N219
CONTENTS
1 INSTALLATION PRECAUTIONS ............2
1-1 BEFORE INSTALLATION ................2
1-2 PARTS IDENTIFICATION ................3
1-3 KNOCKOUTS ..................................4
1-4 DETECTION AREA..........................5
1-5 DETERMINATION OF PIR
DETECTION LENGTH ....................5
2 INSTALLATION .......................................6
2-1 MOUNTING WITH BRACKET .........6
2-2 ADJUSTING THE VERTICAL
ANGLE.............................................8
2-3 MOUNTING WITHOUT
BRACKET ........................................9
2-4 WIRING .........................................10
2-5 WALL TAMPER (OPTION) ............11
3 WALK TEST ..........................................12
4 SETTING ..............................................13
5 AREA ADJUSTMENT ...........................16
6 LED INDICATION .................................17
7 SPECIFICATIONS ................................18
7-1 SPECIFICATIONS .........................18
7-2 DIMENSIONS ................................19
HX-40 2 PIRs standard model
HX-40AM HX-40 with anti-masking
HX-40DAM HX-40AM with micro-wave
3.0 m high mount detection area (12.0 m)
Unique pyro element
Intelligent AND logic
Dual signal processing logic
Vegetation sway analysis logic
Ideal detection area setting
Digital anti-masking (AM/DAM model only)
Microwave range selector (DAM model only)
•
•
•
•
•
•
•
•
NO.59-1501-3
INSTALLATION INSTRUCTIONS
High Mount
Outdoor Detector
HX-40/40AM/
40DAM
HX-40/40AM/
40DAM
High Mount
Outdoor Detector
- 1 -
1
INSTALLATION PRECAUTIONS
1-1
BEFORE INSTALLATION
Warning Failure to follow the instructions provided with this indication and improper
handling may cause death or serious injury.
Caution Failure to follow the instructions provided with this indication and improper
handling may cause injury and/or property damage.
The check mark indicates recommendation.
The nix sign indicates prohibition.
Warning Warning Caution
Do not repair or modify
product Keep product away from water Mount the unit securely
Mounting height Keep the detector parallel to the ground.
Consider the direction a person is approaching from, as well as the detection area.
Install the detector in a place where it is free from false alarm factors. For example:
Sunlight and reflection• Heat source• Objects moving in the wind •
Tilt
Parallel
2.5 m – 3.0 m
(8'2" – 9'10")
- 2 -
-Precautions for installing two or more sensors
HX-40
HX-40AM
HX-40DAM
Do not install two or more HX-40DAM’s units side-by-side or face-to-face. Instead, install them
back-to-back. If mounting on the same wall, be sure they are at least 1.0 m (3'3") apart from
each other.
1.0 m (3'3") or more Less than 1.0 m (3'3")
1-2
PARTS IDENTIFICATION
Screw kit
For joint For wall mounting For hood
Screw (4 × 20 mm) Screw (4 × 20 mm) Screw (3 × 10 mm)
*Lock screw attached on bracket base
Bracket base
Screw (3 × 10 mm)
Area masking seal
Main unit
Bracket
LED indicator
Lock screw* (M4 × 35 mm)
Lens
Base
PIR sensor
(Do not touch)
Terminals
Shaft cover
Cover
Lock screw
Hood
Anti-masking infrared LED
(HX-40AM/DAM only)
Microwave unit
(HX-40DAM
only)
(Do not touch)
Screw (4 × 20 mm)
- 3 -
Specyfikacje produktu
Marka: | Optex |
Kategoria: | Detektory ruchu |
Model: | HX-40DAM |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Optex HX-40DAM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Detektory ruchu Optex
16 Sierpnia 2024
15 Sierpnia 2024
13 Sierpnia 2024
7 Sierpnia 2024
6 Sierpnia 2024
6 Sierpnia 2024
6 Sierpnia 2024
4 Lipca 2024
Instrukcje Detektory ruchu
- Detektory ruchu TP-Link
- Detektory ruchu Philips
- Detektory ruchu SilverCrest
- Detektory ruchu Bosch
- Detektory ruchu Hikvision
- Detektory ruchu Theben
- Detektory ruchu Nedis
- Detektory ruchu Blaupunkt
- Detektory ruchu Speed-Link
- Detektory ruchu BTicino
- Detektory ruchu Honeywell
- Detektory ruchu Steinel
- Detektory ruchu Chamberlain
- Detektory ruchu DSC
- Detektory ruchu Schneider
- Detektory ruchu Perel
- Detektory ruchu Velleman
- Detektory ruchu Black Box
- Detektory ruchu Devolo
- Detektory ruchu Hama
- Detektory ruchu Marmitek
- Detektory ruchu Goobay
- Detektory ruchu Vemer
- Detektory ruchu Busch-Jaeger
- Detektory ruchu Technaxx
- Detektory ruchu Alecto
- Detektory ruchu EVE
- Detektory ruchu Smartwares
- Detektory ruchu Brennenstuhl
- Detektory ruchu Eminent
- Detektory ruchu KlikaanKlikuit
- Detektory ruchu ESYLUX
- Detektory ruchu Arlo
- Detektory ruchu Merten
- Detektory ruchu Chacon
- Detektory ruchu Konig
- Detektory ruchu Orbis
- Detektory ruchu Niko
- Detektory ruchu Gira
- Detektory ruchu HQ
- Detektory ruchu Berker
Najnowsze instrukcje dla Detektory ruchu
12 Stycznia 2025
10 Października 2024
6 Października 2024
4 Października 2024
3 Października 2024
29 Września 2024
24 Września 2024
22 Września 2024
17 Września 2024
18 Sierpnia 2024