Instrukcja obsługi Reefe RSF2500

Reefe Pompa wodna RSF2500

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Reefe RSF2500 (3 stron) w kategorii Pompa wodna. Ta instrukcja była pomocna dla 3 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/3
RAMDEX INDUSTRIES 37 Export St Lytton Qld 4178 Ph.: 1300 726 339 ©Copyright 2012 Page of 1 3
REEFE™ SOLAR PUMP USER MANUAL
Model No.: RSF2500
1. OVERVIEW
1) The solar water pump is designed for water features and
waterfalls, and is powered by a solar panel.
2) The solar panel needs to be placed in the sunlight with its
solar cells facing the sun as much as possible, the
performance of the pump depends on the sunlight intensity
and the orientation of the solar panel.
3) The latest DC brushless motor technology is used in the
pump design and manufacturing, so that the pump has high
efficiency and long service life.
4) The pump has a built-in function of dry-run protection. The
dry-run protection function is provided by two sensor points on one side of the pump body (not
visible from outside.-see Figure 1). The pump works if both of the points are submerged in water. If
either or both points emerge out of water, the pump stops working.
2.
COMPONENTS
1) Solar panel with ground spike
2) Pump
3) Hose connection
4) Gland nut (M56 x 2.0mm thread)
5) Spare Impeller (Not pictured)
3. ASSEMBLING
1) Completely unroll the power cable.
2) Attach the hose onto the outlet of the hose connection. The hose connection is suitable for various
hose diameters (inside diameter 25,32 or 38 mm). For fountain nozzle use see above Fountain
Function”.
3) Mount the hose connection to the pump outlet by means of the enclosed gland nut. Via the ball joint,
the angle of the hose connection may be adjusted under water as necessary.
4) Completely immerse the pump into the water.
5) Connect the pump to the solar panel, and ensure the cable connection is tightened correctly.
6) Install the solar panel in garden lawn or soft ground by means of the spike. Adjust the angle to face
the solar panel toward the sun.
7) The solar pump is now ready to operate.
Figure 1
Figure 2
FOUNTAIN FUNCTION
If you wish to use a fountain
nozzle (not supplied) you will
need to connect it using hose
from the hose connection
(part 3 in Figure 2) as the
thread outlet on the pump is a
non-standard thread (M56 x
2.0mm)
RAMDEX INDUSTRIES 37 Export St Lytton Qld 4178 Ph.: 1300 726 339 ©Copyright 2012 Page of 2 3
3. CAUTIONS
1) Any altering of the product itself or changing of the components voids warranty.
2) Do not connect the pump to any AC voltage power directly; it can ONLY
operate on DC voltage power.
3) Operate the pump in water only (never above 40 °C), especially keep it
away from flammable liquids. Do not use in any hazardous areas.
4) All the connectors are protected against reverse polarity as shown in
Figure 3. Don’t insert the plug with reverse polarity by using force.
5) The pump is dry run protected. The pump will automatically stop when
the water level is low.
5. CLEANING AND MAINTENANCE
If the pump starts losing power or stops working after operating for a certain time, please clean the inside
of the pump and any debris on the filter cage.
The pump can be opened by unscrewing the four screws on the four corners of the filter housing bottom.
To clean the pump, disassemble the pump according to Figure 4 and then clean all parts with water.
In the case of a build-up of lime-scale (calcium deposits) use a mild descaling solution,
following the instructions provided for a “shower head”- we recommend RUBBEDIN DESCALE
MAGIC – available from most Hardware’s and Supermarkets.
Be careful not to drop the ceramic shaft while cleaning the impeller as it breaks easily.
6. TROUBLE SHOOTING
Pump does not operate, please check the following possible reasons:
1) Clouds, dust or shade will cause the pump to stop.
2) No connection to the power supply.
3) Impeller is blocked—to clean the pump as described in “
CLEANING AND MAINTENANCE
.
4) Check the water level, ensure the pump is fully submerged in water.
5) If all above are ok, try the spare impeller supplied with the pump.
If pump does operate but there is no water running through the pipework: Clear the
pipework and the filter to make sure there are no blockages.
7.
TECHNICAL DATA AND PUMP CURVE
Performance data is subject to change without notice, ALL
and is subject to the Solar Energy (Sunlight) available.
Peak Power of Solar Panel 25W
Operating voltage 18V
Maximum pump head 2.1m
Maximum flow rate 2480L/H
Cable length 5 M
Figure 3
Figure 4
RAMDEX INDUSTRIES 37 Export St Lytton Qld 4178 Ph.: 1300 726 339 ©Copyright 2012 Page of 3 3
WARNING: Condition of Warranty: This pump MUST NOT be installed in any manner that if it were to leak
that it would cause damage or loss to property or persons. It MUST be installed in a well-ventilated and
drained area. All warranty is void if this condition is not heeded and no liability can be accepted in the
case of damage or loss caused by failing to comply with this condition.
WARNING: Do not attempt to open the sealed Battery unit. Serious bodily harm may occur including
but not limited to blindness and poisoning and death.
SOLAR PUMPS 24 MONTH LIMITED WARRANTY CONDITIONS
1. Warranty covers only motor failure and manufacturing defects within a 24 month period from the original date of purchase for REEFE™ SOLAR PUMPS
purchased and used in mainland Australia.
2. Faults arising due to: - Accidents, misuse, not following these instructions or power surges/spikes/brownouts will not be covered by this warranty
3. Warranty will be void if any tampering or removal of identification labels or electrical cables has occurred, or if pump is moved from the original place of
installation or if any non-genuine parts have been fitted.
4. The costs of loss of livestock, damage to property, consequential losses or injury caused by the misuse or abuse or your installation of this appliance is not
covered by this warranty. Also, consequential losses caused by faults or failure of this product (which are not reasonably foreseeable by RAMDEX
INDUSTRIES to occur) are not covered by this warranty.
5. Faults caused by installation or improper servicing will not be covered. In addition defects stemming from insufficient maintenance are not covered.
6. Warranty is void if this pump is used for pumping anything other than fresh, clean water, or clean saltwater.
7. In the case of pump failure, you must:
a) Check the trouble shooting guide first.
b) Then call RAMDEX on 1300 726 339 and speak to the Warranty Department who will authorize repair or replacement OR you may return to the original
place of purchase for replacement or refund.
8. For any warranty claim to be valid, an original proof of purchase must be supplied, or an acceptable substitute.
9. If an exact replacement is not possible the closest equivalent product will be supplied at Ramdex Industries discretion.
10. This product is guaranteed as fit for the purpose of use as stated on the outer packaging, and NO other use.
11. Condition of Warranty: This pump is not to be used as your sole water supply or for drinking water or for fire-fighting purposes.
12. Condition of Warranty: This pump MUST NOT be installed in any manner that if it were to leak that it would cause damage or loss to property or persons.
It MUST be installed in a well-ventilated and drained area. All warranty is void if this condition is not heeded and no liability can be accepted in the case of
damage or loss caused by failing to comply with this condition.
13. This product is not intended for use by children or infirm persons. It is your responsibility to ensure, by way of supervision or isolation, that children or
other infirm or irresponsible persons are not harmed by this product.
14. All installations must comply with the local Council, Shire, electrical and plumbing regulations in your area.
15. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major failure. If you (the purchaser) do not fall within the meaning of ‘consumer’ in
the Australian Consumer Law some or all of the provisions of the Australian Consumer Law will not apply to you.
©Copyright Ramdex Industries. REEFE® and Ramdex® are Registered Trademarks of Ramdex Industries. Specifications are approximate and subject to
change without notice at Ramdex Industries discretion. Since the methods and conditions of application are beyond our control, Ramdex Industries does not
accept liability for any deficiency in performance resulting from the misuse or abuse of its products, the user must ascertain that the chosen product is
suitable for their purpose. Product may differ to that illustrated due to design improvements. This pump has not been tested for use with potable water.
Conditions apply to all Ramdex Industries product warranties which may be varied at Ramdex Industries discretion.
IMPORTANT NOTE: DO NOT use for anything other than clean, fresh or saltwater.
NOTE:
1. Save Power and the Environment refers to the fact that this product does not require mains power to operate. Note that this product has not been
independently tested to verify the savings.
2. Performance figures are for the maximum performance in full mid-day summer sunlight and will vary according to the Solar Energy available; the pump
may not operate at all when the Sun is obscured by clouds or dust. This Solar Pump does not operate during the night, except for Battery Back-up
versions.

Specyfikacje produktu

Marka: Reefe
Kategoria: Pompa wodna
Model: RSF2500

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Reefe RSF2500, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Pompa wodna Reefe

Reefe

Reefe RSF2500 Instrukcja

30 Września 2024
Reefe

Reefe PRJ100E Instrukcja

30 Września 2024

Instrukcje Pompa wodna

Najnowsze instrukcje dla Pompa wodna

Dimplex

Dimplex WI 22 TE Instrukcja

11 Października 2024
DAB

DAB FEKA Instrukcja

9 Października 2024
Einhell

Einhell BG-DP 3730 Instrukcja

9 Października 2024
Einhell

Einhell Royal HW 811 Instrukcja

9 Października 2024
Hayward

Hayward S240SLETL Instrukcja

9 Października 2024
Anova

Anova BE1450ASC Instrukcja

8 Października 2024
Anova

Anova BA2C10 Instrukcja

8 Października 2024
Einhell

Einhell RG-GP 1139 Instrukcja

8 Października 2024