High-performance blade server optimized for virtualization
Please see the Legal Information section for important notices and information. 1.
Product Guide
October 2010
IBM BladeCenter HS22V
Product Overview
CONTENTS
Product Overview 1
Selling Features 2
Key Features
4
Key Options 1
4
HS22V Images 16
HS22V Specifications 16
The Bottom Line 19
Server Comparison 20
For More Information 21
Legal Information 21
High density, high performance 2-socket blade server optimized for
virtualization
Suggested uses: Mainstream virtualization and memory-intensive HPC applications requiring
high memory density, outstanding performance, and enhanced power efficiency.
Today’s data center environment is tougher than ever. You’re looking to reduce IT cost,
complexity, space requirements, energy consumption and heat output, while increasing flexibility,
utilization and manageability through virtualization. Incorporating IBM X-Architecture
features,
the IBM® BladeCenter® HS22V blade server, combined with the various BladeCenter chassis,
can help you accomplish all of these goals.
Reducing an entire server into as little as .5U of rack space (i.e., up to 14 servers in 7U) does not
mean trading away features and capabilities for smaller size. Each HS22V blade server offers
features comparable to many 1U rack-optimized full-featured servers: The HS22V supports up to
two of the latest high-performance 6-core/4-core/2-core Intel
® Xeon® 5600 series and 5500
series processors. The Xeon processors are designed with up to 12MB of shared cache and
leading-edge memory performance (up to 1333MHz, depending on processor model) to help
provide the computing power you require to match your business needs and growth. The HS22V
supports up to 288GB1 of registered double data rate III (DDR3) ECC (Error Checking and
Correcting) memory in 18 DIMM slots, with optional Chipkill
protection
2, for high performance
and reliability. Selected models are planned for NEBS-3/ETSI-compliance.
The HS22V supports VMware vSphere Hypervisor (formerly ESXi) preloaded on a standard
USB flash drive. It operates in a diskless configuration, offers a smaller memory footprint,
extremely high performance, and stronger security, making getting a system up and running in a
virtualized environment faster and easier than ever before. The HS22V supports approximately
50% more average virtual machines (VMs) than the HS22. With up to 288GB of memory, the
HS22V is an outstanding choice for virtualization, in-memory databases, and memory-intensive
enterprise applications.
An integrated dual-port Gigabit Ethernet
3 controller is standard, providing high-speed data
transfers and offering TOE (TCP Offload Engine) support, load-balancing and failover
capabilities. Via optional expansion cards, each blade can also connect to additional Ethernet,
10Gb Ethernet, Converged Network Adapter (CNA), SAS, Fibre Channel, iSCSI, InfiniBand
™,
and other high-speed communication switches housed in the chassis. This blade is designed with
power management capability to provide the maximum uptime possible for your systems. In
extended thermal conditions or power brownouts, rather than shut down completely, or fail, the
HS22V automatically reduces the processor frequency to maintain acceptable thermal and power
levels.
All HS22V models offer impressive features at an equally impressive price, including up to two
1.8-inch fixed solid-state drives (SSDs) with RAID-0/1 support, and one internal USB flash
drive (for embedded hypervisor]. Additional direct-attach storage is available via the BladeCenter
S chassis. Moreover, the HS22V is optimized for diskless operation, offering each blade server
access to essentially unlimited external storage capacity via Fibre Channel, SAS, or iSCSI.
A single BladeCenter E BladeCenter H or chassis supports up to 14 hot-swappable 30mm-
wide HS22V blades in only 7U (BladeCenter E) or (BladeCenter H) of rack space or up to 9U 12
in the 12U BladeCenter HT high-speed telecommunications chassis. In addition to the blade
servers, these chassis also hold up to 4 switches (BladeCenter E) or up to 10 (BladeCenter H) or
8 switches/bridges (BladeCenter HT) internally. The BladeCenter S, designed for SMB and
mid-market customers, takes integration and affordability to a new level, combining up to 12 hot-
swap SAS/SATA HDDs (with optional SAS card) and up to 6 blade servers and 4 switches. Not
only can this save significant data center space (and therefore the cost of floor space and rack
1 When 16GB DIMMs are available in 4Q/10.
2 Chipkill protection on the HS22V requires x4 DIMMs; Chipkill protection is not available with x8 DIMMs.
3 Actual data transfer speed will vary and is often less than the maximum possible. Gigabit Ethernet transfer speed requires support on both
system and server, and appropriate network infrastructure.
High-performance blade server optimized for virtualization
Please see the Legal Information section for important notices and information. 2.
hardware) compared to 1U servers, it also consolidates switches/bridges and cables for reduced
complexity and lower cabling costs, and it allows clients to manage everything in the solution as
one. Using a BladeCenter E chassis, up to 84 HS22V servers (168 processors) can be installed in
one industry-standard 42U rack; but the value of BladeCenter extends far beyond high density
data center environments.
The various BladeCenter chassis are designed to monitor environmental conditions in the chassis
and each blade and send alerts to the administrator. Advanced standard features, such as Active
Memory, , Predictive Failure Analysis, light path diagnostics hot-swap redundant hard
disk drives, power supplies and blower modules Calibrated Vectored Coolingwith ; IPMI
2.0 support, including highly secure remote power control; text-console redirect over LAN,
next-generation BIOS (UEFI), an Advanced Management Module (upgradeable with a
redundant AMM), IBM Systems Director management software including IBM Systems
Director Active Energy Manager™. Remote Deployment Manager and IBM ServerGuide
help maintain system availability with increased uptime.
If you need highly manageable, high-performance virtualization in a space- or power-constrained
environment, the HS22V is the ideal system.
Selling Features Price/Performance
There is an HS22V model to fit all budgets. The HS22V offers a choice of high-performance 6-core/4-
core/2-core Xeon processors with integrated memory controllers, clock rates from 1.86GHz to
3.46GHz 12MB, and up to shared cache (processor-specific) of integrated Level 3 cache. Xeon 5600
series processors offer up to 60% better performance
4 than the previous-generation 5500 series
processors and up to 1,500% better performance than the single-core processors of a few years ago
that you may still be using.
Low-voltage processors draw less energy and produce less waste heat than higher-voltage
processors, thus helping to reduce data center energy costs. On a per-core basis, the standard 80W
processors are extremely economical, consuming as little as 13.33W per core. Some low-voltage
Xeon processors consume only 40W (10W per core).
Up to 288GB of registered DDR3 ECC memory operates at 800MHz to 1333MHz (depending on the
system configuration), for high performance and wide memory bandwidth.
Run two DIMMs per memory channel (2DPC) at 1333MHz in 5600 series processor configurations
Embedded virtualization (optional on all models) offers extremely high performance, enhanced
security, and a zero-gigabyte HDD footprint. (In other words, no mechanical HDD to fail.)
Solid state drives (SDDs) use only 2W of energy per drive, vs. 9-10W for 2.5-inch HDDs. This is as
much as 80% less energy than a HDD would use (with a corresponding reduction in heat output).
Low power 1.35 volt memory draws up to 15% less power than current shipping memory DIMMs.
Selected HS22V blade servers are planned for NEBS3/ETSI-compliance and feature long-life
availability. These blades are ideal for telecom or Next Generation Network (NGN) applications such
as IPTV, IP Multimedia Subsystem (IMS) and security.
The extremely high degree of integration in the various BladeCenter chassis reduces the need for
server components, replacing numerous fans, KVM and Ethernet cables, power supplies, external
switches and other components with fewer shared hot-swap/redundant components in the
BladeCenter chassis itself. This integration also can greatly reduce the amount of power consumed
and heat produced, relative to an equivalent number of 1U servers. This can significantly reduce a
data center power bill. The reduced data center footprint can also save on infrastructure cost.
The midplanes used in all chassis provide high-speed blade-to-blade, blade-to-switch-module
and module-to-module communications internally as well as externally. The midplanes used in the
BladeCenter H and BladeCenter HT chassis provide four 10Gb data channels to each blade, and
supports high-speed switch modules, including 4X InfiniBand and 10Gb Ethernet.
The various BladeCenter chassis use ultrahigh efficiency power supplies. Most industry-standard
servers use power supplies that are between 70-75% efficient at converting power from AC wall
current to the DC power used inside servers. BladeCenter power modules are up to 92% efficient.
This helps save even more money, as more of the power input you are paying for is used for
processing, rather than released into the data center as waste heat that requires even more energy to
cool.
BladeCenter also reduces the number of parts required to run the system. Sharing fans, systems
management, floppy devices and media means fewer parts to buy and maintain, and fewer items that
can fail and bring the overall solution down.
Flexibility
The HS22V has the ability to grow with your application requirements, thanks to:
4 Based on Intel measurements.
High-performance blade server optimized for virtualization
Please see the Legal Information section for important notices and information. 3.
Up to two multi-core Xeon processors (up to twelve cores per server).
A choice of processor speeds from 1.86 to 3.46GHz, up to 12MB of shared cache, and a choice of
power draw from 40W to 130W.
A choice of memory speeds from 800MHz to 1066MHz or 1333MHz.
Up to 288GB of system memory in 18 DIMM slots.
Up to two internal hot-swap 1.8-inch solid state drives, and access to terabytes of external storage
via the BladeCenter S chassis or IBM System Storage
SAN and NAS storage devices. SSDs
consume only 10-20% of the energy required by 2.5-inch HDDs.
Two Gigabit Ethernet ports standard, plus optional 2-port or 4-port expansion cards or a
BladeCenter PCI Express I/O Expansion Unit 3. In addition, the various BladeCenter chassis
offer a high degree of flexibility:
A 30mm HS22V blade server can be upgraded, via the PCI Express I/O Expansion Unit 3. This
expandability allows configurations that are 30mm or 60mm wide, with a variety of I/O options,
depending on need.
When installed in a BladeCenter H high-speed switch bay, the optional Multi-Switch Interconnect
Module doubles the number of Gigabit Ethernet and Fibre Channel connections to every blade in
the chassis (up to 8 or 12 ports, depending on the blade server).
Xeon processor-based HS22V blades can be used in the same chassis as Intel processor-based
HC10 HS20 HS21, HS12, , , HS21 XM, HS22, HS40 HX5, and blades; AMD Opteron processor-
based LS20, LS21, LS22, LS41 and LS42 blades; IBM PowerPC® processor-based JS20 JS21, ,
and JS22 blades; POWER6® processor-based JS12, JS23, JS43 and Express blades; POWER7®
processor-based PS700, PS701, and PS702 blades; Cell Broadband Engine processor-based
QS21; and IBM PowerXCell™ processor-based QS22 blades. Depending on the blade servers used,
the various BladeCenter chassis support Microsoft
® Windows®, Linux®, Novell Netware, IBM AIX
®
and Sun Solaris 10 operating systems in the same chassis.
Most HS/LS/JS/QS blade servers ever released by IBM are supported in every BladeCenter chassis
ever released, going back to 20025. Every switch module released by IBM is equally compatible. (Ask
HP and Dell how far back their compatibility goes.)
A blade server has access to as many as 10 communication switches/bridges in a BladeCenter H
or 8 in a BladeCenter HT chassis. (Up to 4 switches in a BladeCenter E, S, or T chassis.) And the
switches can be Ethernet, iSCSI, SAS, InfiniBand, Fibre Channel, or anything else designed and
ServerProven® for BladeCenter use. Switches, bridges and interface cards are currently available
from such vendors as Brocade, Cisco, Intel, McData, Nortel, QLogic, Cisco Topspin and others, in
addition to IBM.
Manageability
The HS22V blade server includes an Integrated Management Module (IMM) to monitor server
availability, perform Predictive Failure Analysis, etc., and trigger IBM Systems Director alerts. The
IMM performs the functions of both the Baseboard Management Controller (BMC) of earlier systems,
and the Remote Supervisor Adapter II, as well as remote presence/cKVM.
Each BladeCenter chassis includes an Advanced Management Module to provide additional
systems management capabilities, including Web-based out-of-band control; virtual floppy and CD-
ROM support; latest OS failure screen capture; LDAP and SSL support; and remote redirection of
video, text, keyboard and mouse.
Integrated industry-standard Unified Extensible Firmware Interface (UEFI) next-generation BIOS.
New capabilities include:
Human readable event logs; no more beep codes
Complete setup solution by allowing adapter configuration function to be moved into UEFI
Complete out-of-band coverage by the Advance Settings Utility to simplify remote setup
Integrated industry-standard IPMI 2.0 support works with the IMM to alert IBM Systems Director to
anomalous environmental factors, such as voltage and thermal conditions. It also supports highly
secure remote power control.
Integrated Trusted Platform Module (TPM) 1.2 support.
IBM Systems Director Active Energy Manager, an IBM-exclusive, is designed to take
advantage of new system power management features, by monitoring actual power usage and
providing power consumption capping features. More accurate power usage data helps with data
center construction planning and the sizing of power and cooling needs, as well as allowing you to
use available power more efficiently.
The HS22V supports and remote presence/concurrent KVM (cKVM) concurrent media (cMedia)
5 Some older chassis may require power module and management module upgrades. But the chassis itself, as well as fan/blower modules
and other components, are fully compatible.


Specyfikacje produktu

Marka: Lenovo
Kategoria: serwer
Model: eServer BladeCenter HS22V
Wysokość produktu: 29 mm
Szerokość produktu: 245 mm
Głębokość produktu: 446 mm
Waga produktu: 5440 g
Certyfikat środowiskowy (zrównoważonego rozwoju): ENERGY STAR
Zgodny z Mac: Nie
Ilość portów Ethernet LAN (RJ-45): 2
Taktowanie procesora: 3.2 GHz
Typ procesora: Intel® Xeon® z serii 5000
Model procesora: X5672
Karta graficzna: G200eV
Liczba portów USB 2.0: 1
Przewodowa sieć LAN: Tak
Usługa RAID: Tak
Producent procesora: Intel
Liczba rdzeni procesora: 4
Typ pamięci wewnętrznej: DDR3-SDRAM
Pamięć wewnętrzna: 12 GB
Obudowa: Ostrze
Ilość jednostek zasilania: 1
Maksymalna pojemność pamięci: 288 GB
Gniazdo procesora: Socket B (LGA 1366)
Procesor: Intel® Xeon®
Układ płyty głównej: Intel® 5520
Poziomy raid: 0, 1
PCI Express x16 gniazda: 2
Maksymalna liczba procesorów SMP: 2
Liczba obsługiwanych HDD: 2
Kontroler LAN: Broadcom BCM5709S
Funkcja Wake-On-LAN: Tak
Cechy sieci: Gigabit Ethernet
Zgodny ze standradami przemysłowymi: IEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Rodzina adaptera graficznego: Matrox
Korekcja ECC: Tak
Pamięć karty graficznej podsystemu graficznego: 16 MB
Gniazda pamięci: 18x DIMM
Rozmiar HDD: 1.8 "
Całkowita pojemność przechowywania: 0 GB
Procesor ARK ID: 52579
Technologia Intel® Hyper Threading (Intel® HT Technology): Tak
Technologia Intel® Turbo Boost: 1.0
Technologia Intel® Quick Sync Video: Nie
Technologia Intel® InTru™ 3D: Nie
Technologia Intel® Clear Video HD (Intel® CVT HD): Nie
Nowe instrukcje AES (Intel® AES-NI): Tak
Technologia Udoskonalona Intel SpeedStep: Tak
Technologia Intel® Trusted Execution: Tak
Maksymalna konfiguracja CPU: 2
Intel® Enhanced Halt State: Tak
Intel® Clear Video Technology dla MID (Intel® CVT for MID): Nie
Intel® VT-x with Extended Page Tables (EPT): Tak
Intel® 64: Tak
Technologia Wirtualizacji Intel® (Directed I/O) (VT-d): Tak
Technologia Intel® Clear Video: Nie
Technologia virtualizacji Intel® (VT-x): Tak
Interfejs HDD: SATA
Maksymalna pojemność przchowywania: 0.1 TB
Liczba procesorów: 1
Typ pamięci procesora: Smart Cache
Cache procesora: 12 MB
Wskaźnik magistrali systemowej: 6.4 GT/s
Maksymalne taktowanie procesora: 3.6 GHz
Litografia procesora: 32 nm
Liczba wątków: 8
Tryb pracy procesora: 64-bit
Nazwa kodowa procesora: Westmere EP
Maksymalna pamięć wewnętrzna wspierana przez procesor: 288 GB
Typy pamięci wspierane przez procesor: DDR3-SDRAM
Taktowanie zegara pamięci wspierane przez procesor: 800,1066,1333 MHz
Przepustowość pamięci obsługiwana przez procesor ( max ): 32 GB/s
Kanały pamięci wspierane przez procesor: Potrójny
Pamięć ECC wspierana przez procesor: Tak
Termiczny układ zasilania (TDP): 95 W
Bezkonfliktowy procesor: Nie
Stepping: B1
Instrukcje obsługiwania: SSE4.2
Kod procesora: SLBYK
Technologia Execute Disable Bit (EDB): Tak
Stan spoczynku: Tak
Technologie Thermal Monitoring: Nie
Wbudowane opcje dostępne: Nie
Typ magistrali: QPI
Wielkość opakowania procesora: 42.5 X 45 mm
Układ pamięci: 3 x 4 GB
Prędkość zegara pamięci: 1066 MHz
Obsługa zasilania zapasowego (RPS): Nie
Parytet FSB: Nie
Tcase: 82.9 °C
Magistrala systemowa: 1333 MHz
Seria procesora: Intel Xeon 5600 Series
Intel® Wireless Display (Intel® WiDi): Nie
Technologia Intel® My WiFi (Intel® MWT): Nie
Technologia Intel® Anti-Theft (Intel® AT): Nie
Intel® Insider™: Nie
Technologia Intel® FDI: Nie
Intel® Flex Memory Access: Nie
Intel® Fast Memory Access: Nie
Intel® Demand Based Switching: Tak
Technologia Intel® Dual Display Capable: Nie
Intel® Rapid Storage Technology: Nie
Napędy optyczne: Nie
Współczynnik Magistrala/Rdzeń: 24
Physical Address Extension (PAE): Tak
Rozszerzenie PAE (Physical Address Extension): 40 bit
Liczba linków QPI: 2
Kontroler tablicy dysku: LSI Logic 53C1046E