Instrukcja obsługi Steren INT-300
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Steren INT-300 (54 stron) w kategorii Interkom. Ta instrukcja była pomocna dla 2 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek
Strona 1/54
Air conditioner
Installation manual
AM***TXMDEH
࡙Thank you for purchasing this Samsung air conditioner.
࡙Before operating this unit, please read this installation manual carefully and retain it for
future reference.
DB68-08875A-00
2
Contents
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Outdoor unit type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation combination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Deciding to where to install the outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation and base ground work for an outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Refrigerant pipe installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wiring work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Grounding work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Setting outdoor unit option switch and key function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Charging refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Pump Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Checking lists after nishing installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Inspection and check operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Trial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate
these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material
resources.
Household users should contact either the retailer where they purchased this product, or their local government
oce, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product and its electronic accessories should not be mixed with other commercial wastes for disposal.
3
ENGLISH
Safety precautions
Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.
WARNING
t Always disconnect the air conditioner from the power supply before servicing it or
accessing its internal components.
t Verify that installation and testing operations are performed by qualied personnel.
t Verify that the air conditioner is not installed in an easily accessible area.
General information
f Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order
to be able to use it as reference after installation.
f For maximum safety, installers should always carefully read the following warnings.
f Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air
conditioner is sold or transferred.
f This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types
of units with dierent control systems may damage the units and invalidate the warranty. The manufacturer shall not be
responsible for damages arising from the use of non compliant units.
f The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper
connection of electric and requirements set forth in the “Operating limits” table, included in the manual. Making such
changes or improper connections may damage the units and invalidate the warranty.
f The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable
to be installed in areas used for laundry.
f Do not use the units if damaged. If problems occur, switch the unit o and disconnect it from the power supply.
f In order to prevent electric shocks, res or injuries, always stop the unit, disable the protection switch and contact
SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
f Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations
should be performed by qualied personnel only.
f The unit contains moving parts, which should always be kept out of the reach of children.
f Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may
cause electric shocks or res.
f Do not place containers with liquids or other objects on the unit.
f All the materials used for the manufacture and packaging of the air conditioner are recyclable.
f The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with
current laws.
f The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air
conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly
and safely.
f This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use
of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
f When the product operates in heat mode during winter time, it operates protection mode when the outdoor
temperature drops below 0°C. Therefore, supply the power during winter time. If the power is not supplied, compressor
protection mode will not operate and cause product malfunction.
Specyfikacje produktu
Marka: | Steren |
Kategoria: | Interkom |
Model: | INT-300 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Steren INT-300, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Interkom Steren
18 Września 2024
18 Września 2024
Instrukcje Interkom
- Interkom Philips
- Interkom Hikvision
- Interkom Panasonic
- Interkom Alcatel
- Interkom Viking
- Interkom ORNO
- Interkom Vimar
- Interkom Dahua Technology
- Interkom Emos
- Interkom Somfy
- Interkom DiO
- Interkom DataVideo
- Interkom EtiamPro
- Interkom Planet
- Interkom Axis
- Interkom Elro
- Interkom ZKTeco
- Interkom Akuvox
- Interkom Busch-Jaeger
- Interkom Fibaro
- Interkom Hanwha
- Interkom Avidsen
- Interkom TOA
- Interkom Byron
- Interkom M-e
- Interkom Becken
- Interkom Smartwares
- Interkom Sygonix
- Interkom WHD
- Interkom Siedle
- Interkom Valcom
- Interkom Chacon
- Interkom Konig
- Interkom DoorBird
- Interkom Gira
- Interkom Russound
- Interkom Comelit
- Interkom Aiphone
- Interkom RTS
- Interkom Hollyland
- Interkom Leviton
- Interkom Ritto
- Interkom Syscom
- Interkom Pentatron
- Interkom CyberData Systems
- Interkom COMMAX
- Interkom Bintec-elmeg
- Interkom Eartec
- Interkom Gewiss
- Interkom Seco-Larm
- Interkom GEV
- Interkom Mobotix
- Interkom FlyingVoice
- Interkom Vibell
Najnowsze instrukcje dla Interkom
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024