ZCF CARTRIDGE FILTER
INSTALLATION AND
OPERATING INSTRUCTIO NS
Bolero ND Cleaner
ZX
H0656600 REVA
2
H0656600 REVA
3
INTRODUCTION
Congratulations on the purchase of your ZODIAC Z series cartridge lter. CF
The Z series lters are made to last by utilising the best quality materials available. The tank is made from high CF
quality ABS plastics, capable of withstanding the harshest of conditions.
INSTALLATION OF Z SERIES CF
1. Ensure cartridge lter is located on a clean, stable and level base.
2. The Z series lter has three inlet ports (from pump) and one outlet port (to pool/spa). Glue one of the 50mm slip CF
tails supplied into one of the inlets and second slip tail supplied into the outlet of the lter that suits the plumbing
conguration.
3. Glue in the supplied blanking cap and drain plug cap into the two remaining inlets. Allow a minimum of one hour
for glue to dry before subjecting lter to system pressures.
4. Glue water connection pipes from pump and pool return to 50mm tails supplied. (Ensure locking nut is placed on
pipe before gluing on tails.
5. Apply Teon tape (not included) to the pressure gauge and screw into lid where indicated.
START UP INSTRUCTIONS
1. Before starting your Z lter, make sure the cartridge is in the lter and the lid and lock ring are in place and up CF
tightened.
2. Open the suction and return line valves (when tted).
3. Start pump and open the air release valve on the filter lid 2 to 3 turns air will begin to be forced from the tank.
Once water begins to flow from the valve, tighten to close. Check there is a good ow of water back in the pool. to
4. Clean the cartridge when the ow to the pool reduces or the pressure gauge increases by 15 20 kPa.
PUMP PRIMING
1. With the pump OFF, remove the lid from the pump strainer and ll with water to the top of the lit pot.
2. Replace and tighten lid on pump.
3. If valve has been installed on the pump suction line, close before lling strainer. Open again after lid has been
securely fastened in place. Any valves on the return lines should be open. The pump should not need to be re-
primed unless the pump has been drained for servicing, or winterizing (refer to complete pump operations manual
provided with pump).
TO CLEAN FILTER CARTRIDGE ON ZCF SERIES
1. Stop pump-close valves on the suction and return lines.
2. Open the air bleed valve on the lid.
3. Proceed to loosen locking ring on lter. As you turn the locking ring, the lid of the lter will be lifted out of the
body. Once lid is free of the body, lift lid and locking ring together and place in a clean location. You can now
remove the cartridge.
4. Clean the cartridge by soaking it in a mild solution of chlorine and warm water for 15 minutes and then hose o
with water. Alternatively, special formulated element cleaning solutions can be purchased from most pool
professionals. (Note: do not use high powered water jets to clean this may cause damage to the element)
5. Replace the cartridge; ensure correct location on the bottom spigot.
6. Insert the top locating spigot into the element.
7. Clean the lid, locking ring and These should be rinsed with clean water to ensure not grit or grime has lid ‘o’ ring.
deposited into the threads. Replace the lid and locking ring onto the top of the lter tank, ensuring correct
alignment with the locating spigot..
8. Commence tightening the lid lock ring the lid will begin to be pulled down into the lter tank. Continue to tighten
the lock ring until safety catch locks into place. DO NOT OVERTIGHTEN LOCKING RING AS THIS MAY CAUSE
THE FILTER TO LEAK..
9. Open the valves start the pump.
NEVER LOOSEN THE LOCK RING WHEN THE PUMP IS WORKING


Specyfikacje produktu

Marka: Zodiac
Kategoria: Filtr wody
Model: ZCF100

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Zodiac ZCF100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Filtr wody Zodiac

Zodiac

Zodiac TP500 Instrukcja

15 Września 2024
Zodiac

Zodiac ZCF150 Instrukcja

15 Września 2024
Zodiac

Zodiac ZT800 Instrukcja

15 Września 2024
Zodiac

Zodiac ZT650 Instrukcja

15 Września 2024
Zodiac

Zodiac ZCF75 Instrukcja

14 Września 2024
Zodiac

Zodiac ZT650B Instrukcja

13 Września 2024
Zodiac

Zodiac ZT700B Instrukcja

10 Września 2024
Zodiac

Zodiac ZCF100 Instrukcja

8 Września 2024
Zodiac

Zodiac ZT500 Instrukcja

7 Września 2024

Instrukcje Filtr wody

Najnowsze instrukcje dla Filtr wody

Laica

Laica J35-AD Instrukcja

15 Października 2024
Laica

Laica J35-EB Instrukcja

15 Października 2024
Laica

Laica J11-AB Instrukcja

15 Października 2024
Laica

Laica J51-BC Instrukcja

15 Października 2024
GE

GE GX1S15C Instrukcja

13 Października 2024
Grohe

Grohe Red Instrukcja

11 Października 2024
Fluval

Fluval AquaClear AC30 Instrukcja

9 Października 2024
Fluval

Fluval AquaClear AC50 Instrukcja

9 Października 2024
Fluval

Fluval AquaClear AC20 Instrukcja

9 Października 2024
Fluval

Fluval AquaClear AC70 Instrukcja

9 Października 2024