
full time surge protection outlets. DO NOT
plug a laser printer, paper shredder, copier,
space heater, vacuum cleaner, sump pump
or other large electrical device into the
“Battery and Surge Protected Outlets”.
The power demands of these devices will
overload and possibly damage the unit.
- continued
Specyfikacje produktu
Marka: | CyberPower |
Kategoria: | zasilacz UPS |
Model: | CP1500PFCLCD |
Kolor produktu: | Czarny |
Typ wyświetlacza: | LCD |
Długość kabla: | 1.52 m |
Certyfikat środowiskowy (zrównoważonego rozwoju): | RoHS |
Czas ładowania: | 8 h |
Certyfikaty: | UL1778, cUL 107.3, FCC DOC Class B |
Technologia baterii: | Ołowiany (VRLA) |
Ilość portów Ethernet LAN (RJ-45): | 1 |
Zakres temperatur (eksploatacja): | 0 - 40 °C |
Zakres wilgotności względnej: | 0 - 90 % |
Układ: | Tower |
Liczba portów USB 2.0: | 2 |
Rodzaj baterii: | 12V/8.5AH |
Częstotliwość danych wejściowych: | 60 Hz |
Diody LED: | Tak |
Dołączone oprogramowanie: | PowerPanel Personal Edition |
Waga (imperialna): | 24.7 funtów |
Moc rzeczywista: | 900 W |
Wymiary (SxGxW) (imperialne): | 3.9 x 14.2 x 10.4 " |
Szeregowe porty komunikacyjne: | 1 |
Maksymalna możliwa do konfiguracji moc: | 1.5 kVA |
Wartość znamionowa udaru energii: | 1030 J |
Słyszalny alarm: | Tak |
Ilość gniazd sieciowych: | 10 x gniazdo sieciowe |
Typy wyjść AC: | NEMA 5–15R |
Porty modemu rj-11: | 1 |
Typowy czas podtrzymania przy połowie obciążenia: | 11 min |
Typowy czas podtrzymania przy pełnym obciążeniu: | 2 min |
Wartość nominalna napięcia wyjściowego: | 120 V |
Wartość nominalna napięcia wejściowego: | 90-140 V |
Awaryjne wyłączenie zasilania: | Nie |
Topologia UPS: | Technologia line-interactive |
Akumulatory wymieniane podczas pracy: | Nie |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CP1500PFCLCD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje zasilacz UPS CyberPower
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
Instrukcje zasilacz UPS
- zasilacz UPS APC
- zasilacz UPS Tripp Lite
- zasilacz UPS FSP
- zasilacz UPS Emerson
- zasilacz UPS Adj
- zasilacz UPS PowerWalker
- zasilacz UPS Ditek
- zasilacz UPS Murr Elektronik
Najnowsze instrukcje dla zasilacz UPS
19 Września 2024
9 Lipca 2024
9 Lipca 2024
17 Czerwca 2024
17 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
2 Czerwca 2024
30 Maja 2024