Instrukcja obsługi AFX Callie CALP05WHLNR3

AFX Lamp Callie CALP05WHLNR3

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla AFX Callie CALP05WHLNR3 (1 stron) w kategorii Lamp. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
E26 Bulb door Luminaires In
Ceiling Mount
120VAC / 60Hz
Page 1 of 1 R0 8061463
Part #: CALP05WH 3 LNR
Part #:
Limited Factory Warranty
AFX Inc. hereby warrants that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions
for a period of 5 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective xture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
View shown for
reference only.
Individual models
may vary.
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in potentially fatal
electric shock and/or property damage.
is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes. It
Do not handle any energizedxture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
This xture is designed for use in a 120 / 60Hz circuit. VAC
Make sure that the power source conforms to the requirements of the xture. (See labels on the xture housing).
To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a separate ground
wire (green) contact between this xture and the ground connection of your main power supply panel.
This xture is intended to be used for general indoor lighting in dry or damp locations.
Assembly Instructions
Step 1 Preparing for installation
A. at fuse or circuit breaker box before installing or servicing Disconnect electrical power
any part of this xture.
B. Carefully remove the xture from the carton, remove components from hardware kit.
C. Install the channel (1) to the junction box (not included) using two screws (2) to secure it.
D. Mark the locations of the four extra mounting holes on the ceiling. Take the channel (1)
down and punch a small hole into the ceiling at each location using a nail or an awl to see
if there is a wood joist. If there is a joist, use suitable wood screws (7) to mount the
channel (1). Where there is no joist to screw into, use a wall anchor (6) to mount pan
securely to the ceiling.
Step 2 Installing pendants
A. Install pendant to the cover plate (3) by pulling cord through the canopy strain relief (4).
Tighten the strain relief screw when the cord is at the desired height. Repeat for each
pendant.
Note: Each co rd is 108” long.
B. Once all pendants are their desired height, group all of the black pendant wires at
together along with an extra ying single black lead wire. This single lead will be used to
connect to the power source in Step 3. Secure with wire nut (provided).
C. Repeat Step 2B for all white pendant wires.
Wiring All wiring must take place inside junction box (not included)
Caution: Make sure power is o at fuse or circuit breaker box. Check power wires for
damage or scrapes. Use wire suitable for at least 90°C (194°F). Most dwellings Note:
built before 1985 have supply wire rated to 60°C. Consult a qualied electrician to ensure
correct branch circuit conductor before installing.
Step 3 Wiring xture
A. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
B. Connect the green wire from the xture to the supply source ground wire.
C. Connect the black wire from the pendants to the black (L) wire from supply power source.
D. Connect the white wire from the pendants to the white (N) wire from supply power source.
E. Pull on each wire lead to make sure connections are secure. Make Do not mix wires.
certain no bare wires are exposed outside of wire connectors. Tuck all connections neatly
into the junction box.
Step 4 Installing cover pla te
A. Align the mounting holes on the xture plate with the two screws on the xture channel (1)
and use two nials (5) to secure it.
Step 5 Installing diusers
A. Slide glass diuser (9) over the socket assembly (8) and use the fastener 0 to secure (1 )
the diuser in place. Note: Do not over tighten as it may cause chipping of the glass.
Step 6 Lamping
A. Install medium base bulb (E26, 60W max not included) into each socket and turn clockwise until
secured.
Step 7 Restore power at fuse or circuit breaker box

Specyfikacje produktu

Marka: AFX
Kategoria: Lamp
Model: Callie CALP05WHLNR3

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z AFX Callie CALP05WHLNR3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Lamp AFX

Instrukcje Lamp

Najnowsze instrukcje dla Lamp