STANDARD EQUIPMENT
PXGTPS-0182
INSTRUCTION MANUAL
SPECIFICATIONS
Input Power: 18V x 2
Flow Rate Max.: 3000 l/h
Suction Height Max.: 8m
Delivery Height Max.: 26m
Delivery Pressure Max.: 2.6 bar
Water Temperature. 1 C - 35 C° °
Inlet & Outlet: 25mm (1”)
Noise Rating: 76 dB
Weight: 3.3kg
ozito.com.au
0720
Garden Transfer Pump
GARDEN
TRANSFER PUMP
IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY YOU
MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS
WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE
OUR CUSTOMER SERVICE HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL
NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER
SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND
ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE
WARRANTY POLICY OR PROCEDURE.
OZITO Australia/New Zealand (Head Ofce) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benets provided under this warranty are in addition to other rights and
remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to
a replacement or refund for a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also entitled to have the goods
repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this
warranty, however, where you have suffered any additional direct loss as a result of
a defective product you may be able to claim such expenses by contacting our
customer service helpline above.
WARNING
The following actions will result in the warranty being
void.
If the tool has been operated on a supply voltage other than that specied
on the tool.
If the tool shows signs of damage or defects caused by or resulting from
abuse, accidents or alterations.
Failure to perform maintenance as set out within the instruction manual.
If the tool is disassembled or tampered with in any way.
Professional, industrial or high frequency use.
5 YEAR REPLACEMENT WARRANTY
Your Product is guaranteed for a period of 60 months from the original date of
purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it
will be replaced in accordance with the terms of this warranty. Lithium Ion
batteries and chargers are covered by a 36 month
warranty and are excluded from the warranty extension. Warranty excludes
consumable parts, for example: O-rings, bearings, seals, gaskets .
BATTERY & CHARGER
This tool is compatible with all battery and chargers from the Ozito
Power X Change Range.
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to the
online manual.
1. Battery Cover
2. Carry Handle
3. Pump Setting Switch
4. Discharge Outlet
5. Priming Plug
6. Drain Plug
7. Suction Inlet
CORDLESS GARDEN TRANSFER PUMP
KNOW YOUR PRODUCT
1. INLET & OUTLET
SETUP & PREPARATION
1 2 3 4 5
6 7
WARNING!: ENSURE THE TOOL IS OFF AND THE
BATTERIES ARE REMOVED BEFORE PERFORMING
ANY OF THE FOLLOWING OPERATIONS.
1. Thread seal tape (not included) is
required on threads to ensure a
water tight seal and prevent any
leakage. Wind thread seal tape
clockwise on ttings.
Note: The input hose or pipe you are using must have a minimum diameter
of 25.4mm (1”).
Preparing the Pump: Your pump requires no assembly
before use other than the connection of a suitable inlet/
outlet hose and hose connections (not included).
2. Remove the plastic protection
cover from the suction inlet
and insert a 25.4mm ( 1”)
male threaded hose adaptor
(not included). Tighten rmly
with a spanner (not included).
3. Securely attach the input
hose or pipe to the other
end of the adaptor. Ensure
you have the correct
diameter hose or pipe that is
compatible with your water
drawing source.
WARNING!: ENSURE THE INPUT HOSE OR PIPE
IS NOT RESTRICTED IN ANY WAY.
Connecting Hose or Pipe to the Suction Inlet
Note: A leaking hose or pipe will draw in air and therefore not draw in any
water.
2. INSERTING & REMOVING THE BATTERIES
Connecting Hose or Pipe to the
Discharge Outlet.
1. Thread seal tape (not included) is
required on threads to ensure a water
tight seal and prevent any leakage. Wind
thread seal tape clockwise on ttings.
2. Remove the plastic protection
cover from the discharge
outlet and insert a 25.4mm
(1”) male threaded hose
adaptor (not included).
Tighten rmly with a spanner
(not included).
3. Securely attach the input
hose or pipe to the other
end of the adaptor. Ensure
you have the correct
diameter hose or pipe that is
compatible with your water
discharge application.
WARNING!: ENSURE THE DISCHARGE HOSE
OR PIPE IS NOT RESTRICTED IN ANY WAY AND
NOTHING IS OBSTRUCTING THE HOSE OR PIPE
WHEN THE PUMP IS IN OPERATION.
Note: The discharge hose or pipe you are using must have a minimum
diameter of 13mm (1/2”).
WARNING!: RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-
PROOF OR IF THEY ARE IMPROPERLY INSTALLED,
THE PRESSURE LINE COULD BURST DURING
OPERATION.
Inserting the Batteries
Always use 2 batteries of the same capacity and
charge state with the garden transfer pump.
1. Slide two batteries of the same capacity and same charge state into the
battery mount aligning the ribs so that they click into place.
Note: For best performance use only batteries which are charged to the
same level. Never combine full and half-full batteries as the equipment‘s
operating time depends on the battery with the lower charge level.
Removing the Batteries
1. Press and hold the battery release tab to release a battery and slide the
battery out.
PRESS

Specyfikacje produktu

Marka: Ozito
Kategoria: Pomp
Model: PXGTPS-0182

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Ozito PXGTPS-0182, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Pomp Ozito

Ozito

Ozito PTP-012A Instrukcja

15 Października 2024
Ozito

Ozito PFFP-65E Instrukcja

28 Sierpnia 2024
Ozito

Ozito PXGTPS-0182 Instrukcja

20 Sierpnia 2024

Instrukcje Pomp

Najnowsze instrukcje dla Pomp

MSW

MSW -AN-100 Instrukcja

15 Października 2024
MSW

MSW -MN34 Instrukcja

15 Października 2024
MSW

MSW -MN34M Instrukcja

15 Października 2024
MSW

MSW -AOP40S Instrukcja

15 Października 2024
Nefit

Nefit VentiLine Instrukcja

12 Października 2024
Liberty Pumps

Liberty Pumps 250 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 457 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps 230 Instrukcja

9 Października 2024
Liberty Pumps

Liberty Pumps CSP-257 Instrukcja

9 Października 2024