WHOLE HOUSE EXTRACT UNITS- SELF-REGULATING VENTILATION GROUPS
OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
Whole house extract units OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
Whole house extract units that ensure
permanent renewal of air in single
dwelling houses or multi-dwelling
blocks (individually). The unit is
complemented with selfadjusting
extraction BAR valves, (installed in
kitchen, toilets, bathrooms) and self-
regulated air inlets located in the main
rooms (dining rooms, bedrooms).
This range has available a CO2 model
that adjusts the airflow according to
the CO2 concentration detected by the
sensor.
Versions
OZEO E ECOWATT 2 with wiring remote
control.
OZEO E ECOWATT 2 RF with
radiofrequency remote control.
OZEO E ECOWATT CO2 with
radiofrequency remote control and CO2
sensor.
Configuration
• Three-speed motor (two of them are
adjustable).
• 4 Ø125 mm extract air spigots, to use
in bathrooms and kitchens. Include
gasket and pivoting 9 possibility.
• 1 Ø125 mm outlet spigot pivoting
36.
• 3 caps to seal unused spigots.
• 1 template to facilitate fitting on the
ceiling or wall.
• Wireless proportional CO2 sensor for
OZEO-E ECOWATT CO2 model.
• Wireless remote control with 3 speeds
for OZEO-E ECOWATT RF model.
On the
ceiling
HORIZONTAL VERTICAL
On the
floor
On the wall
Flexibility
Alternative fitting Specific applications
Single
dwellings
VMC
Multi
dwelling
blocks VMC
www.solerpalau.com
244
WHOLE HOUSE EXTRACT UNITS- SELF-REGULATING VENTILATION GROUPS
OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
Whole house extract units OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
PERFORMANCE CURVES
CONTROL REMOTO CON
SONDA CO2
Wireless remote control,
with 3-speed or proportional
by CO2 sensor, within the
scope of supply of OZEO-E
ECOWATT CO2
CONTROL REMOTO
OZEO-E ECOWATT RF
Wireless 3-speed remote
control within the scope of
supply of OZEO-E ECOWATT RF
CONTROL REMOTO
OZEO-E ECOWATT CO2
Wireless 3-speed remote control
within the scope of supply of
OZEO-E ECOWATT CO2
50
0
5004003002001000
550
450
150
100
50
0
400
350
300
250
200
500
q
v
[m3/h
]
Pabs (W)
p
sf
[Pa]
1
2
3
OZEO E ECOWATT 2
TECHNICAL CHARACTERISTICS
Model Motor Voltage
(V)
Maximum
absorbed power
(W)
Maximum
absorbed current
(A)
Sound pressure radied
Lp(a) at 3m.
(dB(A))
OZEO E ECOWATT 2 EC 230 30 27 (300 m0,25 3/h - 100 Pa)
OZEO E ECOWATT 2 RF EC 230 30 27 (300 m0,25 3/h - 100 Pa)
OZEO E ECOWATT CO2 EC 230 48 0,4 28 (325 m3/h - 150 Pa)
0 100 200 300 400
0
50
100
150
200
250
300
350
400
450
0
10
20
30
40
50
60
70
80
q
v
[m3
/h
]
Pabs (W)
p
sf
[Pa]
1
2
3
0 100 200 300 400
0
50
100
150
200
250
300
350
400
450
0
10
20
30
40
50
60
70
80
q
v
[m3/h
]
Pabs (W)
p
sf
[Pa]
1
2
3
OZEO E ECOWATT 2 RF OZEO E ECOWATT CO2
Colored areas represent adjustment zones for each speed, by a
potentiometer.
www.solerpalau.com
245
WHOLE HOUSE EXTRACT UNITS- SELF-REGULATING VENTILATION GROUPS
OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
Whole house extract units OZEO E ECOWATT 2 / OZEO E ECOWATT CO2
OZEO-E / OZEO-E ECOWATT CENTRALIZED SELF-ADjuSTINg
1. Self-adjusting acoustic air inlets ECA.
2. Self-adjusting extraction valves BAR.
3. Exhaust valve BDOP
4. PVC or rectangular plastic ducts.
5. Whole house extract units OZEO-E ECOWATT.
6. Roof terminal cowl CT.
1
2
4
6
5
3


Specyfikacje produktu

Marka: Soler & Palau
Kategoria: nieskategoryzowany
Model: OZEO E ECOWATT 2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Soler & Palau OZEO E ECOWATT 2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Soler & Palau

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Meec Tools

Meec Tools 010-084 Instrukcja

6 Października 2024
Outwell

Outwell Scenic Road 250 Instrukcja

5 Października 2024
Impact

Impact QuikBalance Instrukcja

4 Października 2024
Impact

Impact CA-112 Instrukcja

4 Października 2024
Impact

Impact LS-BHA Instrukcja

4 Października 2024
Impact

Impact LKB-5C Instrukcja

4 Października 2024
Impact

Impact RST-001 Instrukcja

4 Października 2024