S P E C I F I C A T I O N
PREPARING THE UNIT FOR USE
OPERATING INSTRUCTION
Automatic Ignition (Piezo Magnetic)
MODEL :
RI-511 A
RI-602 Di
RI-602 HTB
Model
R -51I 1 A
R -602I Di
R -602I HTB
Dimension
Height Width Depth Net Weight Gas Consumption / h Gas Inlet Connection
140 mm 280 mm 380 mm 2.1 Kg
LPG
3.80 kW
4.60 kW
NG
Rubber Hose
3/8
141 mm
141 mm
702 mm
702 mm
388 mm
388 mm
4.4 Kg
4.5 Kg 7.60 kW
4.30 kW
8.70 kW
4.80 kW
(Figure No.1) (Figure No. 2)
15 cm 15 cm
100cm
15 cm
(Figure No.3)
Name of Part :
1. Top Plate
2. Main Burner
3. Pan Support
4. Simmer Burner
5. Ignition Knob
6. Dragon Burner (RI-602Di)
1. Check to ensure that all parts of the gas cooker are complete.
2. A minimum clearance is 15 cm from the side / back wall and 100 cm
from the ceiling is required when installing the gas cooker. The gas
cooker shall be placed in a good ventilated room. (Figure No. 1).
3. Using a screwdriver affix the rubber legs with the provided screw
into the designated hole on the gas cooker's bottom. (Figure No. 2)
4. Insert the ignition knob in its correct position by pushing it inward
firmly.(Figure No. 3).
5. Place the Simmer Burner Head onto the gas pipe. (Only for RI-511 A,
RI-602 HTB)
6. Place the pan Support that are common on the right and the left.
(Figure No.3).
7. Push the rubber hose on the gas pipe and regulator as far as it will
go. Secure the hose using a hose clamp.
8. Open the main valve on the gas cylinder. In the event of gas leak,
close the main valve immediately and open the windows in the
room to allow the gas to escape.
Safe and easy to operate, the burners will ignite automatically when the control knobs are pushed and turned in counter-clockwise
direction.For best results from your Rinnai Gas Cooker, Please read the instruction given below carefully prior to operating the unit.
1
3
5
42
3
6
1
6
5
3
1
42
5
4 2
RI-511 A
RI-602 Di RI-602 HTB
Ignition Knob
Pan Support
Simmer Burner Head
OPERATING THE UNIT MAINTENANCE AND CARE
ATTENTION
(Figure No. 5)
* Push in fully
OFF
* Turn Counter
clock-wise
MAX FLAME
SIMMER
MINIMUM
SIMMER
(Figure No. 7) (Figure No. 6)
Flame does
not ignite
Main Gas Stopcock is not turned on
Air remains in the gas piping
Bend or crushed rubber tubing
Piezo electrode or insular is dirty
The gas cooker out of order
Cracks or holes in the rubber tubing
Rubber tubing is not connected
properly
Regulator leakage
The gas cooker out of order
Smell of gas
Turn off the gas cooker once and than turn it in fully
Straighten it, or replace it
Clean it with dry cloth
Request to AFTER SALES SERVICE for repair
Replace it with a new one
Connect the rubber tubing properly
Replace it with a new one
Request to AFTER SALES SERVICE for repair
Flame abnormal
Air supply is not properly adjusted
The gas cooker out of order Request to
AFTER SALES SERVICE for repair
Clean the clogged part
Fix burner body properly
TROUBLE CAUSE SOLUTION
TROUBLE SHOOTING GUIDE
Adjust is properly (See Page 2 Fig.6)
Burner is not fitted properly
Flame outlet of burner is clogged
2
1. Igniting the burner and adjusting the flame.
* For model RI-511 A, RI-602 HTB.
*)Open the valve on the cylinder
Operate the Burner with its double ring burner and "Max",
"Simmer" and "Minimum Simmer" Flame selector as follows :
Maximum Flame
Push The RHS Knob in fully and turn counter clockwise to
"MAX" in this position both Outer and inner burners will burn
fully.
Flame is adjustable between the "MAX" and "OFF" position by
slowly turning the knob to the "OFF" position (Figure No. 5)
Simmer Flame
Turn the knob to the left on the "Simmer" direction the outer
burner will be switched off and only the Smaller inner burner
(Simmer) will function.
Minimum Simmer Flame
Turn the knob to the left on the "Minimum Simmer", Where
the burner small will burn smaller.
2. If no flame, turn back the knob to "OFF" position, repeat the
ignition procedure as above.
3. Air Control
For good flame, turn Damper upward or downward until a blue-
colored flame is obtained. (Figure No. 6)
Ø
* For model RI-602 Di.
*)Open the valve on the cylinder.
Maximum Flame
ØPush the knob in fully and turn it counter clockwise to “MAX”
position, where the burner will burn fully.
Minimum Flame
ØFrom “MAX” position turn the knob to the left on “MIN”
position, where the burner will burn smaller.
ØFlame is adjustable between the “MAX” and “OFF” position.
(Figure No. 4)
1.Using a brush, to clean the Burner Head and Burner Top
surface of any dust adhering to these part.
2. Wipe clean the pan support, and other Stainless Steel Part
with a small amount of Soapy Water. Don't use the alcohol or
gasoline, because can damaged the part.
3. Clean the Electrodes as dust adhering to these parts may
prevent a good ignition. (Figure No. 7)
1.Keep away any flammable material / liquid from the gas
cooker.
2.The gas cooker shall be placed in a good ventilated room.
3. Never use one single rubber hose for two gas cooker.
4. Do not place any objects that may easily be blown away by
the wind on the gas cooker.
5. In the event of gas leak, do not switch on any fan/ lighter.
6. Do not use any small cooking utensil that may cover the
burner flame and thereby extinguishing it.
7. Do not use any large cooking covering the entire gas cooker
surface.
8. Replace any damage / cracked rubber hose immediately.
9. Don't touch the gas cooker immediately after cooking.
10.Take care that no boiling water spills onto the gas burner's
top surface.
11.Do not use the gas cooker to dry.
12.Do not leave the gas cooker unattended when on.
13.Do not route the rubber hose under the gas cooker.
Repeat ignition operation until all air in the piping is
purged out completely
If trouble occurs, fix it referring to the above table. But if the problem still
remain, or in case a serious malfunction, and if you are doubt, then take the
gas cooker to our for repairing without trying to AFTER SALES SERVICE
repair it your self.
RI52-207-5x01
* Push in fully
MINIMUM
FLAME
OFF
* Turn
Counter-clockwise
ON/MAX FLAME
(Figure No. 4)

Specyfikacje produktu

Marka: Rinnai
Kategoria: piec
Model: RI-602HTB-S
Kolor produktu: Black, Stainless steel
Typ kontroli: obrotowy
Wbudowany wyświetlacz: Nie
Położenie urządzenia: Blat
Wysokość produktu: 141 mm
Szerokość produktu: 702 mm
Głębokość produktu: 380 mm
Waga produktu: 4500 g
Rodzaj płyty grzejnej: Gaz
Rodzaj gazu: Gazu płynny (LPG)
Typ górnej powierzchni: Stal nierdzewna
Liczba palników/stref gotowania: 2 stref(y)
Liczba palników: 2 stref(y)
Liczba płytek elektrycznych: 0 stref(y)
Zapłon elektroniczny: Tak
Przyłącza (prąd): - W
Pozycja panelu sterowania: Przednie
Przyłącza (gaz): - W
Liczba jednocześnie używanych stref grzewczych: 2
Kształt zwykłego palnika/strefy gotowania: Okrągły
Kształt palnika do gotowania na wolnym ogniu/strefy gotowania: Okrągły

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Rinnai RI-602HTB-S, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje piec Rinnai

Instrukcje piec

Najnowsze instrukcje dla piec

Miele

Miele KM 7404 FX Instrukcja

9 Października 2024
Proctor Silex

Proctor Silex 37533 Instrukcja

1 Października 2024
Siemens

Siemens ED651HSB1E Instrukcja

23 Września 2024
Siemens

Siemens ER7EA233HK Instrukcja

23 Września 2024
Siemens

Siemens ER3A6AD70A Instrukcja

22 Września 2024
Atag

Atag HIDD08471EVX Instrukcja

21 Września 2024
GE

GE JGS760FPDS Instrukcja

19 Września 2024
ARC

ARC CI6SE2 Instrukcja

18 Września 2024
ARC

ARC CD7SG1 Instrukcja

18 Września 2024