Instrukcja obsługi Sussex VEBM120

Sussex Dźwig VEBM120

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Sussex VEBM120 (1 stron) w kategorii Dźwig. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/1
7.5
Licence No. 0124
In ac cord anc e with AS/NZS 6400
Sussex Taps Pty Ltd
WATER RATING
www.waterr ating.g ov.au
The mo re
stars the mo re
water efcient
Mounting
Surface
Fixing
Nut Flexible Hose
Clamp
Optional
Base Flange
Hose extension
(Do not remove)
32 - 35mm
Product code
Installation guidelines
Plumber note
Voda
- The Mixer is supplied assembled, only the Fixing nut and the Brass Clamp need to be removed.
- Decide if the Optional Base Flange is to be used.
- If using the Optional Base Flange discard the smaller Base O Ring.
- Add the base Flange to base of Mixer and attach the Flexible Hoses to the Mixer Hose extensions.
- In some cases the Flexible Hoses may need to be fed through from under the mounting surface and then attach.
- Once the Flexible Hoses have been secured, lower the Mixer onto the mounting surface.
- Working from underneath the mounting surface fit Clamp and Fixing Nut.
- Before fully securing the Mixer ensure that the Base O Ring is intact and the Mixer is centered over the
mounting surface hole.
- The Mixer mounting surface must be completely water-tight.
- Connect the Hot and Cold Flexible hoses to the corresponding 1/2”BSP water feed lines.
- The 1/2” connection of the Flexible hoses have a conical seal, ensure the mating threads are cut square and
burr free.
- Isolating stop valves are recommended with all installations (not supplied).
- Ensure all fittings and connections are water-tight.
Note: Optional Base Flange must be used when the clearance hole for mounting the Mixer exceeds 35mm.
If the mounting hole clearance exceeds 45 mm a custom made Base flange will be required.
- On-site testing using higher water pressures must be conducted with the Mixer in the closed position.
(STATIC TEST)
- Under no circumstances is the Mixer to be opened when exceeding the maximum stated water pressure.
- At the completion of testing, do not relieve any high water pressure by operating the Mixer.
- Exposing the internals of the Mixer Car tridge to higher than specified water pressures will void the
manufacturers warranty.
VBM Basin mixer
VEBM Extended basin mixer 90mm outlet
VEBM120 Extended basin mixer 120mm outlet
VMBM Medium basin mixer 90mm outlet
VMBM120 Medium basin mixer 120mm
VBMSS Basin mixer 316 S/S
Basin mixer
sussextaps.com.au
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003
Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.


Specyfikacje produktu

Marka: Sussex
Kategoria: Dźwig
Model: VEBM120

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Sussex VEBM120, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Dźwig Sussex

Sussex

Sussex BMDSRH Instrukcja

9 Października 2024
Sussex

Sussex BLMDSRH Instrukcja

9 Października 2024
Sussex

Sussex VEBM120 Instrukcja

3 Października 2024
Sussex

Sussex BWBMS210RH Instrukcja

3 Października 2024
Sussex

Sussex RWBHS200RH Instrukcja

3 Października 2024
Sussex

Sussex RBS Instrukcja

2 Października 2024
Sussex

Sussex BLWBMS210RH Instrukcja

2 Października 2024
Sussex

Sussex DPWBMS200 Instrukcja

2 Października 2024
Sussex

Sussex DBSHMSH Instrukcja

2 Października 2024
Sussex

Sussex BLBM Instrukcja

2 Października 2024

Instrukcje Dźwig

Najnowsze instrukcje dla Dźwig