Instrukcja obsługi Yale EF-KIT2


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Yale EF-KIT2 (28 stron) w kategorii system alarmowy. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/28
Installation · Programming · Operating
Keep this manual safe for reference and future maintenance
Telecommunicating
Alarm (EF-KIT2)
Introduction Contents
Thank you for choosing the Yale Telecommunicating Alarm
System. This simple to install system has been designed
with the user in mind.
All the components are self contained and no connections
are needed between the units. There is no need to
damage the home decor, lift carpets or run cables.
You can install up to 30 devices in this system. As well
as extra Door/Window Contacts, PIR’s and Smoke
Detectors, you can add Key Fobs and Key Pads for added
control convenience.
There is no need to wire into the mains supply or seek
the services of a qualified electrician. The Control Panel is
powered by a plug top supply and all other components
are powered by battery (all batteries included).
Regular testing and battery changes (when notified by the
system) will ensure reliability and peace of mind.
All components are ‘tamper’ protected. Any unauthorised
tampering with these items will result in an alarm. This
feature can be turned off by the user when a battery
change is required.
Display extreme caution when using ladders or steps,
please follow manufacturer’s instructions.
Be careful when using hand and power tools and follow
the manufacturer’s guidelines when using them. Take care
that the correct tools are used. Wear goggles or protective
clothing where required.
The external Siren is extremely loud, please ensure you
replace the cover and retreat to a safe distance before
testing.
The dialling facilities must only be used with persons who
have consented to being contacted by the system.
The system is not to be used to make 999 emergency
calls directly. Yale do not hold responsibility for any actions
taken by emergency services for incorrect use of the
dialling facility.
Special Notes on Compatibility:
This alarm system is NOT compatible with HSA6000
series and HSA3000 series accessories. Please note the
prefix “ ” in the front of the part number to indicate EF-
compatibility (note: not compatible with accessories that
carry an ” prefix). SR-
Information and illustrations are subject to change within this
document. Yale reserves the right to alter the specification and
product design at anytime without notice. Yale® is a registered
trademark. © 2016 ASSA ABLOY. All rights reserved.
Contents
1. Location planning 2
2. Un-pack all the parts 4
3. First Time Easy Install 6
4. Mounting alarm devices 8
5. Control Panel Menu System in Detail 11
6. Using the System 17
7. Adding and using Accessories 20
8. Changing the batteries 22
9. Troubleshooting 24
10. Sensor response table 26
11. Specifications 27
Recommended Installation Sequence
We recommend you follow the simple install
sequence, headings numbered 1-6.
smart
Living
Issue No: 1A
The 2 year guarantee for this Yale
Telecommunicating Alarm Kit is active
from the date of purchase (A copy
of this guarantee is available on our
website). Please register online within 12
months of purchase at www.yale.co.uk/
registeryourproduct
2
For more information on this product and Yale Smart
Living Range visit www.yale.co.uk/smart-living
Consumer Support: info@yale.co.uk
2
aleY
1 2 3
654
7 8 9
0
aleY
Location planning
Home and Away Mode Planning
The Home Arming mode allows the premises to be
part armed so that no one can get inside without
warning the occupier, yet the person already inside
the house can move freely without triggering the
alarm. For example the downstairs of a house can
be armed while upstairs can be disarmed allowing
the user to go to bed without causing an alarm.
If this feature is to be used, then it should be
planned now, before installation.
Decide what areas can be occupied when in Home
Arming mode, the sensors for these areas should be
ignored using the “Home-Arm set” option (see page
11); and the sensors activated on the path to access
the Control Panel should be to be set to either Entry
or Away Entry as explained in Chapter 5.
Operating Range
All devices must be within 30 metres of the Control
Panel and must not be mounted on or near large
metal objects. Avoid obvious sources of electrical
interference such as fridges and microwave ovens.
Tamper Switches
When mounting devices ensure that any tamper
switches close fully. On uneven surfaces it may be
necessary to place packing behind the switch for
reliable operation.
Extend The System
Extend the system in the future to increase your
security or as your needs change.
For example, add extra PIR Motion Detectors and
extra Door/Window Contacts.
Choosing Location
To minimise interference, avoid locating devices
close to metal framework, glass, electrical
appliances (especially wireless devices) and electric
cables.
Please note that the present of high density material
(metal, glass etc) in the transmission path will
significantly reduce the wireless transmission range.
1
Work out the best places to locate the devices for maximum protection. Having chosen the
locations do not mount at this stage.
Key Pad
A second Key Pad is ideal for use in bedrooms
or at the top of a stairwell so the ground floor can
be armed when going to bed for the night, or at a
side or back door for alternative entry point.
• Mount at chest height for ease of use
• Designed for indoor use only
• Key Pad should be accessible from a protected
entry/exit point
• Ensure that the Key Pad is not visible from the
outside of the premises.
Panic Button
The Panic Button provides extra protection for
you and your family. When help is needed the
button can activate your alarm immediately - even
when the system is disarmed.
• Mount on flat wall surface
• Designed for indoor use only
• Out of reach of children
• Hidden from view while easily accessible.
3
Y ale
aleY
Key Fob
Can be used inside or outside the property and
can be kept on your keyring.
Smoke Detector
• Mount in the middle of the ceiling at the top of
a stairwell, or on the centre of hallway ceilings
where smoke would most likely be detected.
• Do not mount in corners or above cooking
appliances and heaters.
• Install additional detectors if there are closed
doors preventing smoke from reaching
detectors.
Door/Window Contact
Select a door that will be the main point of entry
and exit, usually your front door.
• Mount as high as possible
• Do not aim a PIR at this door or Window
Text Display
PIR Motion Detector
• Mount in a position such that an intruder would
normally move across the PIRs field of view.
• Height should be between 1.9 and 2 metres
above floor level.
• Location in a corner will ensure wider room
coverage.
• Do not mount the PIR where its field of view will
be obstructed e.g. by curtains, ornaments etc.
• Do not point directly at sources of heat e.g. fires
or boilers, and do not position directly above
radiators.
• Avoid mounting the PIR directly facing a
Window.
• Do not point the PIR at a door protected by a
Door/Window Contact.
Control Panel
• Ensure it is hidden from view while accessible.
• Access to mains socket and telephone point.
External Siren
Choose a position on an external wall where the
Siren would be most prominent. Mount as high
as possible, out of easy reach.


Specyfikacje produktu

Marka: Yale
Kategoria: system alarmowy
Model: EF-KIT2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Yale EF-KIT2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje system alarmowy Yale

Instrukcje system alarmowy

Najnowsze instrukcje dla system alarmowy