CONSTANT
PRESSURE
PUMP
800W
INSTRUCTION MANUAL
SPECIFICATIONS
Motor: 800W
Max. Flow Rate: 3,600 l/h
Max. Lift: 8m
Max. Head: 40m
Inlet: 25.4mm (1”BSP) Female
Outlet: 25.4mm (1“BSP) Male
Water Temp.: 1ºC to 35ºC
IP Rating: IPX4
Weight: 7.8kg
CPPAS-800
WHAT’S IN THE BOX
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: O-rings, bearing,
seals gaskets.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other
than that specified on the tool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the
instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
1220
Constant Pressure Pump
Teflon Tape
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
This constant pressure pump is designed for pumping clean water in
the house and garden. It is ideal for providing domestic water supply to
laundries, toilets and outdoor taps, combined with a trigger nozzle and
hose for garden watering and washing cars.
Your pump requires no assembly before use other than the connection
of suitable inlet/outlet hose or pipe adaptors (not included).
Positioning the pump
The device must be placed on a
horizontal, level surface that is
sufciently capable of supporting
the total weight of the device
when lled with water.
Note: The installation site must
be well ventilated and protected
from the effects of weather.
Note: When operating indoors
you must ensure that there is a drain in the oor or a mechanism to
prevent leakage.
1. Discharge outlet
2. Pump control unit
3. Carry handle
4. Control unit union
5. Priming plug
6. Pump body
7. Suction inlet
8. Base
9. Drain plug
CONSTANT PRESSURE PUMP
KNOW YOUR PRODUCT
1. SETTING UP
SETUP & PREPARATION
F EIRM BAS
WARNING!: ENSURE THE PUMP IS DISCONNECTED
FROM THE POWER SUPPLY BEFORE PERFORMING
ANY OF THE FOLLOWING OPERATIONS.
ACCESSORIES
10. Teon tape
1
8
9
10
4
5
6
7
3
2
Connecting to
the discharge outlet
1. Remove the plastic protection cover from
the discharge outlet.
2. Wrap the discharge outlet with Teon
tape.
3. Insert a 1” female threaded
adaptor (not included).
4. Securely attach the output hose
or pipe (not included) to the
other end of the adaptor. Ensure
you have the correct diameter
hose or pipe that is compatible
with your water discharge
application.
Note: The discharge hose or pipe
you are using must have a minimum
diameter of 19mm (3/4’’).
Note: Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump is in
operation.
Connecting to the suction inlet
1. Teon tape is required on threads to ensure
a water tight seal and prevent any leakage.
Wind Teon clockwise on ttings.
2. Remove the plastic protection cover
from the suction inlet.
3. Insert 1” male threaded adaptor
(not included). Tighten rmly with
a spanner (not included).
4. Securely attach the input hose or
pipe (not included) to the other end
of the adaptor. Ensure you have
the correct diameter hose or pipe
that is compatible with your water
drawing source.
Note: The suction pipe should have
an internal diameter of at least
25.4mm (1”); it must be kink resistant
and suitable for pump use. Ensure the
input hose or pipe is not restricted in any way.
2. SUCTION INLET 3. DISCHARGE OUTLET
WARNING!: RISK OF INJURY! IF THE COMPONENTS
ARE NOT COMPRESSION-PROOF OR IF THEY ARE
IMPROPERLY INSTALLED, THE PRESSURE LINE COULD
BURST DURING OPERATION.
Specyfikacje produktu
Marka: | Ozito |
Kategoria: | Przepych |
Model: | CPPAS-800 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Ozito CPPAS-800, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Przepych Ozito
15 Października 2024
16 Września 2024
14 Września 2024
11 Września 2024
28 Sierpnia 2024
20 Sierpnia 2024
5 Lipca 2024
Instrukcje Przepych
- Przepych Worx
- Przepych Milwaukee
- Przepych SilverCrest
- Przepych Simpson
- Przepych Toolcraft
- Przepych Kärcher
- Przepych Bestway
- Przepych Scheppach
- Przepych Ribimex
- Przepych Quigg
- Przepych Hazet
- Przepych Gardena
- Przepych Einhell
- Przepych Hyundai
- Przepych Makita
- Przepych Fuxtec
- Przepych Fiap
- Przepych RYOBI
- Przepych Polaris
- Przepych Hozelock
- Przepych Crivit
- Przepych Osram
- Przepych AL-KO
- Przepych Danfoss
- Przepych Güde
- Przepych Panduit
- Przepych Vaillant
- Przepych JANDY
- Przepych Zipper
- Przepych Grundfos
- Przepych Fluke
- Przepych Fluval
- Przepych Neptun
- Przepych Westfalia
- Przepych Hayward
- Przepych Ergotools Pattfield
- Przepych Lezyne
- Przepych Eheim
- Przepych Zehnder Pumpen
- Przepych Oase
- Przepych Michelin
- Przepych Blumfeldt
- Przepych Fieldmann
- Przepych PowerPlus
- Przepych Alpha Tools
- Przepych Vonroc
- Przepych Powerfix
- Przepych OKAY
- Przepych Metabo
- Przepych AstralPool
- Przepych Gre
- Przepych Enermax
- Przepych Blackburn
- Przepych Nefit
- Przepych Sicce
- Przepych Outwell
- Przepych Tacklife
- Przepych SKS
- Przepych Nibe
- Przepych Melinera
- Przepych Sanibroyeur
- Przepych Zodiac
- Przepych Topeak
- Przepych Bulex
- Przepych For_Q
- Przepych Abac
- Przepych Waldbeck
- Przepych Cannondale
- Przepych Coleman
- Przepych Maruyama
- Przepych Jabsco
- Przepych Eufab
- Przepych Pontec
- Przepych ESPA
- Przepych T.I.P.
- Przepych Velda
- Przepych Vivaria
- Przepych Plantiflor
- Przepych Verto
- Przepych Little Giant
- Przepych Wetelux
- Przepych Germania
- Przepych Anova
- Przepych DAB
- Przepych Esotec
- Przepych Wayne
- Przepych Rule
- Przepych Elpumps
- Przepych Hollex
- Przepych B-Air
- Przepych Baracuda
- Przepych Lifan
- Przepych Liberty Pumps
- Przepych BluGarda
- Przepych Madimack
- Przepych Sauermann
- Przepych Eco-Flo
- Przepych Nowax
- Przepych Zoeller
- Przepych Superior Pump
- Przepych SHURflo
- Przepych EvoHeat
- Przepych MSW
- Przepych Barwig
- Przepych Ebara
- Przepych Perlick
- Przepych Basement Watchdog
- Przepych Zéfal
- Przepych Comet
- Przepych Heissner
- Przepych OSIP
- Przepych Franklin Electric
Najnowsze instrukcje dla Przepych
15 Października 2024
15 Października 2024
15 Października 2024
15 Października 2024
15 Października 2024
12 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024