1. Please close windows and doors for
accurate measurement.
2. Connect the 12V adapter at Radon
Eye, it is automatically started. Place the
Radon Eye on the table.
4. When the measured value is greater
than the 4pCi/l (148Bq/㎥) safety
threshold, an alarm will sound. Just
open the window for ventilation longer
than 10 minutes.
5. You can use Smartphone App to
manage data and setting. Please refer to
the Smartphone App Guide.
6. Indoor radon level is generally increased in the dawn. Also, it is
highest in the winter season.
3. A measured value is displayed every 10min. Please wait just 1 hour
for a more accurate value. With other economic models like the C or
P device, it takes 24~48 hours to approach a valid reading.
App Guide
Getting Started
Variation of Radon concentration during days
Indoor
Radon
Concentration
dawn
daytime daytime
night
Variation of Radon concentration during a year
Spring Summer Autumn Winter
Indoor
Radon
Concentration
Measurement speed
Radon Eye
How Fast Radon Eye!
C_device
P_device
Measured value
12h 24h 36h 48h
Ref. value
1h
Input in search box at the your Radon Eye”
smartphone’s App store or Google Play.
1. Search Application & Download 4. LOG -> Data Load & Save
Radon Eye Quick Guide
Smart Radon Detector
New Excellent Technology certified
from Republic of Korea
2. Download Radon Eye Application
Download and install application.
Radon Eye
FTLAB
3. Connect & Menu
1
Saved Log file List
- To bring the saved file
4
Configuration Setting
- Unit setting
- Alarm ON/OFF setting
- Alarm interval setting
3
- Please connect
Radon Eye
- Current measurement
value is displayed.
- Press the set menu.
2
3
2
1
·
Please use Bluetooth 4.0 & Android 4.3 or higher versions.
· Bluetooth working distance : < 10meter
· Please avoid vibration or shock during measurement.
· Radon Eye can be operated by a power bank and step-up cable.
Please refer to the battery usage of the operation manual.
- CLEAR : Delete all data
- DATA LOAD : To bring data on smartphones from Radon Eye
- SAVE AS : To Save data in smartphones.
location of Saved file
iPhone PC Connecting : iTunes -> App -> File-sharing -> RadonEye click!
Android Smart appliances : File Manager -> Radon FTLab click!
Q1 : Why we have to measure Radon level in our home?
A1 : Recently, non-smoking lung cancer patients have been increased. The ultra-fine dust, second-
hand smoke and Radon are the main cause. In these three cause, Radon is the most dangerous.
Because Radon is a colorless, odorless and tasteless, so it beyond the human senses. According to
the report of the US Environmental Protection Agency, EPA, in the United States, lung cancer
deaths caused by Radon are actually a lot more than the deaths caused by drunk driving.
Q2 : Why is the real time measurement important?
A2 : Radon level is usually highest in the dawn when everyone slept deeply. In the middle of a day,
when children go to school and their parents go to the work that no one in the house, Radon level
is the lowest. So the average of Radon level of all day would be meaningless. And If you neglect
ventilation even for a few days during the winter time, Radon level can be as high as several times
more than usual although radon levels are usually the lower house. This is the main reason for
measuring radon in real time. And when the high Radon level would be detected in your house by
Radon sensor, it is recommended to equip the facilities that can immediately mitigate the radon
level.
Q3 : What should I do when the high level of Radon in my house?
A3 : First, it is important ventilation. If your home Radon levels are high, you should have a vent at
least three times a day and slightly open the windows usual. When the problem is serious, you
must request the help of Radon specialists.
Q4 : If ventilation condition of the house is not good, does
Radon concentration is increased endlessly?
A4 : No, Radon level would be converged to a certain level within a week because the Radon
half-life of 3.8 days.
Q5 : Does Radon also present in the water?
A5 : Yes. Radon could be dissolved in water. So Radon could exist in groundwater. However,
drinking groundwater containing Radon is not a big problem if the radon level would be very high.
Because alpha particles emitted from the alpha decay of radon, is very weak for penetration
power. Therefore it does not significantly affect the digestive surface of the human. So Radon is
primarily caused problems when entering the lung through the respiratory a gaseous state.
Q&A
This Radon gas will cause lung cancer (US EPA report)
In particular cause lethal danger to young children and pregnant women.
Radon is primarily occurring in the soil. However, it may occur in building
materials. Therefore, care should be taken in high-rise apartments.
(VOC will be gone after 2~3 year, but radon is forever)
The houses with basements, schools, underground facility are the place of
highest risk! Moreover, the higher radon concentration is at dawn that
most people sleep.
If it exceeds the reference value 4pCi/l (148 Bq/㎥) to 10 minutes or more
to be ventilated,
Dangerous Radioactive gas. It is a colorless, odorless, and tasteless gas and therefore
not detectable by human senses alone. It’s density is 8 times higher than air, so it
could be easily high concentration state in the basement. Radon in indoor air is very
small amount but always present in our surroundings like CO2, O2.
What is RADON?
Manufacturer : FTLAB | www.radonftlab.com sales@ftlab.kr
• Sensor Type : pulsed ion chamber
• First reliable data out : < 1hour
• Data display interval : 10min update (1hour moving average)
• Sensitivity : 0.5cpm/pCi/l (1.35cpm/100Bq/㎥)
• Operating range : 10℃ ~ 40℃, RH < 90%
• Range : 0.1 ~ 99.99 pCi/l (1~3700Bq/㎥)
• Precision : < 10% at 10pCi/l (370Bq/㎥)
• Accuracy : < ±10% (min. error < ±0.5pCi/l (±15Bq/㎥))
• Power consumption : DC 12 ± 0.1V, 65mA (12V DC adapter)
• Size : Φ80(mm) x 120(mm) , 240g
• Data communication : Bluetooth LE (Android / IOS)
• Data log : max 1year (1hour step)
• Display : 0.96 inch OLED
(All test data have been measured at 25℃ ± 2℃)
SPECIFICATION DESCRIPTIONS
Radon Eye Quick Guide
Smart Radon Detector
New Excellent Technology certified
from Republic of Korea
RD200 is a Smart Radon Detector made in South Korea which is the home country
of Samsung Galaxy Smartphone. The RD200 has 20 times higher sensitivity than
the other handy radon detectors. Because the RD200 has the dual structured
pulsed-ionization chamber system and highly accurate detection circuit designed
by FTLab’s own technology. A time for the first reliable data display is just <1 hour,
so no longer need to wait a long time, 24~48hours. Also, it offers huge conve-
nience for data logger, graph display, alarm setting using Bluetooth function with
Smartphone.
* The minimum measuring time refers to the time it takes to reach a reliable measured value.
The shorter means the faster the response speed of the measuring equipment.
* This chart is reported just for reference and may differ from the true.
If is not responsible for regal issues resulting from the use of this data.


Specyfikacje produktu

Marka: RadonTec
Kategoria: Niesklasyfikowane
Model: RD200

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z RadonTec RD200, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane RadonTec

RadonTec

RadonTec RD200P2 Instrukcja

20 Września 2024
RadonTec

RadonTec RD200 Instrukcja

18 Września 2024

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Stihl

Stihl HT 70 Instrukcja

15 Października 2024
Ernesto

Ernesto H14270 Instrukcja

15 Października 2024
Uniden

Uniden BT MIC KIT Instrukcja

15 Października 2024
Vaude

Vaude Omnis Bike 26 Instrukcja

15 Października 2024
ART

ART ProChannel II Instrukcja

15 Października 2024
Aukey

Aukey DR02J Instrukcja

15 Października 2024
Master Lock

Master Lock 653EURD Instrukcja

15 Października 2024
Roland

Roland FR-18 Diatonic Instrukcja

15 Października 2024