Instrukcja obsługi AstralPool Viron QL540


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla AstralPool Viron QL540 (8 stron) w kategorii filtr do wody. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
QL
QL
QL
QLQL 420 / 540
420 / 540
420 / 540
420 / 540 420 / 540
CARTRIDGE FILTER
CARTRIDGE FILTER
CARTRIDGE FILTER
CARTRIDGE FILTER CARTRIDGE FILTER
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS
INST 371 VIRON QL Cartridge Filter V08- 20
2
IMPORTANT SAFETY PRECAUTIONS
IMPORTANT SAFETY PRECAUTIONS
IMPORTANT SAFETY PRECAUTIONS
IMPORTANT SAFETY PRECAUTIONS IMPORTANT SAFETY PRECAUTIONS
ATTENTIO
ATTENTIO
ATTENTIO
ATTENTIOATTENTION INSTALL
N INSTALL
N INSTALL
N INSTALLN INSTALLER
ER
ER
ERER: This guide contains important information about the installation, operation and safe use of this
product. This information should be given to the owner and/or operator of this equipment after installation or left on or
near the filter.
ATTENTIO
ATTENTIO
ATTENTIO
ATTENTIOATTENTION USER
N USER
N USER
N USERN USER: This manual contains important information that will help you in operating and maintaining this filter.
Please retain it for future reference.
- Before installing this product, read and follow all warning notices and instructions which are included
WARNING
WARNING
WARNING
WARNINGWARNING .
Failure to follow safety warning and instructions can result in severe injury, death or property damage.
OWNER INFORMATION AND SAFETY
OWNER INFORMATION AND SAFETY
OWNER INFORMATION AND SAFETY
OWNER INFORMATION AND SAFETY OWNER INFORMATION AND SAFETY
The VIRON QL Cartridge filter is designed and manufactured to provide many years of safe and reliable service when
installed, operated and maintained according to the information in this manual and the installation codes referred to in later
sections. Throughout the manual, safety warnings and cautions are identified by the symbol. Be sure to read and
comply with all of the warnings and cautions.
WARNING
WARNING
WARNING
WARNING WARNING: Do not operate the filter until you have read and understand clearly all the operating instructions
and warning messages for all equipment that is a part of the pool circulating system. The following instructions are intended
as a guide for initially operating the filter in a general pool installation, however each installation may have unique conditions
where the starting procedure could be different. Failure to follow all operating instructions and warning messages can result
in severe injury, death or property damage.
THIS FILT
THIS FILT
THIS FILT
THIS FILT THIS FILTER OPERAT
ER OPERAT
ER OPERAT
ER OPERATER OPERATES UNDER HI
ES UNDER HI
ES UNDER HI
ES UNDER HIES UNDER HIGH PRESSU
GH PRESSU
GH PRESSU
GH PRESSUGH PRESSURE.
RE.
RE.
RE.RE.
WARNING:
WARNING:
WARNING:
WARNING:WARNING:
When any part of the circulating system, (filter, pump, valves, clamp etc) are serviced, air can enter the system and become
pressurized. Pressurized air can cause the lid to be blown off, which can result in severe injury, death, or property damage.
To avoid this potential hazard, please follow these instructions.
1. Before repositioning valve(s) and before beginning the assembly, disassembly or adjustment of the clamp of the filter
or any other service of the circulating system, and shut any automatic controls to
TUR
TUR
TUR
TURTURN THE
N THE
N THE
N THE N THE PUMP OFF
PUMP OFF
PUMP OFF
PUMP OFFPUMP OFF OFF
OFF
OFF
OFFOFF
ensure the system is NOT inadvertently started during the servicing, Open the in the top of the
AI
AI
AI
AIAIR BLEED V
R BLEED V
R BLEED V
R BLEED VR BLEED VALVE
ALVE
ALVE
ALVEALVE
filter lid and wait until all pressure is relieved.
2. Whenever installing the filter clamp, follow the filter clamp installation instructions exactly.
3. Once service on the circulating system is complete,
F
F
F
FFOLLOW
OLLOW
OLLOW
OLLOW OLLOW THE RESTAR
THE RESTAR
THE RESTAR
THE RESTARTHE RESTART INSTRUCTIONS
T INSTRUCTIONS
T INSTRUCTIONS
T INSTRUCTIONST INSTRUCTIONS EXACTLY
EXACTLY
EXACTLY
EXACTLY EXACTLY
4. Maintain circulation system properly. Replace worn or damage parts immediately
5. Be sure that the filter is properly mounted and positioned according to instructions provided.
WARNING:
WARNING:
WARNING:
WARNING:WARNING:
Due to the potential risk that can be involved, it is recommended that the pressure test be kept to
the minimum time required by the local code. Do not allow people to work around the system when the circulation system
is under pressure test. Establish a barrier and post warning signs around the pressurized equipment. If the equipment is
located in a plant room, lock the access doors and post warning signs.
Never attempt to adjust any closures or lids or attempt to remove or tighten bolts on the system when pressurized. These
actions can result in a separation or failure of the system components. This instantaneous release of pressure can cause
components to be accelerated to high velocities and to travel great distances. These components could cause severe
personal injury or death if they were to strike a person.
Risk of e
Risk of e
Risk of e
Risk of e Risk of electrical s
lectrical s
lectrical s
lectrical slectrical shock or ele
hock or ele
hock or ele
hock or elehock or electrocution.
ctrocution.
ctrocution.
ctrocution. ctrocution.
WARNING:
WARNING:
WARNING:
WARNING:WARNING:
This pool filter must be installed by a qualified pool serviceman in accordance with the National Electrical Code (NEC) and
all applicable local codes and ordinances.
Always disconnect power to the pool equipment at the circuit breaker before servicing any of the equipment. Ensure that
the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the
pool equipment. Failure to do so could result in serious injury or death to service people, pool users or others due to
electric shock.
Position the filter and the air relief valve to safely direct water drainage and purged air or water. Water discharge from an
improperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage
property.
INST 371 VIRON QL Cartridge Filter V08- 20
3
WARNING
WARNING
WARNING
WARNINGWARNING:
:
:
: : To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
This filter is for use with permanently installed pools and may be used with hot tubs and spas if so
CAUTION
CAUTION
CAUTION
CAUTIONCAUTION:
:
:
: :
marked. Do not use with storable pools, A permanently installed pool is considered in or on the ground or in a building such
that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for
storage and reassembled to its original integrity.
GENER
GENER
GENER
GENERGENERAL INSTALLATI
AL INSTALLATI
AL INSTALLATI
AL INSTALLATIAL INSTALLATION INF
ON INF
ON INF
ON INFON INFORMATION
ORMATION
ORMATION
ORMATIONORMATION.
.
.
. .
The following information should be read carefully as it outlines the proper manner of care and operation of your filter
system. You can expect maximum efficiency and product life from you filtration system by following these instructions and
taking the necessary preventative maintenance.
*.Have a trained pool professional perform all pressure testing
* Do not connect the system to a high pressure or city water systems.
* Trapped air in the system can create a hazardous condition. MAKE SURE to purge all air from the system before operating
or testing of the equipment.
* DO NOT PRESSURE TEST WITH COMPRESSED AIR
* Check local codes for restrictions on backwash to waste piping, separation tank requirements.
* Piping must conform to local/state plumbing and sanitary codes
* Support piping independently to prevent strains on the filter or valve
* Fittings restrict flow, for best efficiency, use the fewest possible fittings
* A check valve installed between the filter inlet will prevent contaminants from draining back into the Pool.
* A check valve installed between the filter and heater will prevent hot water from backing up into the filter and deforming
the internal components.
* All wiring, grounding and bonding of associated equipment must meet local and/or National Electrical Code (NEC)
standards
GENERAL OVERVIEW
GENERAL OVERVIEW
GENERAL OVERVIEW
GENERAL OVERVIEW GENERAL OVERVIEW
The VIRON QL Cartridge filter features 4 easily accessible and removable filter cartridges. When water passes through these
cartridges, microscopic impurities like dirt, algae and some forms of bacteria are filtered out, giving you water that really
sparkles.
The 4 cartridges design greatly increases the filters internal surface area, meaning a much greater cleaning capacity for every
cycle without the need for a larger filter. After turning off and isolating the filter pump, cleaning is achieved by removing the
clamp band, lifing off the filter lid, removing the four filter elements and hosing off dirt and debris with a high pressure hose.
INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION INSTALLATION
Only a trained service person should install the VIRON QL rtridge filterCa .
Risk of ele
Risk of ele
Risk of ele
Risk of ele Risk of electrical s
ctrical s
ctrical s
ctrical sctrical shock or electroc
hock or electroc
hock or electroc
hock or electrochock or electrocution.
ution.
ution.
ution. ution.
WARNING
WARNING
WARNING
WARNING WARNING
Position the filter and allowing for the air/water bleed valve located in the lid to safely direct water drainage and purged air or
water. Water discharged from an improperly position filter can create an electrical hazard that can cause severe personal injury
as well as damage property.
THIS FILT
THIS FILT
THIS FILT
THIS FILT THIS FILTER OPERAT
ER OPERAT
ER OPERAT
ER OPERATER OPERATES UNDER HIG
ES UNDER HIG
ES UNDER HIG
ES UNDER HIGES UNDER HIGH PRESSU
H PRESSU
H PRESSU
H PRESSUH PRESSURE
RE
RE
RERE
WARNING
WARNING
WARNING
WARNING WARNING
Never subject the filter to pressure in excess of the maximum working pressure, even when conducting hydrostatic pressure
testing. Pressures above the maximum working PSI/Kpa pressures can cause the lid to be blown off and result in severe injury,
death or property damage
1. The filter should be mounted on a level concrete slab. Position the filter so that the instructions, warning and pressure
gauge are visible to the operator. It should also be positioned so that the piping connections, control valve and drain
port are convenient and accessible for servicing and winterizing.
2. Install electrical controls (timers, Chlorinators, power points) at least 6 feet from the filter. This will allow you enough
room to stand clear of the filter during start up.
3. Allow sufficient clearance around the filter to allow visual inspection of the clamp is correctly installed around the tank
flanges. Using a soft mallet tap the clamp to ensure uniform loading during the clamp tightening.
4. Allow enough space above the filter to remove the filter lid for cleaning and servicing. This distance should be a
minimum of 2 feet
5. The VIRON QL Cartridge filter has 1 inlet, 2 outlets and a drain port. Either inlet can be used (top outlet height for
other brands heaters, bottom outlet to suit HiNRG heaters. Whichever port you use the other will have to be plugged
with plug cap supplied with filter
6. Make all plumbing connections in accordance with local plumbing and building codes. Check local codes for restrictions
on backwash to waste piping, separation tank requirements. Allow minimum of 1 hour for glue to dry on pipe fittings
before pressuring up the system .
7. Filter plumbing connections are provided with an o-ring seal. To avoid damage to the o-rings, use only a silicone base
lubricant on the o-rings. Do not use a petroleum based lubricate as it will degrade the o-rings.


Specyfikacje produktu

Marka: AstralPool
Kategoria: filtr do wody
Model: Viron QL540

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AstralPool Viron QL540, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą