3-Phase Monitored & Switched
0U Power Distribution Units
(Phase, Bank, Outlet Measurements*)
208V MONITORED
MODELS SERIES NO.
PDU3EVN3L2130 AG-00B9
PDU3EVN10L2130 AG-00B9
PDU3EVN3L2120 AG-00B8
PDU3EVN6L2120 AG-00B8
PDU3EVN10L2120 AG-00B8
PDU3EVN6L2130 AG-00B9
208V SWITCHED
MODELS SERIES NO.
PDU3EVSR6G60A AG-0094
PDU3EVSR6H50A AG-0094
200 – 240V
MONITORED
MODELS SERIES NO.
PDU3EVN6G30B AG-00BA
PDU3EVN10G30B AG-00BA
PDU3EVN3G60B AG-00BA
PDU3EVN6G60B AG-00BA
PDU3EVN10G60B AG-00BA
PDU3EVN3H50B AG-00BA
PDU3EVN6H50B AG-00BA
PDU3EVN10H50B AG-00BA
PDU3EVN3L1530B AG-00BA
PDU3EVN6L1530B AG-00BA
PDU3EVN10L1530B AG-00BA
PDU3EVN3L2130B AG-00BA
PDU3EVN6L2130B AG-00BA
PDU3EVN10L2130B AG-00BA
PDU3EVN6G60C AG-00BB
200 – 240V
SWITCHED
MODELS SERIES NO.
PDU3EVSR6H50 AG-00BA
PDU3EVSR10H50 AG-00BA
PDU3EVSR6L1530 AG-00BA
PDU3EVSR10L1530 AG-00BA
PDU3EVSR6L2130 AG-00BA
PDU3EVSR10L2130 AG-00BA
PDU3EVS6H50 AG-00BA
PDU3EVS6L2130 AG-00BA
PDU3EVS6L2120 AG-00BC
PDU3EVSR6L2120 AG-00BC
PDU3EVSR6L1520 AG-00BC
380 – 415V
MONITORED
MODELS SERIES NO.
PDU3XEVN6G20 AG-00BD
380 – 415V
SWITCHED
MODELS SERIES NO.
PDU3XEVSR6G20 AG-00BD
PDU3XEVSR6G30A AG-0096
PDU3XEVSR6G30B AG-0096
PDU3XEVSR6G32A AG-0096
PDU3XEVSR6G32B AG-0080
PDU3XEVSR6G60A AG-0096
PDU3XEVSR6G60B AG-0093
PDU3XEVSR6G63A AG-0096
PDU3XEVSR6G63B AG-0094
PDU3XEVSR6L230B AG-0056
PDU3XEVSR6L2230 AG-0096
PDU3XEVSRHWA AG-0096
PDU3XEVSRHWB AG-0057
Español 17 • Français 33 49Русский
17-06-566-93349E.indb 1 9/18/2017 4:23:16 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation, and storage of this product. Failure to heed these
instructions and warnings may affect the product warranty.
The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
The PDU must be installed by a qualified technician only.
Do not attempt to mount the PDU to an insecure or unstable surface.
Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
Connect the PDU to an outlet that is in accordance with your local building codes and that is
adequately protected against excess currents, short circuits and earth faults.
The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
Never attempt to install electrical equipment during a thunderstorm.
Individual equipment connected to the PDU should not draw more current than the individual
PDU’s outlet’s rating.
The total load connected to the PDU must not exceed the maximum load rating for the PDU.
Do not attempt to modify the PDU, input plugs or power cables.
Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
Do not attempt to use the PDU if any part of it becomes damaged.
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to signicantly
affect its safety or effectiveness is not recommended.
17-06-566-93349E.indb 2 9/18/2017 4:23:16 PM
1-1 1-2
1-4
1-3
1-5
A
B
3
Installation
Mounting the PDU
Note: The illustrations may differ somewhat from your PDU model. Regardless of conguration, the user must
determine thetness of hardware and procedures before mounting. The PDU and included hardware are designed
for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting
configurations may vary. Screws for attaching the mounting brackets to the PDU are included. Use only the screws
supplied by the manufacturer or their exact equivalent.
Note: Mounting buttons come preinstalled to the PDU for toolless mounting.
1-1 To attach the mounting brackets to the
PDU, remove the mounting buttons.
1-2 Attach the mounting brackets to the
PDU with the included screws.
1-3 Attach the PDU to a vertical rail in
your rack or rack enclosure. (Use the
mounting hardware that came with your
rack or rack enclosure to attach the
mounting brackets to the rail.)
1-4 To reinstall the mounting buttons for
toolless mounting, remove the mounting
brackets then install the mounting
buttons onto the PDU. Position the PDU
as desired in the rack enclosure, align
the buttons with the rack mounting
slots, and slide the PDU into position.
Note: Be sure to insert the 2 buttons into either
the upper hole at of the PDU or into each end
the lower hole at of the PDU.each end
1-5 To install the PDU with its outlets facing
the rear of the rack, use the included
PDUMVROTATEBRKT accessory. First,
attach the mounting button A to the
V-shaped bracket B using the included
screw and washer. Then, use the
button-mount slot to attach the bracket
to the PDU and the mounting button to
attach the PDU to the rack. The bracket
effectively repositions the mounting
brackets allowing for the PDU outlets to
face the rear of the rack.
17-06-566-93349E.indb 3 9/18/2017 4:23:25 PM


Specyfikacje produktu

Marka: Tripp Lite
Kategoria: blok przedłużający
Model: PDU3EVSR6L1530
Kolor produktu: Czarny
Materiał obudowy: Metal
Wbudowany wyłącznik: Tak
Częstotliwość wejściowa AC: 50 - 60 Hz
Wysokość produktu: 1778 mm
Szerokość produktu: 55.1 mm
Głębokość produktu: 72.6 mm
Waga produktu: 9080 g
Długość kabla: 1.83 m
Podręcznik użytkownika: Tak
Szerokość opakowania: 245.1 mm
Wysokość opakowania: 175 mm
Głębokość opakowania: 1927.1 mm
Certyfikat środowiskowy (zrównoważonego rozwoju): RoHS
Certyfikaty: Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada)\nClass A Part 15 (Emissions)\nNOM (Mexico)\nTAA Compliant
Kraj pochodzenia: Tajwan
Maksymalna moc: 10000 W
Zakres temperatur (eksploatacja): 0 - 50 °C
Zakres wilgotności względnej: 5 - 95 %
Waga wraz z opakowaniem: 12280 g
Diody LED: Tak
Zakres temperatur (przechowywanie): -15 - 60 °C
Model: Trójfazowy
Maksymalna temperatura termometru zwilżonego (wet bulb temp.) Podczas eksploatacji (w °f): 32 - 122 °F
Wymiary produktu (SxGxW): 55 x 73 x 1778 mm
Wymiary opakowania (SxGxW): 175 x 245.1 x 1927.1 mm
Maksymalne natężenie prądu: 24 A
Dopuszczalna wysokość podczas eksploatacji (n.p.m.): 0 - 3000 m
Obsługiwane protokoły sieciowe: HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP
Produkty w skrzyni głównej (zewnętrznej): 1 szt.
Typ montażu: Pionowy
Pojemność stelaża: 0U
Ilość gniazd sieciowych: 30 x gniazdo sieciowe
Typy wyjść AC: C13 coupler, C19 coupler
Wartość nominalna napięcia wyjściowego: 200-240 V
Wartość nominalna napięcia wejściowego: 200-240 V
Funkcje ochrony zasilania: Krótkie spięcie
Wtyczka: NEMA L15-30P
Typy PDU: Przełączane
Monitoring: Zasilanie
Sterowanie ujścia: Lock-out, Recycle, Turn off, Turn on
Ilość gniazd AC master: 24
Ilość gniazd AC slave: 6