Fresh Air Systems - 150 CFM
parts motor/
controls
hrv core
The industry’s most advanced residential fresh air system, created to offer a
universal platform specifically designed and improved to make contractors
life easier and more profitable while delivering constant superior air
quality.
product specifications subject to change without notice .
Polypropylene crossflow core, impact resistant
Dimensions: 12" x 12" x 9" (30.5 cm x 30.5 cm x 23 cm)
MERV 8 grade washable standard filter (included)
Optional MERV 13 grade filter part no. V242851
Optional HEPA media type filter part no. V25000
Compatible with the Tandem transition (part no. 14690)
(recommended for installations producing up to 110 CFM
only)
HRV
Top ports: V150H75NT
Side ports: V150H75NS
SRE of 77% at 0°C and 63% at -25°C (64 CFM, 30 L/s)
Ports size: 5 in.
Negative pressure defrost (exhaust defrost)
Corrosion resistant galvanized steel door and cabinet
One-piece molded insulation shell, no air leakage
(expanded polystyrene; UL 94 HF-1 certified)
Virtuo constant airflow and auto-balancing device (patent
pending)
Motorized dampers (no additional backdraft dampers required)
Integrated "snap-in" drain system installed in seconds with no
additional parts (drain hose included)
6’ power cord
Unit electrical characteristics:120 volts, 60 Hz, 2.4 A, 163 W
core
Filters
options
Thanks to the Virtuo Air TechnologyTM, the airflow calibration
and auto-balancing are achieved quickly and maintained
throughout the life of the product
Select the desired CFM (from 35 to 150 CFM, 17 to 71 L/s)
using the proven integrated LCD screen. The airflow is then set
up automatically
Integrated electronic airflow measurement device with real
time LCD
Integrated diagnostic tool
Equipped with PMSM ECM motors for a very low power
consumption
Suspended installation (chains included)
OR
Wall-mount installation (universal brackets included)
installation with 2 brackets
installation with 4 brackets
There are 3 optional main controls and 2 optional auxiliary
controls available. Refer to Wall Control specification sheet for
more information.
aUtomatic
a D v a n c e D
toUchscreen
20-40-60
DelUxe
35 to 150 CFM (17 to 71 L/s) @ 0.2 in. w.g.
35 to 140 CFM (17 to 66 L/s) @ 0.4 in. w.g.
F
a
b
r
i
q
u
é
a
u
M
a
d
e
i
n
CANAD
A
CANAD
CANAD
CANAD
CANADA
A
A
A
G
A
R
A
N
T
I
E
L
I
M
I
T
É
E
L
I
M
I
T
E
D
W
A
R
R
A
N
T
Y
LIFETIME
LIFETIME
LIFETIME
LIFETIME
LIFETIME
À VIE
À VIE
À VIE
À VIE
À VIE
DehUmiDistat
1
Airflow performances associated with MERV 13 optional filter are not HVI certified. However, from tests performed by the manufacturer, such
performances are not affected by the use of this filter.
FRESH AIR
TO BUILDING
EXHAUST AIR
TO OUTSIDE
EXHAUST AIR
FROM BUILDING
FRESH AIR
FROM OUTSIDE
8" (20.32 CM)
CLEARANCE REQUIRED
IN FRONT OF DOOR
FOR MAINTENANCE
19/8"
(48.58 CM)
219/16"
(54.77 )CM
1¼"(3.18 CM)
207/16"
(51.91 )CM
SCREW
FIXATION
18¾" (47.63 )CM
21" (53.34 CM)
16" (40.64 CM)
16/8" (40.96 )CM
11/8"
(28.26 CM)
11/8"
(28.26 CM)
3/16" (9.37 CM) 3/16" (9.37 )CM
VK0126A
4/8" (10.48 )4/ CM8" (10.48 )CM
4½" (11.43 )4½" (1 CM1.43 )CM
21½"
(54.61 )CM
5 p"orts imensions op orts D (t p )
5 p"orts imensions iDe orts D (s p )
Total assembled weight: approx 35 lbs (15.9 kg) (core included)
Shipping weight: approx 42 lbs (19 kg)
Total assembled weight: approx 35 lbs (15.9 kg) (core included)
Shipping weight: approx 42 lbs (19 kg)
18¾" (47.63 )CM
8" (20.32 CM)
CLEARANCE REQUIRED
IN
FRONT OF DOOR
FOR MAINTENANCE
21" (53.34 )CM16/8" (40.96 )CM
16" (40.64 CM)
4/16"
(12.38 CM)
4/16"
(12.38 CM)
VK0125A
23/8" (59.37 )CM 4/16"
(12.38 CM)
207/16"
(51.91 CM)
SCREW
FIXATION
4/16"
(12.38 )CM
19/8"
(48.58 )CM
21
9/16"
(54.77 CM)
1¼"(3.18 CM)
11/8"
(28.26 CM)
3/16" (9.37 )CM
FRESH AIR
TO BUILDING
EXHAUST AIR
TO OUTSIDE
3/16" (9.37 )CM
EXHAUST AIR
FROM BUILDING
FRESH AIR
FROM OUTSIDE
11/8"
(28.26 CM)
DeFrost ystem s
F can Urves with irtUo v
Defrost by negative pressure
(exhaust defrost)
Defrost is activated at a temperature
of -5°C (23°F) and lower as specified
within the table.
During the defrost sequence, the
supply blower shuts down and
the exhaust blower continues to
operate. The unit then returns to
normal operation and continues
the cycle.
Thanks to Virtuo Air TechnologyTM, no need to balance the unit manually. Both PMSM motors are controlled by an artificial intelligence
performing 120 readings per minute then processing this information to maintain the requested airflow.
For typical installation, Virtuo will ensure a balanced ventilation at every selected speed regardless of the weather conditions, the type of
connection, the variable speed furnace/AHU, the stack effect, the filter clogging and so on. This results in peace of mind for installers and
users knowing that the unit will always remain balanced and that it will maintain its maximum heat/energy recovery efficiency.
d iscretion
(Factory setting) o t *utdoor emperature
-5°c -15°cto
23°f 5°fto
-15°c -27°cto
5°f -17°fto
-27°c and less
-17°f and less
cfm a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
0 to 59
35 910 24 16 10
60 to 90
50 32 9 2010 10
91 and more
24 10 1018 9 13
* Outdoor temperature is read by a thermistor located inside the unit, next to fresh air from
outdoor port.
p o t *lus utdoor emperature
-5°c -15°cto
23°f 5°fto
-15°c -27°cto
5°f -17°fto
-27°c and less
-17°f and less
cfm a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
a ir exchange
in minutes
d efrost in
minutes
0 to 59
27 10 10 1021 14
60 to 90
38 10 27 10 1017
91 and more
20 10 10 1016 11
* Outdoor temperature is read by a thermistor located inside the unit, next to fresh air from
outdoor port.
y = 5E 6x-0
3
- 0.0021x
2
+ 0.2659x - 9.7283
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
External Stac Pressure (IN. W.G.)
Gross ai rflow(CFM)
AIRFLOW IS FULLY ADJUSTABLE WITH 1 CF CR TM IN EMEN
static
pressure
(pa)
1.0static
pressure
( . . .)in w g
net
supply
airflow
(l/ )s
n et
supply
airflow
( )cfm
gross
airflow
supply
(l/ )s
gross
airflow
supply
( )cfm
gross
airflow
exhaust
(l/ )s
gross
airflow
exhaust
( )cfm
25 730.1 155 74 74157 157
50 0.2 72 7271 150 153 153
75 0.3 68 69 69144 146 146
100 0.4 66 140 142 14267 67
125 0.5 65 6564 136 138 138
150 0.6 62 63 63131 133 133
175 0.7 60 127 61 61129 129
200 0.8 58 5857 121 123 123
225 0.9 55 5554 114 117 117
250 52 521.0 51 108 110 110


Specyfikacje produktu

Marka: VänEE
Kategoria: klimatyzacja
Model: V150H75NT

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z VänEE V150H75NT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje klimatyzacja VänEE

VänEE

VänEE V150H75NT Instrukcja

9 Października 2024
VänEE

VänEE V150E75NT Instrukcja

9 Października 2024
VänEE

VänEE 44252 Instrukcja

9 Października 2024
VänEE

VänEE 1601510 Instrukcja

9 Października 2024
VänEE

VänEE V160E65RT Instrukcja

9 Października 2024
VänEE

VänEE V180E75RT Instrukcja

7 Października 2024
VänEE

VänEE V150H75NS Instrukcja

7 Października 2024
VänEE

VänEE V160H75RS Instrukcja

7 Października 2024
VänEE

VänEE V160H80RT Instrukcja

7 Października 2024

Instrukcje klimatyzacja

Najnowsze instrukcje dla klimatyzacja