Instrukcja obsługi Megger AVO210

Megger multimetr AVO210

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Megger AVO210 (20 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 5 osób i została oceniona przez 2 użytkowników na średnio 4.5 gwiazdek

Strona 1/20
mM
AVO210
Digital multimeter - Digitalmultimeter
Multimèter Numérique - Multímetro digitales
Digitale multimeter
User manual
Bedienungsanleitung
Manuel utilisateur
Guía del usuario
Gebruikershandleiding
www.megger.com2
G SAFETY INFORMATION
Understand and follow operating instructions carefully.
G WARNING
Do not use test leads or the multimeter if they are damaged
Do not use the multimeter if the tester is not operating properly
To reduce risk of fire and shock do not expose this product to rain or
any moisture
When using test leads or probes, keep fingers behind the finger guards.
Remove test leads from meter before opening the battery door or meter
case.
Use the meter only as specified in this manual or the protection by the
meter might be impaired.
Always use proper terminals, switch position, and range for measurements.
Never attempt a voltage measurement with the test lead inserted into the
A input terminal.
Verify the meter’s operation by measuring a known voltage. If in doubt,
have the meter serviced.
Do not apply more than the rated voltage, as marked on meter, between
terminals or between any terminal and earth ground.
Do not attempt a current measurement when the open voltage is above the
fuse protection rating.
Suspected open circuit voltage can be checked with voltage function.
Only replace the blown fuse with the proper rating as specified in this
manual.
Use caution with voltages above 30 Vac rms, 42 Vac peak , or 60 Vdc.
These voltages pose a shock hazard.
To avoid false readings that can lead to electric shock and injury, replace
battery as soon as low battery indicator appears.
Disconnect circuit power and discharge all high voltage capacitors before
testing resistance, continuity, diodes, or capacitance.
Do not use meter around explosive gas or vapour.
www.megger.com 3
G CAUTION
Disconnect the test leads from the test points before changing the position
of the function rotary switch.
Never connect a source of voltage with the function rotary switch
W , , d
, a
,
A, b position.
Do not expose Meter to extremes in temperature or high humidity.
Never set the meter in d a A function to measure the voltage of a
power supply circuit in equipment that could result in damage the meter
and the equipment under test.
Symbols as marked on the meter and instruction card
F Risk of electric shock
G See instruction card
d DC measurement
t Equipment protected by double or reinforced insulation
Battery
a AC measurement
c Conforms to EU directives
Maintenance
Do not attempt to repair this Meter. It contains no user-serviceable parts. Repair or
servicing should only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or
solvents.


Specyfikacje produktu

Marka: Megger
Kategoria: multimetr
Model: AVO210

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Megger AVO210, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje multimetr Megger

Megger

Megger AVO830 Instrukcja

21 Września 2024
Megger

Megger AVO835 Instrukcja

21 Września 2024
Megger

Megger AVO210 Instrukcja

20 Września 2024
Megger

Megger AVO410 Instrukcja

17 Września 2024

Instrukcje multimetr

Najnowsze instrukcje dla multimetr

Voltcraft

Voltcraft PMM 3005-20 Instrukcja

9 Października 2024
Bearware

Bearware 306998 Instrukcja

9 Października 2024
Bearware

Bearware 307001 Instrukcja

9 Października 2024
Fluke

Fluke 283 FC Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5330C Instrukcja

9 Października 2024
Noyafa

Noyafa NF-5310B Instrukcja

9 Października 2024
Emos

Emos M3216 Instrukcja

8 Października 2024
Uni-T

Uni-T UT121B Instrukcja

7 Października 2024
Maxwell

Maxwell MX-25103 Instrukcja

6 Października 2024
Velleman

Velleman DVM840 Instrukcja

5 Października 2024