MOBILE AIR CONDITIONING UNIT
LEVITA AC 12000
Maintenance and User's Manual
Caution!
Do not operate the device until you have read the operation and maintenance
manual! Keep this manual for future reference
07/2019 No. 796A
2
Thank you for buying this new mobile air conditioning unit. This user manual will help you
operate this device in a correct and safe way. We recommend that you take the necessary
time to read this manual and understand all the equipment operating functions. Use this
equipment only for private use and for the specified purposes. This equipment is not
intended for commercial use. Before use, read all the safety precautions carefully and keep
the manual for future use.
TABLE OF CONTENTS
SAFETY INSTRUCTIONS ........................................................................................... 3
CHARACTERISTICS AND EQUIPMENT ...................................................................... 6
TECHNICAL DATA ..................................................................................................... 7
OPERATION AND SETTINGS ..................................................................................... 8
Control panel and remote control description .................................................. 8
Installation and positioning ............................................................................. 10
Drainage instructions ...................................................................................... 12
MAINTENANCE .................................................................................................... 14
STORAGE ............................................................................................................... 14
TROUBLESHOOTING ............................................................................................. 15
EQUIPMENT DISPOSAL .......................................................................................... 16
WARRANTY CONDITIONS ...................................................................................... 16
REPAIRS ............................................................................................................... 16
WIRING DIAGRAM ................................................................................................. 16
EC DECLARATION OF CONFORMITY .................................................................... 17
Environment-friendly coolant R290 is used in mobile air-conditioning units. The R290 coolant
is odourless and does not contain ozone compared with the other alternatives and has very
little impact on the environment.
Read this manual carefully before any use, maintenance or repair.
The illustrations in this user manual may not correspond in all details to the actual product
design. Please pay attention to the current product design.
3
SAFETY INSTRUCTIONS
This appliance may be used by children aged 8 years or above and by persons with reduced
physical, sensory or mental abilities or lack of experience and knowledge if they are
supervised or instructed in the safe use of the appliance and understand the possible
hazards. Children should not play with the equipment. Children should not perform cleaning
or user-level maintenance without supervision.
1. Do not use any other means than those specified in this operating manual to accelerate
defrosting and cleaning.
2. This device must not be stored in areas with permanent sources of ignition (e.g. open
fire, gas or electric heating equipment in operation).
3. Do not pierce or expose the equipment to an open fire.
4. Note that the coolant may be odourless.
5. This equipment should be installed, operated and stored in a space with a floor area
larger than 11 m2.
6. Keep all vents unobstructed.
7. The service must only be performed according to the manufacturer instructions.
8. This device must be stored in a well-ventilated area, the dimensions of which
correspond to the dimensions specified for the operation of the equipment.
9. Only persons with a valid authorisation issued by a competent accredited authority who
demonstrate their competence to handle coolants safely in accordance with the
applicable regulations may work or interfere with the coolant circuit.
10. The service must only be performed according to the equipment manufacturer
instructions.
Maintenance and repairs requiring the participation of other qualified persons must be
carried out under the supervision of a person authorised to handle flammable
refrigerators.
11. All working procedures that affect safety elements must be performed only by
authorised persons.
Notes:
1. This air conditioning unit is intended for indoor use only. It is not suitable for any other
use.
2. When installing the air conditioning unit, observe local rules for connection to the mains
and ensure proper grounding. If you have any doubts about the electrical installation,
follow the manufacturer’s instructions and, if necessary, have it carried out by a
qualified electrician.


Specyfikacje produktu

Marka: Levita
Kategoria: Klimatyzator - Chłodnica powietrza
Model: AC 12000

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Levita AC 12000, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Klimatyzator - Chłodnica powietrza Levita

Levita

Levita AC 12000 Instrukcja

27 Września 2024

Instrukcje Klimatyzator - Chłodnica powietrza

Najnowsze instrukcje dla Klimatyzator - Chłodnica powietrza