STL110 Installation Manual
STL110
Specifications:
Switching Capacity: 8 amps
Voltage: 120 volts
1000 watts Incandescent
500 watts Fluorescent
Detection Pattern: 50’ x 110˚
Time Adjustment: 5 seconds to 12 minutes
Power Consumption: 1 watt
Surge protection: I. E.C. specs
UL Listing: Raintight Photoelectric Switch
STL110H
STL110HB
STEALTH
STL110R
TURN OFF ALL POWER AT
CIRCUIT BREAKE FUSE PANEL.R/
Read entire Installation Manual
before proceeding.
All wiring should comply with
local electrical codes and requires
a qualified electrician.
The total lighting load connected
to Stealth must not exceed 8 amps
(1000 watts incandescent or quartz,
500 watts fluorescent). To switch
more wattage an electrician can
install a relay.
• •
Line Carrier Remote Control
Systems such as X-10, Leviton or
Radio Shack are incompatible with
sensors and cause false activations.
• •
Do not install sensors on a
circuit that feeds motor loads
like kitchen appliances, HVAC
equipment, washer/dryer, or garage
door openers.
Sensor must be below and as far
as possible away from lights.
Sensor functions best when the
direction of expected movement
is across its detection pattern, not
towards the sensor.
Mount 6–12 feet high for
optimum range and detection.
STL110 floodlight kits come pre-
wired and assembled on the RAB
CU4 EZ plate, allowing for mounting
on round, rectangular or octagonal
surface or recessed boxes.
Cautions: Mounting Plate:
Bar
Screws
Metal Mounting
Plate
CU4 EZ
Plate
Universal
Mounting Bar
Gasket
O-RingGasket
Insert
close-up
plug in
unused
hole
Finishing
Cap
1
Stealth’s infrared sensor “sees”
small temperature changes caused
by the motion of people or cars
within its protection zone and turns
on lights automatically. It welcomes
visitors and may deter intruders.
How long do the lights stay on?
Lights remain on as long as there
is movement within the protection
zone. Once the zone is vacated
lights can be adjusted to remain
on approximately 5 seconds up to
12 minutes. Since the lights are on
only when needed, and the sensor
uses only one watt the Stealth is
extremely energy efficient.
Can outdoor lights still be turned
on with the light switch?
Yes. Stealth can be controlled by a
conventional indoor switch or circuit
breaker. Lights can be turned on or
off manually at night only.
Manual Override Mode:
(to keep lights on) Flip the switch
twice slowly (off-on-off-on) within
2–3 seconds.
To Resume Automatic Mode:
Flip the switch once (off-on) within
2 seconds. Sensor will reset to
Automatic Mode.
Will Stealth detect animals?
Stealth may detect large animals.
Having animals trigger the sen-
sor can give property a “lived-in”
look. However, you can limit animal
detection by turning down the
sensitivity knob and/or by placing
opaque weatherproof tape on the
lower part of the lens.
How are the Time, Sensitivity and
Photocell adjusted?
Time: Sets the time that lights
will remain on after the detection
zone is vacated from approximately
5 seconds to 12 minutes.
Factory Setting: 5–8 minutes
Sensitivity: Increases or
decreases the responsiveness
and range of the sensor
(Adjusts from 30% to 100%)
Factory Setting: 100%
Photocell: Located behind the
lens. For night only operation, turn
the knob all the way clockwise to
(to the moon symbol). For 24 hour
operation turn the knob all the way
counterclockwise (sun & moon).
Adjust clockwise to have the sensor
come on later at dusk, counter-
clockwise to have it come on earlier.
Factory Setting: Night Only
Control Panel:
How Does the STEALTH Work?
2
SENS PHOTO TIME
Minimum
30%
Maximum
100%
24 Hour
Operation
Night
Operation
5 Sec 12 Min

Specyfikacje produktu

Marka: RAB
Kategoria: detektor ruchu
Model: STL110H

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z RAB STL110H, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje detektor ruchu RAB

RAB

RAB STL110H Instrukcja

23 Września 2024

Instrukcje detektor ruchu

Najnowsze instrukcje dla detektor ruchu

Maxsa

Maxsa 40234 Instrukcja

9 Października 2024
Maxsa

Maxsa 43218 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-233 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-219 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-232 Instrukcja

9 Października 2024
ORNO

ORNO OR-CR-231 Instrukcja

9 Października 2024
JUNG

JUNG BTLC17181244 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182250 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17181255 Instrukcja

8 Października 2024
JUNG

JUNG BTLC17182259 Instrukcja

8 Października 2024