Instrukcja obsługi Rio Scanning Laser X60


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Rio Scanning Laser X60 (2 stron) w kategorii urządzenie do usuwania włosów. Ta instrukcja była pomocna dla 16 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
LAHC5
CLASS 1 PRODUCT
CONTAINING
CLASS 3B LASER
808nm
wavelength
Wearing laser
safety goggles is
unnecessary as
the product has
been designed
with inbuilt safety
features.
PATENTS PENDING
This product MUST be used responsibly.
Please read these Instructions carefully
before use.
Refer to your Information Guide for:
• WARNINGS
• SECURITYBUTTONSEQUENCE
• HOWDOLASERSWORK?
• SUITABLESKINTYPES
• PATCHTEST
• HAIRGROWTHCYCLE
• WHYISASERIESOFTREATMENTS
REQUIRED?
• YOURQUESTIONSANSWERED
• TROUBLESHOOTING
SALON ASERL
SCANNING HAIR REMOVER x60
W A R N I N G S
• Readallinstructionsthoroughlyandretainforfuturereference.
Not suitableforAfro-Caribbean,black skincomplexionsor forGreyHair.
See“SuitableSkinTypes”inInformationGuide.
• Laserhairremovalshouldnotcausediscomfort,youmayfeelindividualhairs
beingtreated,whichislikeamildpinprick,andaslightwarmingofthearea.
Ifyoufeelanydiscomfortorsorenessthesettingmaybetoohigh.
• Inbuiltsafetyfeaturesprotecttheeyebeingexposedtothelaser,however,
neveraimtheWandatorneareyes.
• DoNOTusenearflammablematerials.
• Keeptheproductoutofreachofchildrenandpets.
• ReflectionHazard:Pleaseremovealljewelleryinthevicinityofthetreatment
areabeforeuse.
• Whennotinuse,storethekeyresponsiblyinasafeplaceawayfromchildren.
• Donottreatthesamehairrepeatedlyinanyonesession.
• Donotuseafterdrinkingalcoholorifyouarefeelingunwellorfatigued.
• Donottreatthefollowingareas:tattoos,permanentmake-up,pimples,warts,
haironblackspotsormoles,darkfreckles,skindisease,birthmarks,burns,
lips,nipples, genitaloranalareas,eczema,eyelashes,eyebrows, nearthe
eyes,nasalorearhair.
 Thisis asensitivelaserscanningproduct.Careshould betakento avoid
damagetothemechanismintheWand.
 Thisapplianceisnotintendedforusebypersons with reducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
they have been given supervision or instruction concerning use of the
appliancebyapersonresponsiblefortheirsafety.
PRECAUTIONS
 DoNOTdismantleorrepair.Ifyouhaveanyproblemsusingtheproduct,
contactourCustomerCareDepartment.
• Misuseoftheunitcancauseharm.
• DoNOToverrideanysafetyfeaturesoropentheunitorwand.
• OnlyusethisproductwiththeMainsAdaptersupplied.
• KeepWandawayfromstrongelectromagneticfieldsandmagnetsduringuse.
PATCHTEST
IMPORTANT:24hoursbeforetreatmentitisveryimportanttodoapatchtest.
Thepatchtestwillconfirmthemaximumpowerlevelforyourskintype.Eacharea
tobetreatedmustbecheckedasskincolourcanvary.Pleaserefertothe‘PATCH
TEST’sectionintheInformationGuideandontheDVDforinstructions.
Aslightrednessmayoccur,butnotalways,withinanhouroftreatment.This
localisedrednessiscausedbythedestructionofthehairfolliclesandisquite
normal.However,ifanyrednessremainsafter24hoursthiswouldindicatethe
powerlevelselectedwastoohighforyourskintype.
GETTINGSTA RTED
Please ensure you read the Information Guide and understand the
Warnings’ and ‘Product Safetysections before proceeding.
• Shavetheareatobetreated.Thisensuresthatthelasergoesdirectly
tothehairrootandavoidshairburningonthesurface.
• Removealljewelleryinthevicinityofthetreatmentarea.
• Pleaseensureyouhavepatchtestedtheareatobetreated24hours
prior to treatment.
STEP 1
ConnectMainsAdapterintotheDCPowerSocket at
thebackoftheunitandplugintotheMains.
STEP2
Unlock with Key to turn on. The light around the
Keyswitchwillflashgreen.
STEP 3
Enterthe“SECURITYBUTTONSEQUENCE”.
You will find the Security Button Sequence in the
Information Guide.
ThegreenlightaroundtheKeyswitchwillfullyilluminate.
Thelightsaroundthex60SCAN,x20SCANandSINGLE
buttonswillflashbluereadyforselection.Thebottom
PowerLevelIndicatorlightwillilluminate.
STEP4
Usethe+/-buttonstoselectthecorrectpowerlevel
foryourskintype.Refertothe‘PatchTest’sectionof
theInformationGuideforskintypes.
Each time the power setting is adjusted, you will
need to reselect x60 SCAN, x20 SCAN or SINGLE
modetocontinue.
Note: If no buttonsare pressedafter20 minutestheUnit will enterenergy
savingmode. The orangelight will flashand power level1will remainon.
TorestartturnkeyoffandbackonagainandstartatStep3.
ADDITIONALINFORMATION
STEP 8
Turn the Keyswitch anticlockwise to lock the unit.
RemovetheKeytoasafeplaceawayfromchildren.
Note: Ifyouexperienceunexpectedbehaviourofthisproductthenitispossible
someexternalelectromagneticinterferenceisresponsiblee.g.electricmotors/
loudspeakersetc. Youshould removethis sourceandrestarttheproductto
restorefulloperation.Atnotimewillthelaserfireunintentionally.
SINGLEHAIRTREATM ENT
Youcanopttotreatsinglehairsusing
theSINGLEmode.
Press the ‘SINGLE button once.
TheSINGLEbuttonwillilluminateblue.
The orange light on the Wand
willilluminate.
FollowthesameprocedureforSCANtreatmentfromStep6,butthistime
pressing the SINGLE button.
In SINGLEmode,thebluelight aroundthe SINGLE
buttonwillflash.
Referto‘TreatmentArea’section,SINGLEmode.
SECURITY
BUTTON
SEQUENCE”
TREATM ENTAREA
Asaguidetothetreatmentarea,asmallindentationmarkwillbeleftby
pressingthe Wanddown ontheskin.Inx60SCANmode,overlapping
theindentationmarkslightlywhenmovingtheWandineachdirectionwill
ensureeffectivecoverage.Inx20SCANmode,overlaptheindentation
markbyhalf.
SCANmodessequentiallytargetsinglehairsineachtreatment.
SINGLEmodeisfortreatingindividualhairs.Thetreatmentareaisinthe
centreoftheindentationguideandmeasures1mmx1mm.
SCANHAIRTREATMENT
STEP 5
Press the x60 SCAN button once. The
blue light around the button will fully
illuminate.Theorangelightonthewand
willilluminate.
Alternatively,pressthex20SCANbuttononce.
STEP6
Placethewandontheskinovertheareayouwishtotreat,
ensuringtheTouchPinsareincontactwiththeskin.
TheorangelightwillturnOFFandthewhite‘ready’light
willturnON.
The blue lightsaroundtheSCANbuttonwill rotate to
indicatetreatmentisreadytostart.
STEP 7
Press and HOLD theLaser Button on the top of the
wandtostartlasertreatment.
The white light will flash on and off to indicate laser
treatmentisinprogressandtheunitwillbeeprepeatedly
(thiscanbemuted).Youwillnotbeabletoseethelaser.
Youmay feel individualhairs being treated, which is
likeamildpinprick,andaslightwarmingofthearea
beingtreated.
Whenthelaser treatmentceases,theorange lightwill
comebackon.Youcannowmoveontothenextareaof
hairstobetreated.
Whenmovingthewandtothenextareaofhairstobe
treatedtheTouchPinsmust be removedbrieflyfrom
theskin.
Refertoscanmodesin‘treatmentarea’section.
IMPORTANTNOTES - please read carefully
• DoNOTmovethewandduringtreatment.Youmaynoticethewandbecomes
warmduringusethisisquitenormal.
• IfcontactislostbetweentheTouchPinsandskinduringtreatment,thewand’s
orangelightwillcomeon.Treatmentwillresumewhencontactismadeagain.
• Foryoursafety,ifthewandisnotpositionedcorrectlyontheskinsurfacefor
treatment,thewhiteandorangelightswillflashalternatelyandoperationof
thelaserwillbedisabled.
Sometimesyou cansmell faint burningor even see a very, small line of
smokeasthehairistreated.
 Successfullytreatedhairsdonotalways falloutimmediately,butareshed
over time as they are released from the hair follicle, light rubbing can
encouragethis.
• Youmayfeela‘pinprick’sensationduringtreatment.Anylocalisedrednessafter
treatmentiscausedbythedestructionofthehairfolliclesandisquitenormal.If
anyrednessremainsafter24hoursthiswouldindicatethepowerlevelselected
wastoohighforyourskintype.Pleaserefertothe‘PatchTest’sectioninthe
InformationGuide.Anylongerlastingrednesswillalsodisappear.
L A S E R  H AI R T R EA TM E N T
1
2
5
8
7
3
4
PresstheMUTEbuttononthebackoftheUnittoturn
offtheBeepnoises.Pressagaintoturnbackon.
Note: Thisdoesn’tturnoffwarningbleeps.
resettingafter‘lockout
If you experience a ‘lockout as indicated by
repeatedflashingofanyofthebluepowerlights,
simplyresetbyturning theunit offusing thekey,
waiting5secondsandturningtheunitonagain.
cleaninglaseraperture
Periodically check whether there are any smoke
deposits on the Laser Aperture. A build up of
depositswillaffecttheefficiencyofthelaser.Ifyou
noticeanydeposits,switchtheunitOFFandunplug
themainsadapter.Thensimplycleanwithalintfree
clothorcottonbud,ensuringnofibresareleftinthe
LaserAperture.
x60 SCANmode
x20 modeSCAN
SINGLEmode
Rio,Dezac,SalonLaserScanningHairRemoverx60andLaserSafeTechnologyaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2011anufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
Overlapbyathird
Overlapbyhalf
treatmentarea
indentationmark
treatmentarea
indentationmark
treatmentarea
indentationmark
1-IN-LAHC5-UK/1.2
instructions
b
e
f
g
h
i
k
j
l m
c
a
d
n
o
p
q
r
s
COMPONENTS
a. Mains Adapter
b. Keys
c. DC Power Socket
d. Mute Button
e. Keyswitch
f. Power Level Indicator
g. Power Increase Button (+)
h. Power Decrease Button (-)
i. x60 SCAN button
j. x20 SCAN button
k. SINGLE button
l. Hand-held Wand
m. Laser Button
n. Orange Light
o. White Light
p. Touch Pins
q. Laser Aperture
r. Indentation Guide
s. Front Face
laseraperture
6


Specyfikacje produktu

Marka: Rio
Kategoria: urządzenie do usuwania włosów
Model: Scanning Laser X60
Kolor produktu: Biały
Szerokość opakowania: 240 mm
Wysokość opakowania: 290 mm
Głębokość opakowania: 85 mm
Technologia usuwania włosów: Laser
Końcówka do ciała: Tak
Regulowana intensywność: Tak
Liczba poziomów intensywności: 5
Precyzyjna końcówka (do twarzy): Tak

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Rio Scanning Laser X60, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje urządzenie do usuwania włosów Rio

Rio

Rio LAHR2 Instrukcja

26 Czerwca 2024
Rio

Rio CNHR2 Instrukcja

26 Czerwca 2024
Rio

Rio IPHR Instrukcja

26 Czerwca 2024
Rio

Rio LAHC2 Instrukcja

26 Czerwca 2024
Rio

Rio LATW Instrukcja

26 Czerwca 2024

Instrukcje urządzenie do usuwania włosów

Najnowsze instrukcje dla urządzenie do usuwania włosów