Owner’s Manual
ECO-UPS™ Systems with LCD
Models: ECO650LCD, ECO850LCD
Not suitable for mobile applications
Important Safety Instructions 2
Basic Operation 3
UPS On/Off 3
LCD Features 3
Display Power Conditions 3
ECO Energy-Saving Feature 3
Enable/Disable Alarm 3
LCD Brightness 4
Self-test 4
Error Messages 4
Features 4
Storage and Service 5
Warranty Registration 6
Español 7
Français 13
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2010 Tripp Lite. All rights reserved.
The ECO Energy-Saving Feature allows your UPS to save energy by automatically turning off
designated outlets when your computer is off or in standby mode. When the UPS detects
that your computer has been turned off or in standby mode for 3 minutes, it will turn off the
outlets marked “ECO”. The 3 minute delay ensures that the outlets remain powered during a
reboot, momentary cable disconnection or similar transitory event.
201010198.indb 1 12/21/2010 11:47:34 AM
Important Safety Instructions
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings may
affect the warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F
(0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS
into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be
voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to
an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This might
damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS
or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn
off the UPS before performing battery replacement. Use tools with insulated handles. There
are no user-serviceable parts inside the UPS. Battery replacement should be performed
only by authorized service personnel using the same number and type of batteries (Sealed
Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal
requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling information. Tripp
Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit
Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific
replacement battery for your UPS.
• Do not attempt to add external batteries to the UPS.
201010198.indb 2 12/21/2010 11:47:34 AM
Basic Operation
3
UPS ON/OFF
•PlugtheUPSintoagroundedoutlet.
•TurntheUPSon:Press and hold the button for 2 seconds. The UPS alarm will beep
once briefly after 2 seconds have passed.
•PlugequipmentintotheUPS:Select outlets will provide battery backup and surge
protection; connect your computer, monitor and other critical devices here.* Select outlets
will provide surge protection only; connect your printer and other nonessential devices
here.
•TurntheUPSoff:Press and hold the button for 2.5 seconds. The UPS alarm will
beep once after 2.5 seconds have passed.
* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings for
all the equipment you connect to the “Battery, Surge and Noise Protected” outlets exceeds the UPS’s Output
Capacity. To estimate your equipment’s power requirements, look on the nameplates. If the equipment is
listed in amps, multiply the number of amps by 120 to determine VA, (Example: 1 amp x 120 = 120 VA).
Your UPS is fully loaded when the display indicates 100% load.
LCD Features
Tap the button to advance from one display to the next. Use the button to toggle
settings for ECO, Alarm, LCD Brightness and Self-test functions. When the preferred setting
has been selected, continue by pressing the button. If the screen is idle for 20 seconds,
the LCD will return to the home screen, retaining the last selected settings.
Display Power Conditions
Use the button to advance through power conditions.
• Voltage In
• Voltage Out
• Estimated Runtime (in minutes)
• Load %*
• Load Wattage*
• Battery Capacity %
* Display measurement represents battery backup protected outlets only.
ECO Energy-Saving Feature
Use the included USB cable to connect your UPS to your computer. Connect nonessential
equipment to the ECO outlets, marked “ECO” on your UPS system. Make sure that any
devices connected to the ECO outlets can be turned off without interrupting your Internet
connection, local network, or other essential services. While your UPS is turned on and
operating normally from utility power, tap the button repeatedly to advance the LCD
display to the screen marked “ECO”. Use the button to enable the ECO function.
Enable/Disable Alarm
Tap the button repeatedly to advance to the LCD display featuring the icon. Press the
button to select enable or disable alarm mode settings.
201010198.indb 3 12/21/2010 11:47:34 AM
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | zasilacz UPS |
Model: | ECO650LCD |
Kolor produktu: | Czarny |
Wysokość produktu: | 83.3 mm |
Szerokość produktu: | 279.9 mm |
Głębokość produktu: | 150.1 mm |
Waga produktu: | 2200 g |
Długość kabla: | 1.8 m |
Szerokość opakowania: | 327.7 mm |
Wysokość opakowania: | 104.1 mm |
Głębokość opakowania: | 205.7 mm |
Certyfikat środowiskowy (zrównoważonego rozwoju): | RoHS |
Certyfikaty: | UL1778\nCSA\nNOM\nFCC Part 15 Category B\nFCC Part 68 |
Kraj pochodzenia: | Chiny |
Wydajność: | 95 % |
Zakres temperatur (eksploatacja): | 0 - 40 °C |
Liczba portów USB 2.0: | 1 |
Waga wraz z opakowaniem: | 2540 g |
Wysokość skrzyni wzorcowej (zewnętrznej): | 238.8 mm |
Długość skrzyni głównej (zewnętrznej): | 332.7 mm |
Waga brutto obudowy głównej (zewnętrznej): | 10700 g |
Szerokość skrzyni zbiorczej (zewnętrznej): | 419.1 mm |
Częstotliwość danych wejściowych: | 60 Hz |
Diody LED: | Tak |
Zakres temperatur (przechowywanie): | -15 - 50 °C |
Standardowe rozwiązania komunikacyjne: | USB |
W opakowaniu zbiorczym GTIN (EAN / UPC): | 10037332161304 |
Wymiary opakowania (SxGxW): | 330 x 203 x 108 mm |
Maksymalne natężenie prądu: | 15 A |
Wilgotność względna: | 0 - 95 % |
Produkty w skrzyni głównej (zewnętrznej): | 4 szt. |
Moc rzeczywista: | 325 W |
Maksymalna możliwa do konfiguracji moc: | 0.65 kVA |
Wartość znamionowa udaru energii: | 420 J |
Słyszalny alarm: | Tak |
Ilość gniazd sieciowych: | 8 x gniazdo sieciowe |
Typy wyjść AC: | NEMA 5–15R |
Porty modemu rj-11: | 1 |
Typowy czas podtrzymania przy połowie obciążenia: | 10 min |
Typowy czas podtrzymania przy pełnym obciążeniu: | 3 min |
Wartość nominalna napięcia wyjściowego: | 120 V |
Wartość nominalna napięcia wejściowego: | 120 V |
Topologia UPS: | Czuwanie (Offline) |
Filtr EMI/RFI: | Tak |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite ECO650LCD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje zasilacz UPS Tripp Lite
7 Maja 2024
6 Maja 2024
6 Maja 2024
Instrukcje zasilacz UPS
- zasilacz UPS APC
- zasilacz UPS FSP
- zasilacz UPS Emerson
- zasilacz UPS CyberPower
- zasilacz UPS Adj
- zasilacz UPS PowerWalker
- zasilacz UPS Ditek
- zasilacz UPS Murr Elektronik
Najnowsze instrukcje dla zasilacz UPS
19 Września 2024
9 Lipca 2024
9 Lipca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024
18 Czerwca 2024