Instrukcja obsługi Velleman HAM982K


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Velleman HAM982K (52 stron) w kategorii Bezpieczeństwo. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/52
HAM982K 1 VELLEMAN
HAM982K – HOME ALARM STARTER SET
Introduction
Thank you for buying the HAM982K! Please read the manual thoroughly before bringing this device into service.
If the device was damaged in transit, don't install or use it and contact your dealer.
The HAM982K home alarm set comprises:
1. 1 x electronic siren
2. 1 x AC power adapter
3. 1 x PIR detector
4. 5 x magnetic reed switches
5. 1 x panic button
6. 1 x 8-zone alarm control panel
These numbers refer to the chapters below.
1. Electronic Siren
5" horn speaker
Operating voltage 6-12Vdc
Peak output power 7W
Current consumption 600mA
Connection diagram: + =red wire
- = black wire
It is important to know if the N.O. contact is of the positive or the negative type. If it is a positive type, connection
should be made as shown above. If it is a negative type, the switch should be on the black (-) wire.
2. AC Power Adapter
Input voltage 230Vac 50Hz
Output voltage 16.5Vac
Output current 3000mA max.
Rated power factor cos φ 0.96
Protection built-in thermal & current fuse
Dimensions (LxWxH) 76 x 89.5 x 62mm
Weight 1.2kg
Connect the 16.5Vac output terminals to the device's input terminals. Make sure its power consumption does not
exceed the maximum rating of the adapter, and that the connection wires are firmly fixed to the terminals.
Then plug the power plug into a 230Vac mains socket.
The power adapter is for indoor use only.
HAM982K 2 VELLEMAN
1M 2M 3M 4M 5M 6M 7M 8M 9M 10M 11M 12M
0
1M
2M
3M
4M
5M
6M
7M
8M
1M
2M
3M
4M
5M
6M
7M
42.1
-42.1
3. PIR Detector
a. Technical Specifications
Detection element low noise dual element pyro sensor
Operating voltage 8-16Vdc ; 12Vdc nominal
Current consumption typical 15mA at 12Vdc
Power-up delay typical 2 minutes with flashing LED indication
Alarm period 2-3s
Alarm output N.C. relay contact with 10 in-line resistor. Contact rating: 28Vdc, 0.1A
Walk test with LED alarm indicator
Pulse counting Normal response or 2 pulses within 12 seconds for "harsh" environments
Tamper switch N.C. contact with 10 in-line resistor. Contact rating: 12Vdc, 50mA
Operating temperature -10 to +55°C
Humidity max 95% non-condensing
EMC conform to CE standard
Dimensions (HxWxD) 116 x 73.5 x 74mm
b. PCB layout
1. Pyro-sensor (do not touch this sensor!)
2. Walk test & alarm indicator
3. Tamper switch
4. Pulse count jumper ("harsh": for environment with high risk of false detection)
5. LED on/off jumper (on = flashing during start-up, on during operation)
6. Connection terminal block:
Tamper: if a tamper switch is required, connect these terminals to a 24h
normally closed (NC) zone in the alarm control panel. Opening the
housing will trigger a tamper signal.
12Vdc: connect (+) to an 8-16V power source, usually from the alarm control
panel. Connect (-) to the common grounding point.
Alarm: the alarm output relay of the detector. Connect these terminals to a
normally closed (NC) zone in the alarm control panel.
c. Installation
Install the detector indoors, on a stable surface with a clear view on the protection area.
Avoid mounting where hot or cold air may blow directly onto the device and where objects
in the detection field may change temperature rapidly (heating or air-conditioning devices).
Considering the detection angle of the device (see figure on the right), corner mounting is
recommended, at a height of 2 to 3 meters.
Procedure:
1. Open the cover by inserting a small screw driver into the edge of the unit and turning it to release the cover.
2. Remove the PCB by releasing the two fixing screws from the support post - DO NOT DROP THE PCB!
3. Numerous "knockouts" are provided on the back plate. Punch the one which will provide the best cable entry.
4. The two fixing holes on the back of the back plate are for surface mounting. The two fixing holes on the left and
right of the back plate are for corner mounting. Fix the back plate firmly on the wall with the two enclosed screws.
5. Put the PCB back onto the back plate and fix it firmly. Connect the wires to the terminal block.
6. Clip the front cover back in place on the back plate. See to it that the tamper switch is depressed when the front
cover is in place.
HAM982K 3 VELLEMAN
d. Testing
a. Apply 12V DC power and allow 3-5 minutes for the detector to warm up and stabilise before testing.
b. Walk into the protected area at a speed of 1 step per second and watch the LED.
c. The alarm will be triggered when movement is detected. If the pulse count jumper is set to "harsh", 2 detections
need to be made in 12 seconds time for the alarm to be triggered.
d. If proper detection does not occur during the walk tests, relocating or re-aiming the detector may be required.
4. Magnetic Reed Switches
magnetic switch, standard type
white ABS
mounting with screws or double-sided tape
operating gap: max. 15mm
dimensions: 51 x 13 x 13mm.
5. Panic button
NC & NO alarm circuit connection
screw connectors
momentary contact (off / on)
contact rating: 0.5A / 24Vdc max
colour: ivory
dimensions: 76 x 22.5 x 16mm
6. Control Panel
a. Front Panel
LEDs ON OFF FLASHING
zone LEDs (8)
zone unsealed – wire is
possibly disconnected. Zone sealed (normal)
fast: zone is/was in alarm
fast with interval: zone is in alarm memory –
system disarmed
slow: zone is isolated
exit/armed alarm armed alarm disarmed exit delay period
AC power failure, system runs on battery
(flashing starts 20-30s after power failure)
AC power system on AC power
'AC power' & 'battery' flashing alternatively:
system is in power-up delay period
battery battery faulty normal
battery is under test
program system in program mode
normal
arm prohibited
system in arm prohibited
mode: indicator is on
during exit delay period
System armed (exit delay
expired)
System forced to arm
system cannot be armed after exit delay
expired due to faulty zone(s) – see zone
indicators for the faulty zone(s)


Specyfikacje produktu

Marka: Velleman
Kategoria: Bezpieczeństwo
Model: HAM982K

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Velleman HAM982K, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Bezpieczeństwo Velleman

Velleman

Velleman HAM982K Instrukcja

12 Września 2024

Instrukcje Bezpieczeństwo

Najnowsze instrukcje dla Bezpieczeństwo