Instrukcja obsługi Zoeller 131


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Zoeller 131 (8 stron) w kategorii Przepych. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/8
© Copyright 2013 Zoeller Co. All rights reserved.
DRAIN PUMP SYSTEMS
MODELS 104*, 105, 110, 115, 120, 131
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
P/N 017583
SECTION: 6.10.045
FM2336
1113
Supersedes
0612
Notice to Installer: Instructions must remain with installation.
MODEL: ______________________
DATE CODE: __________________
DATE INSTALLED: _____________
1. Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. remove the test DO NOT
plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specic details regarding installation and use. These materials should be retained for future reference.
1. To reduce the risk of electrical shock, a properly grounded receptacle of grounding
type must be installed and protected by a ground fault circuit interrupter (GFCI)
and in accordance with National Electrical Code and local codes.
(SEE WARNING BELOW)
2. Make certain that the receptacle is within the reach of the pump’s power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that
are too long or too light do not deliver sufcient voltage to the pump motor.
But more important, they could present a safety hazard if the insulation were
to become damaged or the connection end were to fall into the sump.
3. Testing for Ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly connected
to your outlet. If they are not, call a qualied electrician.
4. For Added Safety. Pump must be connected to a 3-prong grounded outlet
interrupter device (ground fault circuit interrupter).
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied
with a 3-prong grounded plug to help protect you against the possibility of
electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE
GROUND PIN. To reduce the risk of electrical shock, a properly grounded
receptacle of grounding type must be installed and protected by a ground
fault circuit interrupter (GFCI) in accordance with national electrical code and
local codes.
6. Installation and checking of electrical circuits and hardware should only be
performed by a qualied licensed electrician.
7. Risk of electric shock - These pumps have not been investigated for use in
swimming pool areas.
8. According to the state of California (Prop 65), this product contains chemicals
known to the state of California to cause cancer and birth defects or other
reproductive harm.
1. Check to be sure your power source is adequate for handling the voltage
requirements of the motor, as indicated on the pump or basin plate.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the National Electrical Code for the current shown on the pump
name plate.
3. All plumbing (discharge and vent lines) must be installed to meet local codes.
Unit must be vented. DO NOT USE AN AUTOMATIC PLUMBING VENT
DEVICE SIMILAR TO A "PRO-VENT". Some states require this product to
be installed by a licensed plumber.
4. Repair and service should be performed by Zoeller Pump Company Authorized
Service Station only.
5. CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING
OF PUMP. Check valve must be purchased separately on model 104 only.
6. Dewatering pumps are not designed or intended for handling raw sewage.
7. Maximum operating temperature for 105-131 Drain Pumps must not exceed
130°F (54°C). 104 Drain Pumps are not to exceed 110°F (43°C).
8. For health reasons, do not unplug, turn off, or disable pump and use pump
tank system as a way to ll up a sink or laundry tray, etc.
9. Unit is designed for above ground installation only.
SEE BELOW FOR LIST OF WARNINGS
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
* MODEL 104 IS NOT
IAPMO APPROVED.
UPC
®
C
COMPLIES WITH ASME A112.3.4
and CSA B45.9
REFER TO WARRANTY ON PAGE 2.
Pumps with the UL” mark and pumps with the USmark are tested to
UL Standard UL778. CSA Certified pumps are certified to CSA Standard
C22.2 No. 108.
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
®
Your Peace of Mind is Our Top Priority
®
2
© Copyright 2013 Zoeller Co. All rights reserved.
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used and
maintained, for a period of one year from date of purchase by the end user, or
18 months from date of original manufacture of the product, whichever comes
rst. Parts that fail within the warranty period, one year from date of purchase
by the end user, or 18 months from the date of original manufacture of the
product, whichever comes rst, that inspections determine to be defective
in material or workmanship, will be repaired, replaced or remanufactured
at Manufacturer's option, provided however, that by so doing we will not be
obligated to replace an entire assembly, the entire mechanism or the complete
unit. No allowance will be made for shipping charges, damages, labor or
other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or act of
God; that has not been installed, operated or maintained in accordance with
Manufacturer's installation instructions; that has been exposed to outside
substances including but not limited to the following: sand, gravel, cement,
mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents,
etc.), or other abrasive or corrosive substances, wash towels or feminine
sanitary products, etc. in all pumping applications. The warranty set out in
the paragraph above is in lieu of all other warranties expressed or implied;
and we do not authorize any representative or other person to assume for us
any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention: Customer Support Department to obtain any needed repair or
replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH
OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF
MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE
EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty,
so the above limitation may not apply to you. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specic legal rights and you may also have other
rights which vary from state to state.
Limited Warranty
ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump - making
sure you are not standing in water and wearing insulated protective sole shoes. Under ooded conditions, contact your local electric company or a
qualied licensed electrician for disconnecting electrical service prior to pump removal.
Submersible pumps can become pressurized under normal operating conditions allow hours after disconnecting before attempting service.
CONDITION
A. Pump will not start or run.
B. Motor overheats and trips overload
or blows fuse.
C. Pump starts and stops too often.
D. Pump will not shut off.
E. Pump operates but delivers little
or no water.
F. Drop in head and/or capacity after
a period of use.
G. Iftankorttingsleak.
If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must
be by a Zoeller Authorized Service Station.
Service Checklist
COMMON CAUSES
Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically,
defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective,
damaged, or out of adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defective
capacitor or relay, motor shorted.
Float too tight on rod, check valve stuck, or none installed in long distance line, overload open, switch
defective.
Debris underoat assembly, oat or oat rod bound by basin sides or other, switch defective, damaged or out of adjustment.
Check strainer housing, discharge pipe, or if check valve is used, the vent hole must be clear. Discharge head
exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water
containing air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly
deteriorate impeller and pump housing. Check line. Remove base and inspect.
Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do not over
tighten ttings or screws.
3
© Copyright 2013 Zoeller Co. All rights reserved.
1. Read all instructions before beginning installation.
2. Be certain that basin is on a rm level surface.
3. Do not use an automatic plumbing vent device.
4. Do not over-torque lid attachment screws.
5. Always use a check valve on the discharge line.
6. Test operation of pump per STEP 6.
Ten Helpful Hints For Easy Installation
Performance Characteristics
7. Always provide some means to disconnect basin from plumbing for
maintenance purposes.
8. Run unit at least once a month to verify proper operation.
9. The model number and date code can be found on the lid warning label.
10. Plug pump into a properly grounded GFCI receptacle.
009898
Meters
20 6.1
Shut-off Head:
15 4.6
10 3.0
5 1.5
Feet
MODELS
Liters
273
231
170
19.25 ft. (5.9m)
--
19
34
43
--
72
9525
23 ft. (7.0m)
45
129
163
61
72
Gal.
104/132
Liters Gal. Liters Gal.
131
105/110
115/120
18 ft. (5.5m)
38
14
30
144
53
114
-- --
2010
0
GALLONS
LITERS
0
5
504030
80 160
FLOW PER MINUTE
105/110/
8060 70
240
131
PUMP PERFORMANCE CURVE
104/105/110/115/120/131/132
4
TOTAL DYNAMIC HEAD
2
10
15
620
FEET
METERS
25
115/120
104/132
1. DO read all installation material included with the pump.
2. DO inspect unit for any visible damage caused by shipping. Contact
dealer if unit appears to be damaged.
3. DO clean all debris from the basin and pump.
4. DO always disconnect pump from power source before handling.
DO always connect to a separately protected and properly grounded
ground fault protected circuit. DO NOT ever cut, splice or damage
power cord. DO NOT carry or lift pump by its power cord. DO NOT use
an extension cord.
Do’s And Don't’s For Installing A Unit
5. DO NOT use a discharge pipe smaller than the pump discharge size.
6. DO test pump immediately after installation to be sure that the system
is working properly.
7. DO review all applicable local and national codes and verify that the
installation conforms to each of them.
8. DO NOT install unit in the ground.


Specyfikacje produktu

Marka: Zoeller
Kategoria: Przepych
Model: 131

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Zoeller 131, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Przepych Zoeller

Zoeller

Zoeller 131 Instrukcja

27 Marca 2025
Zoeller

Zoeller M282 Instrukcja

27 Marca 2025
Zoeller

Zoeller M98 Instrukcja

25 Września 2024
Zoeller

Zoeller M267 Instrukcja

25 Września 2024

Instrukcje Przepych

Najnowsze instrukcje dla Przepych