Instrukcja obsługi Popp 009402


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Popp 009402 (4 stron) w kategorii Detektor dymu. Ta instrukcja była pomocna dla 19 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/4
1
Quick Start
This device is a combination of a Z Wave actuator. Please insert the Z Wave module -Wave sensor (smoke sensor) and a Z- -
including battery into the device housing first. Pressing the 'Z-Wave b includes and excludes the device. It supports secure utton'
communication.
Please refer to the chapters below for detailed information about all aspects of the products usage.
10- Year Smoke Detector
Manual
009402
2
Product Description
T - - -Wave module to form a wirelessly his product combines a certified '10 year' stand alone smoke detector with a plug in Z
reporting automatically meshing smoke sensor plus wirelessly controllable ’s sensor h is indoor siren. The smoke detector ead
certified label, DIN EN 14604 and satisfies all contemporary legal requirements.with the Q quality conforms
The High-End 10-y s smoke detector offers a test button conveniently accessible even with a broomstick when ear large mounted
on the sealing. The smoke chamber is monitored electronically to avoid any malfunction and wrong alerts. The device will also
report its e nd of life to make sure it is getting replaced on time.
Furthermore, the device can be used as an independent indoor siren within the Z-Wave network, which can alarm in case of
detected flood or burglary. Please consider that the additional siren function will influence ba ttery lifetime!
The smoke sensor Wave Z-and the controller communicate via a secure protocol to prevent manipulation.
Installation Guidelines
Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be
installed. The installation guide complies with the norm DIN EN 14676.
The first step is to mount the mounting base on the desired place in the home using screws.
Remove the battery isolation strip from the wireless module. The red LED will start blinking.
Include the Smoke Sensor into your existing Z- d Smart Home Network using the Z- Wave base Wave button.
Place the Smoke Detector on the mounting base and turn clockwise. Now the Smoke Detector is armed.
Battery Change: The battery of the wireless module will be empty much earlier than the 10 years soldered in battery of the
smoke s Detector, pull off the wireless module fr ensor. ensor. To replace the battery, remove the Smoke om the smoke s
Then you can replace the 1/2 AA battery and replug the wireless module.
Behavior within the Z- Wave Network
On factory default the device does not belong to any Z Wave network. The device needs to join an existing wireless network to -
communicate with the devices of this network. This process is called . Devices can also leave a network. This process Inclusion
is . Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned called Exclusion
into exclusion respective inclusion mode. Please refer to your primary controller’s manual on how to turn your controller into
inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the
network. Leaving the network .e. being excluded – i – sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion
of this device will fail. If the controller being included was a primary controller, it has to be reset first.
Pressing the Z- button includeWave s the device. If the button is pressed for at least 3 seconds, the inclusion will be done
withou . A single click on the button will exclude the device. t the Security Command Class
Operating the Device
In case smoke is detected by the smoke detector the device will sound and the wireless module will issue a Z-Wave alarm
command to the main controller and other associated devices. A low battery of the wireless module will be reported by the
wireless module. Please note that the battery level of the main dete t be replaced ctor is not reported since this battery can’
anyway. The end of life indicator serves the same purpose.- -
Outside
Inside
3
Note: All communication of the wireless module is performed with application level security if the device was included securely
and all communication partners support secure communication as well. In case a non-secure device is associated for switching
on smoke alarm, the smoke detector will detect this and change its communication style with this very device to non-secure.
This process happens one time and will take about 20 seconds. This delay will happen on first communication only.
Factory Reset
To reset the device keep the Wave LED starts flashing and after another 5 Z- button pushed for 10 seconds. After 5 seconds the
seconds there is a short beep signaling the successful reset back to factory defaults.
Firmware Update
Once the firmware update process has started double click the Z-Wave button to confirm firmware update process.
Alarm Messages
The device will issue the following (unsolicited) alarm messages:
Smoke Detected (this message will also be issued when the test button is pressed)
Low Battery Alarm (when the battery of the wireless modules goes low), indicated by yellow LED
Tamper Detected (ON, when the smoke detector head is removed from the base; OFF, when the detector head is
mounted to the base)
End of Life (issued, when the Detector Main Head has reached its end of life after 10+ years.)
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z- device. It Wave contains information about the device type and
the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node Information Frame. A simple click on the
Z- button sends a NIF. Wave
Associations
Z- -Wave devices control other Z Wave devices. The relationship between one device controlling another device is called
association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called and they are always related to certain events (e.g. button association groups
pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive a
common wireless command.
Association Groups
1
Lifeline (max. nodes in group: 4)
2
Alarm Reports (max. nodes in group: 4)
3
Switching Command when Alarm (max. nodes in group:4)
Configuration Parameters
Z- Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function
better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value
sent in the application shall be the desired value minus 256. For example: to set a parameter to 200 it may be needed to set a
value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may s
needed to be given as negative values, too.
Siren alarm sequence interval (Parameter: 1, Size: 1 ) byte
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly
off. This parameter defines the total length of the interval in seconds.
Value
Description
3 129-
Seconds (D efault 10)
Siren alarm tone length (Parameter: 2 : 1 byte), Size
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly
off. This parameter defines the total length of the sound versus silence within this interval.
Value
Description
1 - 99
Seconds (Default 8)


Specyfikacje produktu

Marka: Popp
Kategoria: Detektor dymu
Model: 009402

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Popp 009402, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Detektor dymu Popp

Popp

Popp 009402 Instrukcja

5 Lipca 2024

Instrukcje Detektor dymu

Najnowsze instrukcje dla Detektor dymu

First Alert

First Alert HD6135FB Instrukcja

14 Października 2024
Kidde

Kidde 3SFWR Instrukcja

9 Października 2024
Kidde

Kidde KF30R Instrukcja

9 Października 2024
Kidde

Kidde P4010ACS-WCA Instrukcja

9 Października 2024
Kidde

Kidde P4010DCSCO-WCA Instrukcja

9 Października 2024
Kidde

Kidde i12020CA Instrukcja

9 Października 2024
Kidde

Kidde i12040CA Instrukcja

9 Października 2024
Kidde

Kidde KF20R Instrukcja

9 Października 2024
Kidde

Kidde CP9000CA Instrukcja

9 Października 2024
Kidde

Kidde Pi2010CA Instrukcja

9 Października 2024