Instrukcja obsługi Rio CNHR2

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Rio CNHR2 (2 stron) w kategorii urządzenie do usuwania włosów. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/2
instructions
ELECTROLYSIS
HAIR REMOVER
Rio, Dezac and Electrolysis Hair Remover™
are trademarks of The Dezac Group Ltd
© The Dezac Group Ltd 2012
PO Box 17, Cheltenham Spa, England GL53 7ET
www.riobeauty.com
Using micro current technology the Electrolysis Hair Remover
destroys the hair root and papilla to prevent future hair growth.
The micro current changes the pH in the hair follicle to alkaline
which then starts to attack the hair root and papilla cells (it is
these cells which are responsible for hair growth). This action
continues for sometime after the treatment is complete and
the hair has been removed.
It is not always possible to kill all of the papilla cells in a single
treatment and in these situations the hair may regrow. If it does
regrow it is generally much finer and lighter than previously.
Successive treatments will kill the papilla cells giving a
permanent result. You may use your normal epilation
methods in between treatments.
The destruction of the hair root cells continues for some
time after the treatment has finished. It makes no difference
whether you remove the hair immediately or not.
If there is a particularly stubborn hair, an additional treatment
or longer treatment time may be required.
As with all hair removal treatments it is recommended that
the area you have treated is washed with cool water and a
mild antiseptic cream applied.
TIPS
          
detect the conductive gel.
          
battery power is low and it needs replacing.
         
The use of a good quality, leak-proof alkaline battery
is recommended.
             
the battery or unplug from the mains.
          
power adapter, which plugs into the adapter socket on
the side. To order please call the Customer Careline.
 
         
         
on the console unit and do not use them for any other
purpose than intended.
          
cloth, the console unit can also be wiped over.
1. Console
   
3. Treatment indicator
(AMBER)
4. Control dial
5. Treatment complete
 
6. Wand output socket
7. Power adapter socket
(optional extra available
from the Customer Careline)
8. Tweezer Socket
 
10. Conductive gel
  
YOUR ELECTROLYSIS
HAIR REMOVER
C O N D U C T I V E G E L
pr ofessiona l range
B O D Y C A R E
B A T T E R Y 9 V P P 3
1
9
0
!
8
5
7
 
Problem Fault/Cause emedyr
Amber treatment
light does not

and console
bleeps.
Good contact
with the hair
is not being
maintained or
your finger is not
touching tweezer
button.
Check tweezers
are connected
Ensure you are
using gel.
Grasp hair at
skin level.
The amber light
has gone out and
the console is
bleeping.
The contact
with the hair or
tweezer button
has been lost.
If the contact is not
re-established
within three
seconds the
treatment timer will
assume you have
moved onto a new
hair and restart
the treatment from
the beginning.
Grasp hair
at skin level.
The console is
bleeping and the
power light is
flashing.
Console left on -
and not used.
Turn the
console off.
Console is
bleeping
constantly.
Low Battery. Replace battery.
The hair is
difficult to
remove.
More than a
single treatment
is required to kill
this hair.
If there is a lot
of resistance
an additional
treatment or longer
treatment time of
the same hair
may be required
Hair regrows.
It is not always
possible to kill
all of the papilla
cells in a single
treatment.
Repeat the
treatment when the
hair grows back.
Use a longer
treatment time.
Redness of skin
after treatment.
This is quite
normal, you may
wish to apply an
antiseptic cream,
however the
redness should
fade within one
or two hours.
Treatment light
on continuously.
Contact is being
maintained
even when the
tweezers are not
in use.
Clean tweezers
with a damp
cloth thoroughly,
removing all traces
of conductive gel.
1-IN-CNHR2-UK / 1.1
2
6
3
4
© The Dezac Group
© The Dezac Group
© The Dezac Group
•Readallinstructionsthoroughlyand
retainforfuturereference.
•Thisapplianceisnotintendedforuse
bypersonswithreducedphysical,
sensoryormentalcapabilities,or
lackofexperienceandknowledge,
unlesstheyhavebeengivensupervision
orinstructionconcerninguseofthe
appliancebyapersonresponsiblefor
theirsafety.
•Donottreatthefollowingareas:
pimples,warts,haironblackspots
ormoles,darkfreckles,skindisease,
burns,eczema,oreyelashes.
•Notforuseonorbychildrenunder14
yearsold.Notforuseonorbychildren
between14and17yearsoldwithout
parentalsupervision.
•Donotuseafterdrinkingalcoholorif
youarefeelingunwellorfatigued.
•Pleaseremovealljewelleryinthe
vicinityofthetreatmentareabeforeuse.
•Therearenouserserviceableparts
insidetheunitorwand.DoNOT
dissembleorrepair.Ifyouhaveany
problemsusingtheproduct,contact
ourCustomerCareDepartment.
STEP 1
Release the clip to open the battery cover.
STEP 2
Connect a PP3 alkaline battery and
replace battery cover ensuring it is shut
firmly in place.
HAIR REMOVAL
STEP 1
Wash area to be treated with warm water
and mild soap. This will remove any
excess oil from the skin.
STEP 2
Check the speed control is on minimum


STEP 3
Turn the Control dial to suit the type of hair
being treated. The treatment time varies
between five and thirty seconds depending
on the setting (see hair treatment chart).
HA IR TREAT MENT CH ART
STEP 4
Apply a small amount of conductive gel to
the hairs which are to be treated OR put a
blob of gel on the skin, into which you can
dip the tweezers before taking hold of the
individual hair.
1
2
STEP 5
Take hold of the hair at the point where it
meets the skin.
Only apply a gentle pressure on the
      
(see step 7). You must use a bare finger on
the tweezer button. Do not wear a glove.
STEP 6
The amber treatment light will start flashing,
indicating the treatment is in progress.
If the amber light does not come on, check
the tweezers are plugged in and that you
are making a good contact with the hair at
the point where it meets the skin.
STEP 7
When the treatment is complete you will
hear a short bleep and the green treatment
complete indicator will illuminate. The
hair can now be removed by increasing
the pressure on the tweezer button to
pluck the hair out of the hair follicle.
(The unit will then automatically reset itself
to start again).
STEP 8
If contact with the hair is broken
during treatment the amber treatment
light will go out and the unit will bleep
three times. If the contact is not
re-established within three seconds the
treatment timer will assume you have
moved onto a fresh hair and will restart the
treatment programme.
1
3
4
5
Gel
6
8
7
Hair Type Dial Setting Treatment Time

eg lip 2 - 5 5 - 15 seconds
Medium hair
eg eyebrow  15 - 25 seconds
Thick hair
eg bikini line 10 - 13 25 - 30 seconds
BA T E RYT 9 V PP3
2
CUSTOMER CARE
If you have any questions, please call our Customer
Careline on: or email us at: +44 (0) 1242 702345
online@riobeauty.com
To register your two year guarantee online visit:
www.riobeauty.co.uk/warranty.html
DISPOSAL
The Waste of Electrical and Electronic Equipment
      
place to recycle products using best available
recovery and recycling techniques to minimise the
impact on the environment, treat any hazardous
substances and avoid the increasing landfill.
The product is classed as Electrical or Electronic equipment
so please ensure that at the end of the life of this product
it is disposed of in the correct manner in accordance with

household waste.
© The Dezac Group
© The Dezac Group
© The Dezac Group

Specyfikacje produktu

Marka: Rio
Kategoria: urządzenie do usuwania włosów
Model: CNHR2
Kolor produktu: Biały
Wysokość produktu: 75 mm
Szerokość produktu: 150 mm
Głębokość produktu: 150 mm
Waga produktu: 300 g
Szerokość opakowania: 205 mm
Wysokość opakowania: 243 mm
Głębokość opakowania: 113 mm
Technologia baterii: Alkaliczny
Waga wraz z opakowaniem: 629 g
Liczba baterii: 1
Ładowanie akumulatora: Tak
Baterie w zestawie: Tak
Podświetlenie: Nie
Zmywalny: Nie
Napięcie baterii: 9 V
Zasilany baterią: Tak
Przycinarka: Nie
Funkcje masażu: Nie
Mokry & Suchy: Nie
Liczba szczypiec: - pęset(y)
Chłodzenie: Nie
Golarka: Nie
Ruchoma końcówka: Nie
Dołączona końcówka do twarzy: Tak

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Rio CNHR2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje urządzenie do usuwania włosów Rio

Rio

Rio LAHR2 Instrukcja

26 Czerwca 2024
Rio

Rio CNHR2 Instrukcja

26 Czerwca 2024
Rio

Rio IPHR Instrukcja

26 Czerwca 2024
Rio

Rio LAHC2 Instrukcja

26 Czerwca 2024
Rio

Rio LATW Instrukcja

26 Czerwca 2024

Instrukcje urządzenie do usuwania włosów

Najnowsze instrukcje dla urządzenie do usuwania włosów