Instrukcja obsługi Tripp Lite Metered PDUMH20-ISO

Tripp Lite blok przedłużający Metered PDUMH20-ISO

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Tripp Lite Metered PDUMH20-ISO (12 stron) w kategorii blok przedłużający. Ta instrukcja była pomocna dla 34 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/12
1
Metered Rack PDU
Important Safety Instructions 2
Important Warnings 2
Installation 3
Features 4
Warranty & Warranty Registration 4
Español 5
Français 9
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
14-02-330-932567.indb 1 4/23/2014 3:58:20 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will void the
product warranty.
Important Warnings
• ThePDUprovidesconvenientmultipleoutletsbutitDOESNOTprovidesurgeor 
linenoiseprotectionforconnectedequipment.
• ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfromexcessmoisture,
temperatureextremes,conductivecontaminants,dustordirectsunlight.
• DonotconnectthePDUtoanungroundedoutletorextensioncordsoradaptersthateliminate
theconnectiontoground.
• ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmustnotexceedthe
individualoutlet’sloadrating.
• ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceedthe
maximumloadratingforthePDU.
• DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-serviceable
partsinside.
• DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
• DonotattempttousethePDUifanypartofitbecomesdamaged.
• DonotattempttomountthePDUtoaninsecureorunstablesurface.
• Neverattempttoinstallelectricalequipmentduringathunderstorm.
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentortosignificantly
affectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaflammableanestheticmixturewithair,oxygenornitrousoxide.
14-02-330-932567.indb 2 4/23/2014 3:58:20 PM
3
Installation
Note: The illustrations may differ somewhat from your PDU
model.
1 Determine Installation Configuration.ThePDU
supportsfourprimaryinstallationconfigurations:1U
Rack,0URack,WallandUnder-Counter.Choosea
configurationandfollowtheinstallationinstructions
intheappropriatesectionofStep1before
proceedingtoStep2.
Note: Regardless of installation configuration, the
user must determine the fitness of hardware and
procedures before mounting. The PDU and included
hardware are designed for common rack and rack
enclosure types and may not be appropriate for all
applications. Exact mounting configurations may vary.
1-1 1U Rack Installation.AttachthePDUtotherackby
insertingfouruser-suppliedscrews( )throughtheA
PDUmountingbrackets( )andintothemountingB
holesoftherackrailasshown.
1-2 0U Rack Installation. Part 1:Removethescrews
( )attachingthemountingbracketstothePDU,C
changetheorientationofthebracketsasshownand
reattachthebrackets.Useonlythescrewssupplied
bythemanufacturerortheirexactequivalent(#6-
32,1/4”flathead). AttachthePDUvertically Part 2:
byinsertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets( )andintoB
mountingpointsintherackorrackenclosure.
1-3 Wall Installation. AfterrepeatingPart1above,
attachthePDUtoastablemountingsurfaceby
insertingtwoormoreuser-suppliedscrews(A)
throughthePDUmountingbrackets( )andintoB
securemountingpointsonthemountingsurface.
1-4 Under-Counter Installation. AfterrepeatingPart1
above,attachthePDUtoastablemountingsurface
byinsertingfouruser-suppliedscrews( )throughtheA
PDUmountingbrackets( )andintosecuremountingB
pointsonthemountingsurface.
2 Attach the input plug of the PDU to a grounded
outlet. Inserttheplugdirectlyintoagroundedoutlet
thatdoesnotshareacircuitwithaheavyelectrical
load(suchasanairconditionerorrefrigerator).
2
1-1
1-2
1-3
1-4
A
B
B
A
C
A
B
C
B
C
A
C
3
Note: Select models include an input plug adapter that converts the twist-lock input plug to a
straight-blade input plug. Attach the input plug adapter to the input plug if you wish to plug
the PDU into a compatible straight-blade outlet.
3 Attach equipment to the PDU. DonotexceedtheloadratingofthePDU.Thetotalelectrical
currentusedbythePDUwillbedisplayedonthedigitalmeterinamperes.
14-02-330-932567.indb 3 4/23/2014 3:58:22 PM


Specyfikacje produktu

Marka: Tripp Lite
Kategoria: blok przedłużający
Model: Metered PDUMH20-ISO
Kolor produktu: Czarny
Materiał obudowy: Metal
Wysokość produktu: 50.8 mm
Szerokość produktu: 508 mm
Głębokość produktu: 114.3 mm
Waga produktu: 2090 g
Długość kabla: 4.57 m
Szerokość opakowania: 520.7 mm
Wysokość opakowania: 57.2 mm
Głębokość opakowania: 254 mm
Certyfikat środowiskowy (zrównoważonego rozwoju): RoHS
Certyfikaty: UL1449\r\nCSA
Kraj pochodzenia: Chiny
Typ ekranu: LED
Zakres temperatur (eksploatacja): -15 - 50 °C
Zakres wilgotności względnej: 5 - 95 %
Waga wraz z opakowaniem: 3220 g
Wysokość skrzyni wzorcowej (zewnętrznej): 247.6 mm
Długość skrzyni głównej (zewnętrznej): 349.2 mm
Waga brutto obudowy głównej (zewnętrznej): 10070 g
Szerokość skrzyni zbiorczej (zewnętrznej): 527 mm
Diody LED: Tak
Wymiary produktu (SxGxW): 444.5 x 114.3 x 44.5 mm
W opakowaniu zbiorczym GTIN (EAN / UPC): 10037332185706
Wymiary opakowania (SxGxW): 520.7 x 254 x 57.2 mm
Maksymalne natężenie prądu: 20 A
Dopuszczalna wysokość podczas eksploatacji (n.p.m.): 0 - 3000 m
Produkty w skrzyni głównej (zewnętrznej): 6 szt.
Typ montażu: Poziome
Pojemność stelaża: 1U
Ilość gniazd sieciowych: 14 x gniazdo sieciowe
Typy wyjść AC: NEMA 5–15R, NEMA 5–20R
Wartość nominalna napięcia wyjściowego: 100-127 V
Wartość nominalna napięcia wejściowego: 100-127 V
Wtyczka: NEMA 5–20P
Typy PDU: Regulowany