Strona 1/7
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01741 01 2411
01741
BY-ALARM PLUS
By-alarm Plus passive infrared detector for the protection of building exteriors, independent 12-metre curtain-effect detection on each side (left
and right), with anti-masking, PET immune, IP55, 2 NO and NC 28 VDC 0.1 A relay outputs per output, 9.5-18 VDC 34 mA 12 V power supply,
surface mounting, for outdoor use.
The device features an anti-masking function and four PIR, i.e. two on each side. They can be set independently from one another for total control of the left and right detection zones. The
detection range, sensitivity and alarm output can be configured completely independently for the left and right side. The detection distance can be set to 2.5 m, 3.5 m, 6 m, 8.5 m and 12
metres on each side. Sensitivity can be set to between low and extremely high, with the possibility of detecting only a temperature difference of 1 degree °C.
CHARACTERISTICS
Power supply: 9.5-18 VDC
Absorption: 34 mA a 12 VDC
Detection mode: passive infrared
Cover: 24 m and 4 zones on two independent sides:
- 12 m per side
- 2 zones on each side, 180° narrow
Detection range from the wall (selectable):
- 0° near the wall
- 3° away from the wall
Detection length limit: from 2.5 to 12 m (5 levels: 2.5-3.5-6-8.5-12)
Alarm output (R): 28 VDC 0.1 A (max); [Individual: Right or General], [NO or NC] selectable
Alarm output (L): 28 VDC 0.1 A (max); [Individual: Left or General], [NO or NC] selectable
Fault output: NC 28 VDC 0.1 A (max)
Tamper output: NC 28 VDC 0.1 A (max), open when the front cover or the fixing base are removed
Detectable speed: from 0.3 to 2 m/s
Sensitivity individually settable for each side:
- Normal, 2 °C (at 0.6 m/s)
- High, 1 °C at 0.6 m/s
Initialisation time: approximately 60 s
Alarm duration: 2 1 s±
Operating temperature: - 30..+ 60 °C
Ambient humidity: 95%
Protection degree: IP55
LED SIGNALLING
Red side LED:
permanently lit -> Alarm
flashing -> Masking detection and initialisation phase
INSTALLATION RULES
Installation must be carried out by qualified persons in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are
installed.
Install the detector in a place where no cause for false alarms is present, such as:
- sunlight and reflections;
- heat sources;
- moving objects or objects which the wind may move.
The ideal installation height is between 0.8 to 1.2 m with the base of the detector always parallel with the wall.
The detector can be mounted using mounting frame art. 01741.S which increases its thickness in the event of specific installation requirements.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - User information
The crossed out bin symbol indicates that the product must be sent to separate collection facilities for recovery and recycling, in compliance with the national laws of EU Countries that implement the WEEE Directive. The objective is to prevent
any harmful effects on the environment and on human health by ensuring that products are disposed of correctly, avoiding illegal disposal sanctioned by law.
To dispose of the product correctly, please check local dispositions in your country.
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01741 01 2411
1
ON
2345678
MOUNT I
UP
2.7 t o
POLE
THE DETECTOR
INSTALLATION
1 2 3 4
5 6 78
Set the dip switches, make the con-
nections and close the detector.
Cable protection foam
Main unit Fixing base
Front cover
Dip
switches
1
ON
234
1
ON
28
MOUNT I
UP
2.7 to
POLE
1
ON
2345 6 7 8
AWAY WALL
2345 678
1
ON
234567
8
Foam
Sponge
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01741 01 2411
ASSEMBLY
MOUNTING
2.7 to 4.0 ft
MOU NT I
UP
2.7 to
POLE
MOUNTI
UP
2.7 to
POLE
MOUNTI
UP
2.7 to
POLE
Mounting on electrical junction box
Conductor installation on mounting frame art. 01741.SPole mounting
Mounting with optional components:
Mounting height
0.8-1.2 m (1 m is recommended)
Metal cable tie
=<23 mm in width
83.5 mm centre distance
WARNINGS
NO
OK
1
O N
234 56 7 8
0,8 - 1,2 m
Parallel


Specyfikacje produktu

Marka: Vimar
Kategoria: Nie skategoryzowane
Model: 01741

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Vimar 01741, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Nie skategoryzowane Vimar

Vimar

Vimar 01467 Instrukcja

2 Kwietnia 2025
Vimar

Vimar 01741 Instrukcja

2 Kwietnia 2025
Vimar

Vimar 01970 Instrukcja

2 Kwietnia 2025
Vimar

Vimar 01743 Instrukcja

2 Kwietnia 2025
Vimar

Vimar 32101 Instrukcja

2 Kwietnia 2025
Vimar

Vimar EZS25 Instrukcja

2 Kwietnia 2025
Vimar

Vimar EZP20 Instrukcja

2 Kwietnia 2025
Vimar

Vimar R288 Instrukcja

2 Kwietnia 2025
Vimar

Vimar EZS20 Instrukcja

2 Kwietnia 2025
Vimar

Vimar RS05 Instrukcja

1 Kwietnia 2025

Instrukcje Nie skategoryzowane

Najnowsze instrukcje dla Nie skategoryzowane

IFM

IFM PE2599 Instrukcja

3 Kwietnia 2025
IFM

IFM RU6035 Instrukcja

3 Kwietnia 2025
Bestway

Bestway 9102S Instrukcja

3 Kwietnia 2025
Bestway

Bestway 9102T Instrukcja

3 Kwietnia 2025
Bestway

Bestway 21177 Instrukcja

3 Kwietnia 2025
Bestway

Bestway 21178 Instrukcja

3 Kwietnia 2025
Ruggard

Ruggard GTUV-SG Instrukcja

3 Kwietnia 2025