Instrukcja obsługi Raytec Spartan

Raytec Ulga Spartan

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Raytec Spartan (16 stron) w kategorii Ulga. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/16
SPARTAN
Floodlight Range Installation Guide
CML13ATEX3007 IEC Ex CML14.0001
This installation guide provides instructions for installing the Infra-Red and
White-Light SPARTAN SPX series of explosion protected oodlights.
Text in Bold is specic for emergency variants
Overview
1 Safety Instructions
2 Installation
3 Maintenance
4 Technical Specication
5 Trouble Shooting
The SPARTAN series of explosion protected oodlights are specialist devices,
certied for use in specic operating environments.
The units must be installed in accordance with these instructions, must be correctly
certied for the specic operating environment and must be installed by suitably
qualied personnel.
Emergency oodlights will require the fuse to be reconnected upon
installation and the oodlight subjected to three 24 hour charge/discharge
cycles to bring the battery up to peak capacity.
If you have any queries about the installation or the certication of the unit – please
contact Raytec for immediate assistance and advice.
910-M-0094-2
Important information
2www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
1. Safety instructions
1. Read this leaet carefully before commencing to install the SPARTAN unit and
retain it for future use. Installation can only be carried out by suitably qualied
personnel.
2. Check the certication to ensure that the mains supply and the ambient
temperature present is suitable for the unit being installed.
3. If the SPARTAN unit is to be installed in areas of high vibration, please consult
with Raytec.
4. The SPARTAN unit housing is constructed from marine grade aluminium and
toughened glass. The end user must ensure that these materials are suitable
for the environment the SPARTAN unit will be installed in; Zone 1 and Zone 2
Hazardous areas.
5. Check certication nameplate on side of oodlight to ascertain type of threaded
cable entry on the luminaire. Select suitably certied ATEX/IEC Ex cable glands
and stopper plugs, these must be parallel thread, have a minium of 5 full thread
engagement and be of a medium/ne tolerance to ISO965-1 and ISO965-3. The
cable entry devices selected must maintain the IP rating of the luminaire
6. The incoming mains cable should not exceed a temperature rise of 20 C above °
the ambient conditions; select suitable cable.
!
Install in a well
ventilated area
Do not continually
stare at lamp
Isolate mains before
removing cover
1.5m
3www.rayteccctv.comUK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
2. Installation
Mounting SPARTAN Unit
1. To meet the requirements of certication a MINIMUM of 2 xing points must be
used, the xing points must be suitable for the conditions of use.
Spartan 12 Floodlight
Spartan 24 (Emergency Variant Shown)


Specyfikacje produktu

Marka: Raytec
Kategoria: Ulga
Model: Spartan

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Raytec Spartan, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Ulga Raytec

Raytec

Raytec Spartan Instrukcja

1 Października 2024

Instrukcje Ulga

Najnowsze instrukcje dla Ulga

Goobay

Goobay 30780 Instrukcja

15 Października 2024
QTX

QTX DM-X12 Instrukcja

15 Października 2024
Livarno

Livarno IAN 94799 Instrukcja

15 Października 2024
Astro

Astro Denia Instrukcja

13 Października 2024
AFX

AFX Grace GRCP07CBBK Instrukcja

12 Października 2024
AFX

AFX Point PNTP0107L30D1BK Instrukcja

12 Października 2024
Neewer

Neewer TL97C Instrukcja

9 Października 2024
Neewer

Neewer SRP18C Instrukcja

9 Października 2024
Ikea

Ikea STRÅLA 005.824.56 Instrukcja

9 Października 2024
Ikea

Ikea STRÅLA 705.829.38 Instrukcja

9 Października 2024